Parker 2-Way Normally Closed, 3/8" NPT General Purpose Solenoid Valves

Picture for category Parker 2-Way Normally Closed, 3/8" NPT General Purpose Solenoid Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's 2-Way Normally Closed 3/8" NPT Solenoid Valves are used in a wide variety of applications ideally suited for general purpose air, liquids, gases and steam. These valves are available in brass and stainless steel construction. Coil options are available in 1/2" NPT Conduit and DIN Form A in Class F and H or NEMA 4X, 7 or 9 specification.

Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation

Features/ Benefits:
• High Quality Standards of Skinner® and Gold Ring™ Brand
• Modular Design
• Long Life
• Tight Shutoff

Applications:
• Instrumentation Equipment
• Analyzers and Diagnostic Equipment
• Medical and Dental Equipment
• Portable Welding Equipment
• Spraying Equipment
• Lubrication Equipment
• Beverage Dispensing & Vending machines
• Oil Burners
• Humidification and Misting Equipment
• Mobile Fuel Shut Off
• Textile and Dry Cleaning Equipment
• Commercial Dishwashers
• Commercial Laundry and Dryers
• Air Horns
• Pneumatic Fan Clutch
• Irrigation Equipment

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMPort TypeBody MaterialDivisionMediaFunctionCoil TypeValve TypeInput VoltageSeal MaterialActuation TypeOrifice 1 SizeOrifice 2 SizeProduct SeriesNumber of PortsPower ConsumptionFlow Coefficient 1Flow Coefficient 2Coil Specifications MetMaximum Fluid TemperatureMinimum Fluid TemperatureMaximum Pressure DifferentialPort SizeMinimum Pressure DifferentialBody MaterialCoil TypeVoltage (V)Power (Watts)Seal MaterialFlow Factor 1 (Cv)Orifice 1 Size (inch)Maximum Pressure Differential (psi)
06F25C2122CAFPH15
Quote Required
TBD
NPTBrassFluid Control DivisionLiquids and GasesNormally Closed (NC)DIN Form A, Class F2-Way220/50 to 240/60NBRDiaphragm11/32 inchn/aGold Ring Series26 W (AC)1.2 Cvn/aClass F180 °F0 °F300 psi (AC)3/8 inch5 psiBRASSDIN Form A, Class F220/50-240/606 Watt (AC)NBR1.211/32300 psi (AC)
71215SN33N00N0C111P3
Quote Required
TBD
NPTStainless Steel 430 FFluid Control DivisionLiquids and GasesNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way110/50-120/60NBRDirect Acting7/16 inchn/a7000 Series210 W (AC)2 Cvn/aNEMA 4X185 °F0 °F6 psi (AC)3/8 inch0 psi430F Stainless1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X110/50-120/6010 Watt (AC)NBR27/166 psi (AC)
71215SN33N00N0C111Q3
Quote Required
TBD
NPTStainless Steel 430 FFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way220/50 to 240/60NBRDirect Acting7/16 inchn/a7000 Series210 W (AC)2 Cvn/aNEMA 4X185 °F0 °F6 psi (AC)3/8 inch0 psi430F Stainless1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X220/50-240/6010 Watt (AC)NBR27/166 psi (AC)
71215SN33N00N0C322C2
Quote Required
TBD
NPTStainless Steel 430 FFluid Control DivisionLiquids and GasesNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way24.0 VDCNBRDirect Acting7/16 inchn/a7000 Series222 W (DC)2 Cvn/aNEMA 4X185 °F0 °F5 psi (DC)3/8 inch0 psi430F Stainless1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X24 VDC22 Watt (DC)NBR27/165 psi (DC)
71215SN33N00N0C322P3
Quote Required
TBD
NPTStainless Steel 430 FFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way110/50-120/60NBRDirect Acting7/16 inchn/a7000 Series222 W (AC)2 Cvn/aNEMA 4X185 °F0 °F25 psi (AC)3/8 inch0 psi430F Stainless1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X110/50-120/6022 Watt (AC)NBR27/1625 psi (AC)
71215SN33NHPN0C111P3
Quote Required
$179.27
EANPTStainless Steel 430 FFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way110/50-120/60NBRDirect Acting7/16 inchn/a7000 Series210 W (AC)2 Cvn/aNEMA 4X185 °F0 °F11 psi (AC)3/8 inch5 psi430F Stainless1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X110/50-120/6010 Watt (AC)NBR27/1611 psi (AC)
71215SN33NHPN0H111P3
Quote Required
TBD
NPTStainless Steel 430 FFluid Control DivisionLiquids and GasesNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 92-Way110/50-120/60NBRDirect Acting7/16 inchn/a7000 Series210 W (AC)2 Cvn/aNEMA 9185 °F0 °F11 psi (AC)3/8 inch5 psi430F Stainless1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9110/50-120/6010 Watt (AC)NBR27/1611 psi (AC)
