• Availability & Price
  • Search SKU
Filter by attributes
  • Coil Type
  • Flow Factor 1 (Cv)
  • Maximum Pressure Differential (psi)
  • Orifice 1 Size (inch)
  • Power (Watts)
  • Seal Material
  • Voltage (V)
More Filters...
Filter by manufacturer
Manufacturers

Parker 2-Way Normally Open, 1/4" NPT General Purpose Solenoid Valves

Picture for category Parker 2-Way Normally Open, 1/4" NPT General Purpose Solenoid Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's 2-Way Normally Open 1/4" NPT Solenoid Valves are used in a wide variety of applications ideally suited for general purpose air, liquids, gases and steam. These valves are available in brass and stainless steel construction. Coil options are available in 1/2" NPT Conduit and DIN Form A in Class F and H or NEMA 4X, 7 or 9 specification.

Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation

Features/ Benefits:
• High Quality Standards of Skinner® and Gold Ring™ Brand
• Modular Design
• Long Life
• Tight Shutoff

Applications:
• Instrumentation Equipment
• Analyzers and Diagnostic Equipment
• Medical and Dental Equipment
• Portable Welding Equipment
• Spraying Equipment
• Lubrication Equipment
• Beverage Dispensing & Vending machines
• Oil Burners
• Humidification and Misting Equipment
• Mobile Fuel Shut Off
• Textile and Dry Cleaning Equipment
• Commercial Dishwashers
• Commercial Laundry and Dryers
• Air Horns
• Pneumatic Fan Clutch
• Irrigation Equipment

