- Availability & Price
- Search SKU
- Coil Type
- Flow Factor 1 (Cv)
- Maximum Pressure Differential (psi)
- Orifice 1 Size (inch)
- Power (Watts)
- Voltage (V)
Parker 2-Way Normally Closed, 1-1/2" NPT General Purpose Solenoid Valves
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker's 2-Way Normally Closed 1-1/2" NPT Solenoid Valves are used in a wide variety of applications ideally suited for general purpose air, liquids and gases. These valves are available in brass construction. Coil options are available in 1/2" NPT Conduit and DIN Form A in Class F and H or NEMA 4X, 7 or 9 specification.
Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation
Features/ Benefits:
• High Quality Standards of Skinner® and Gold Ring™ Brand
• Modular Design
• Long Life
• Tight Shutoff
Applications:
• Instrumentation Equipment
• Analyzers and Diagnostic Equipment
• Medical and Dental Equipment
• Portable Welding Equipment
• Spraying Equipment
• Lubrication Equipment
• Beverage Dispensing & Vending machines
• Oil Burners
• Humidification and Misting Equipment
• Mobile Fuel Shut Off
• Textile and Dry Cleaning Equipment
• Commercial Dishwashers
• Commercial Laundry and Dryers
• Air Horns
• Pneumatic Fan Clutch
• Irrigation Equipment
| Action | Part No. | Availability | Partner Available | Price | UOM | Port Type | Body Material | Division | Port Size | Media | Function | Coil Type | Valve Type | Input Voltage | Seal Material | Orifice 2 Size | Product Series | Number of Ports | Flow Coefficient 2 | Coil Specifications Met | Maximum Fluid Temperature | Minimum Fluid Temperature | Minimum Pressure Differential | Power Consumption | Maximum Pressure Differential | Actuation Type | Orifice 1 Size | Flow Coefficient 1 | Coil Type | Voltage (V) | Power (Watts) | Maximum Pressure Differential (psi) | Flow Factor 1 (Cv) | Orifice 1 Size (inch) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 24F24C2180A3FPH75 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | DIN Form A, Class F | 2-Way | 12.0 | NBR | n/a | Gold Ring Series | 2 | n/a | Class F | 180 | 0 | 5 | 11.5 | 125 | Offset Diaphragm | 1-1/4 | 22.5 | DIN Form A, Class F | 12 VDC | 11.5 Watt (DC) | 125 psi (DC) | 22.5 | 1-1/4 | |||
| 24F24C2180AAFPH01 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | DIN Form A, Class F | 2-Way | 24/60 | NBR | n/a | Gold Ring Series | 2 | n/a | Class F | 180 | 0 | 5 | 6 | 150 | Offset Diaphragm | 1-1/4 | 22.5 | DIN Form A, Class F | 24/60 | 6 Watt (AC) | 150 psi (AC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0C111C1 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X | 2-Way | 12.0 | NBR | n/a | 7000 Series | 2 | n/a | NEMA 4X | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X | 12 VDC | 10 Watt (DC) | 125 psi (DC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0C111C2 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 inch | General Purpose for Air | Normally Closed (NC) | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X | 2-Way | 24.0 VDC | NBR | n/a | 7000 Series | 2 | n/a | NEMA 4X | 185 °F | 0 °F | 5 psi | 10 W | 125 psi | Manual | 1-1/4 inch | 22.5 Cv | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X | 24 VDC | 10 Watt (DC) | 125 psi (DC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0C111P3 | Quote Required | $797.72 | EA | NPT | Brass | Fluid Control Division | 1-1/2 inch | General Purpose for Air | Normally Closed (NC) | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X | 2-Way | 110/50-120/60 | NBR | n/a | 7000 Series | 2 | n/a | NEMA 4X | 185 °F | 0 °F | 5 psi | 10 W | 125 psi | Manual | 1-1/4 inch | 22.5 Cv | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X | 110/50-120/60 | 10 Watt (AC) | 125 psi (AC) | 22.5 | 1-1/4 | ||