7121KBN3UV00N0C111C1
Quote Required
TBD
NPTBrassFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way12.0FKMDirect Acting7/16n/a7000 Series210 W (DC)0.83n/aNEMA 4X185020 psi (DC)3/80BRASS1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X12 VDC10 Watt (DC)FKM0.837/1620 psi (DC)
7121KBN3UV00N0C111C2
Quote Required
TBD
NPTBrassFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way24.0FKMDirect Acting7/16n/a7000 Series210 W (DC)0.83n/aNEMA 4X185020 psi (DC)3/80BRASS1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X24 VDC10 Watt (DC)FKM0.837/1620 psi (DC)
7121KBN3UV00N0C111P3
Quote Required
TBD
NPTBrassFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way110/50-120/60FKMDirect Acting7/16 inchn/a7000 Series210 W (AC)0.83 Cvn/aNEMA 4X185 °F0 °F55 psi (AC)3/8 inch0 psiBRASS1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X110/50-120/6010 Watt (AC)FKM0.837/1655 psi (AC)
7121KBN3UV00N0C111Q3
Quote Required
TBD
NPTBrassFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X2-Way220/50 to 240/60FKMDirect Acting7/16n/a7000 Series210 W (AC)0.83n/aNEMA 4X185055 psi (AC)3/80BRASS1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X220/50-240/6010 Watt (AC)FKM0.837/1655 psi (AC)
7121KBN3UV00N0C222C1
Quote Required
TBD
NPTBrassFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way12.0 VDCFKMDirect Acting7/16 inchn/a7000 Series210 W (DC)0.83 Cvn/aNEMA 4X185 °F0 °F20 psi (DC)3/8 inch0 psiBRASS1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X12 VDC10 Watt (DC)FKM0.837/1620 psi (DC)
7121KBN3UV00N0C222C2
Quote Required
TBD
NPTBrassFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way24.0FKMDirect Acting7/16n/a7000 Series210 W (DC)0.83n/aNEMA 4X185020 psi (DC)3/80BRASS1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X24 VDC10 Watt (DC)FKM0.837/1620 psi (DC)
7121KBN3UV00N0C222P3
Quote Required
TBD
NPTBrassFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way110/50-120/60FKMDirect Acting7/16n/a7000 Series210 W (AC)0.83n/aNEMA 4X185055 psi (AC)3/80BRASS1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X110/50-120/6010 Watt (AC)FKM0.837/1655 psi (AC)
7121KBN3UV00N0C222Q3
Quote Required
TBD
NPTBrassFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way220/50 to 240/60FKMDirect Acting7/16n/a7000 Series210 W (AC)0.83n/aNEMA 4X185055 psi (AC)3/80BRASS1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X220/50-240/6010 Watt (AC)FKM0.837/1655 psi (AC)
7121KBN3UV00N0C322C1
Quote Required
TBD
NPTBrassFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way12.0FKMDirect Acting7/16n/a7000 Series222 W (DC)0.83n/aNEMA 4X185030 psi (DC)3/80BRASS1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X12 VDC22 Watt (DC)FKM0.837/1630 psi (DC)
7121KBN3UV00N0C322C2
Quote Required
TBD
NPTBrassFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X2-Way24.0FKMDirect Acting7/16n/a7000 Series222 W (DC)0.83n/aNEMA 4X185030 psi (DC)3/80BRASS1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X24 VDC22 Watt (DC)FKM0.837/1630 psi (DC)
7121KBN3UV00N0D100C2
Quote Required
$161.78
EANPTBrassFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)DIN Form A, Class F2-Way24.0 VDCFKMDirect Acting7/16 inchn/a7000 Series210 W (DC)0.83 Cvn/aClass F185 °F0 °F20 psi (DC)3/8 inch0 psiBRASSDIN Form A, Class F24 VDC10 Watt (DC)FKM0.837/1620 psi (DC)
7121KBN3UV00N0D100P3
Quote Required
TBD
NPTBrassFluid Control DivisionLiquids and GasesNormally Closed (NC)DIN Form A, Class F2-Way110/50-120/60FKMDirect Acting7/16 inchn/a7000 Series210 W (AC)0.83 Cvn/aClass F185 °F0 °F55 psi (AC)3/8 inch0 psiBRASSDIN Form A, Class F110/50-120/6010 Watt (AC)FKM0.837/1655 psi (AC)
7121KBN3UV00N0H111C1
Quote Required
TBD
NPTBrassFluid Control DivisionGeneral Purpose for AirNormally Closed (NC)1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 92-Way12.0FKMDirect Acting7/16n/a7000 Series210 W (DC)0.83n/aNEMA 9185020 psi (DC)3/80BRASS1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 912 VDC10 Watt (DC)FKM0.837/1620 psi (DC)