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMPort TypePort SizeBody MaterialDivisionMediaFunctionCoil TypeValve TypeInput VoltageSeal MaterialActuation TypeOrifice 1 SizeOrifice 2 SizeProduct SeriesNumber of PortsPower ConsumptionFlow Coefficient 1Flow Coefficient 2Coil Specifications MetMaximum Fluid TemperatureMinimum Fluid TemperatureMaximum Pressure DifferentialMinimum Pressure DifferentialCoil TypeVoltage (V)Power (Watts)Seal MaterialFlow Factor 1 (Cv)Orifice 1 Size (inch)Maximum Pressure Differential (psi)
04F20O2118ACF4C15
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way220/50 to 240/60NBRDirect Acting9/32n/aGold Ring Series211 W (AC)0.96n/aClass F180030 psi (AC)01/2" NPT Conduit, 18" Leads, Class F, NEMA 4X220/50-240/6011 Watt (AC)NBR0.969/3230 psi (AC)
04F20O2118ACFPH01
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)DIN Form A, Class F2-Way24/60NBRDirect Acting9/32n/aGold Ring Series211 W (AC)0.96n/aClass F180030 psi (AC)0DIN Form A, Class F24/6011 Watt (AC)NBR0.969/3230 psi (AC)
04F20O2118ACFPH05
Quote Required
$207.17
EANPT1/4 inchBrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)DIN Form A, Class F2-Way110/50-120/60NBRDirect Acting9/32 inchn/aGold Ring Series211 W (AC)0.96 Cvn/aClass F180 °F0 °F30 psi (AC)0 psiDIN Form A, Class F110/50-120/6011 Watt (AC)NBR0.969/3230 psi (AC)
04F20O2118ACFPH15
Quote Required
TBD
NPT1/4 inchBrassFluid Control DivisionLiquids and GasesNormally Open (NO)DIN Form A, Class F2-Way220/50 to 240/60NBRDirect Acting9/32 inchn/aGold Ring Series211 W (AC)0.96 Cvn/aClass F180 °F0 °F30 psi (AC)0 psiDIN Form A, Class F220/50-240/6011 Watt (AC)NBR0.969/3230 psi (AC)
7122KBN2LF00N0C111C1
Quote Required
TBD
NPT1/4 inchBrassFluid Control DivisionLiquids and GasesNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way12.0 VDCPCTFEDirect Acting3/32 inchn/a7000 Series210 W (DC)0.21 Cvn/aNEMA 4X165 °F0 °F175 psi (DC)0 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X12 VDC10 Watt (DC)PCTFE0.213/32175 psi (DC)
7122KBN2LF00N0C111C2
Quote Required
TBD
NPT1/4 inchBrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way24.0 VDCPCTFEDirect Acting3/32 inchn/a7000 Series210 W (DC)0.21 Cvn/aNEMA 4X165 °F0 °F175 psi (DC)0 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X24 VDC10 Watt (DC)PCTFE0.213/32175 psi (DC)
7122KBN2LF00N0C111P3
Quote Required
$0.01
EANPT1/4 inchBrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way110/50-120/60PCTFEDirect Acting3/32 inchn/a7000 Series210 W (AC)0.21 Cvn/aNEMA 4X165 °F0 °F175 psi (AC)0 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X110/50-120/6010 Watt (AC)PCTFE0.213/32175 psi (AC)
7122KBN2LF00N0C222C1
Quote Required
TBD
NPT1/4 inchBrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way12.0 VDCPCTFEDirect Acting3/32 inchn/a7000 Series210 W (DC)0.21 Cvn/aNEMA 4X165 °F0 °F175 psi (DC)0 psi1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X12 VDC10 Watt (DC)PCTFE0.213/32175 psi (DC)
7122KBN2LF00N0C222C2
Quote Required
TBD
NPT1/4 inchBrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way24.0 VDCPCTFEDirect Acting3/32 inchn/a7000 Series210 W (DC)0.21 Cvn/aNEMA 4X165 °F0 °F175 psi (DC)0 psi1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X24 VDC10 Watt (DC)PCTFE0.213/32175 psi (DC)
7122KBN2LF00N0D100C2
Quote Required
$177.89
EANPT1/4 inchBrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)DIN Form A, Class F2-Way24.0 VDCPCTFEDirect Acting3/32 inchn/a7000 Series210 W (DC)0.21 Cvn/aClass F165 °F0 °F175 psi (DC)0 psiDIN Form A, Class F24 VDC10 Watt (DC)PCTFE0.213/32175 psi (DC)
7122KBN2LF00N0H111C2
Quote Required
$0.01
EANPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 92-Way24.0PCTFEDirect Acting3/32n/a7000 Series210 W (DC)0.21n/aNEMA 91650175 psi (DC)01/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 924 VDC10 Watt (DC)PCTFE0.213/32175 psi (DC)
7122KBN2LF00N0H111P3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 92-Way110/50-120/60PCTFEDirect Acting3/32n/a7000 Series210 W (AC)0.21n/aNEMA 91650175 psi (AC)01/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9110/50-120/6010 Watt (AC)PCTFE0.213/32175 psi (AC)
73222BN2MN00N0C111C1
Quote Required
TBD
NPT1/4 inchBrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way12.0 VDCNBRManual7/16 inchn/a7000 Series210 W (DC)0.76 Cvn/aNEMA 4X185 °F0 °F200 psi (DC)5 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X12 VDC10 Watt (DC)NBR0.767/16200 psi (DC)
73222BN2MN00N0C111C2
Quote Required
TBD
NPT1/4 inchBrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way24.0 VDCNBRMechanical7/16 inchn/a7000 Series210 W (DC)0.76 Cvn/aNEMA 4X185 °F0 °F200 psi (DC)5 psi1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X24 VDC10 Watt (DC)NBR0.767/16200 psi (DC)
73222BN2MN00N0C111P3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way110/50-120/60NBRManual7/16n/a7000 Series210 W (AC)0.76n/aNEMA 4X1850200 psi (AC)51/2" NPT Conduit, 18" Leads, Class F, NEMA 4X110/50-120/6010 Watt (AC)NBR0.767/16200 psi (AC)
73222BN2MN00N0C111Q3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way220/50 to 240/60NBRManual7/16n/a7000 Series210 W (AC)0.76n/aNEMA 4X1850200 psi (AC)51/2" NPT Conduit, 18" Leads, Class F, NEMA 4X220/50-240/6010 Watt (AC)NBR0.767/16200 psi (AC)
73222BN2MN00N0C222C1
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way12.0NBRManual7/16n/a7000 Series210 W (DC)0.76n/aNEMA 4X1850200 psi (DC)51/2" NPT Conduit, 18" Leads, Class H, NEMA 4X12 VDC10 Watt (DC)NBR0.767/16200 psi (DC)
73222BN2MN00N0C222C2
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way24.0NBRManual7/16n/a7000 Series210 W (DC)0.76n/aNEMA 4X1850200 psi (DC)51/2" NPT Conduit, 18" Leads, Class H, NEMA 4X24 VDC10 Watt (DC)NBR0.767/16200 psi (DC)
73222BN2MN00N0C222P3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way110/50-120/60NBRManual7/16n/a7000 Series210 W (AC)0.76n/aNEMA 4X1850200 psi (AC)51/2" NPT Conduit, 18" Leads, Class H, NEMA 4X110/50-120/6010 Watt (AC)NBR0.767/16200 psi (AC)
73222BN2MN00N0C222Q3
Quote Required
TBD
NPT1/4BrassFluid Control DivisionGeneral Purpose for AirNormally Open (NO)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way220/50 to 240/60NBRManual7/16n/a7000 Series210 W (AC)0.76n/aNEMA 4X1850200 psi (AC)51/2" NPT Conduit, 18" Leads, Class H, NEMA 4X220/50-240/6010 Watt (AC)NBR0.767/16200 psi (AC)