| 73218BN87N00N0C111Q3 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X | 2-Way | 220/50 to 240/60 | NBR | n/a | 7000 Series | 2 | n/a | NEMA 4X | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 4X | 220/50-240/60 | 10 Watt (AC) | 125 psi (AC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0C222C1 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X | 2-Way | 12.0 | NBR | n/a | 7000 Series | 2 | n/a | NEMA 4X | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X | 12 VDC | 10 Watt (DC) | 125 psi (DC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0C222C2 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X | 2-Way | 24.0 | NBR | n/a | 7000 Series | 2 | n/a | NEMA 4X | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X | 24 VDC | 10 Watt (DC) | 125 psi (DC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0C222P3 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X | 2-Way | 110/50-120/60 | NBR | n/a | 7000 Series | 2 | n/a | NEMA 4X | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X | 110/50-120/60 | 10 Watt (AC) | 125 psi (AC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0C222Q3 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X | 2-Way | 220/50 to 240/60 | NBR | n/a | 7000 Series | 2 | n/a | NEMA 4X | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | 1/2" NPT Conduit, 18" Leads, Class H, NEMA 4X | 220/50-240/60 | 10 Watt (AC) | 125 psi (AC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0D100C1 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | DIN Form A, Class F | 2-Way | 12.0 | NBR | n/a | 7000 Series | 2 | n/a | Class F | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | DIN Form A, Class F | 12 VDC | 10 Watt (DC) | 125 psi (DC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0D100C2 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | DIN Form A, Class F | 2-Way | 24.0 | NBR | n/a | 7000 Series | 2 | n/a | Class F | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | DIN Form A, Class F | 24 VDC | 10 Watt (DC) | 125 psi (DC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0D100P3 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 inch | General Purpose for Air | Normally Closed (NC) | DIN Form A, Class F | 2-Way | 110/50-120/60 | NBR | n/a | 7000 Series | 2 | n/a | Class F | 185 °F | 0 °F | 5 psi | 10 W | 125 psi | Manual | 1-1/4 inch | 22.5 Cv | DIN Form A, Class F | 110/50-120/60 | 10 Watt (AC) | 125 psi (AC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0D100Q3 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | DIN Form A, Class F | 2-Way | 220/50 to 240/60 | NBR | n/a | 7000 Series | 2 | n/a | Class F | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | DIN Form A, Class F | 220/50-240/60 | 10 Watt (AC) | 125 psi (AC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0D200C1 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | DIN Form A, Class H | 2-Way | 12.0 | NBR | n/a | 7000 Series | 2 | n/a | Class H | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | DIN Form A, Class H | 12 VDC | 10 Watt (DC) | 125 psi (DC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0D200P3 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | DIN Form A, Class H | 2-Way | 110/50-120/60 | NBR | n/a | 7000 Series | 2 | n/a | Class H | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | DIN Form A, Class H | 110/50-120/60 | 10 Watt (AC) | 125 psi (AC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0H111C1 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 | 2-Way | 12.0 | NBR | n/a | 7000 Series | 2 | n/a | NEMA 9 | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 | 12 VDC | 10 Watt (DC) | 125 psi (DC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0H111C2 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 | 2-Way | 24.0 | NBR | n/a | 7000 Series | 2 | n/a | NEMA 9 | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 | 24 VDC | 10 Watt (DC) | 125 psi (DC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0H111P3 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 inch | Liquids and Gases | Normally Closed (NC) | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 | 2-Way | 110/50-120/60 | NBR | n/a | 7000 Series | 2 | n/a | NEMA 9 | 185 °F | 0 °F | 5 psi | 10 W | 125 psi | Manual | 1-1/4 inch | 22.5 Cv | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 | 110/50-120/60 | 10 Watt (AC) | 125 psi (AC) | 22.5 | 1-1/4 | |||
| 73218BN87N00N0H111Q3 | Quote Required | TBD | NPT | Brass | Fluid Control Division | 1-1/2 | General Purpose for Air | Normally Closed (NC) | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 | 2-Way | 220/50 to 240/60 | NBR | n/a | 7000 Series | 2 | n/a | NEMA 9 | 185 | 0 | 5 | 10 | 125 | Manual | 1-1/4 | 22.5 | 1/2" NPT Conduit, 18" Leads, Class F, NEMA 7, 9 | 220/50-240/60 | 10 Watt (AC) | 125 psi (AC) | 22.5 | 1-1/4 |