OIL-X IP50 Intermediate Pressure Compressed Air Filter (For Pressures Up To 50 bar g)
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The removal of impurities within a compressed air system is vitally important in order to prevent contamination of downstream processes equipment and products. Parker domnick hunter OIL-X IP50 intermediate pressure filters combine the new energy efficient OIL-Xplus filter elements with specially designed housings to provide high efficiency filtration for applications up to 50 bar g (725 psi g).
Available in various filtration grades and connection sizes, they provide a level of protection tailored to your application. Typical Applications: P.E.T. bottling, air blast circuit breakers, shipborne air distribution systems, engine starting and pressure testing of pipelines.
Features
• Coalescing filters fully tested in accordance with ISO12500-1.
• Performance independently validated by Lloyds Register.
• Elimination of oil, water and dirt - Available in six filtration grades.
• 10 years guarantee on filter housing.
• Ease of installation - Compact housing design.
• Port options - BSPP / NPT - Weld Flange kits also available.
Benefits
• Meets or exceeds the requirements for delivered air quality shown in all editions of ISO8573-1, the international standard for compressed air quality.
• Ideally suited for Food / Beverage / Pharmaceutical / P.E.T. applications: FDA Title 21 compliance and EC1935 - 2004 Exempt.
• Trouble free, high performance - quality OIL-Xplus element backed with a 1 year performance guarantee.
Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.
Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Available in various filtration grades and connection sizes, they provide a level of protection tailored to your application. Typical Applications: P.E.T. bottling, air blast circuit breakers, shipborne air distribution systems, engine starting and pressure testing of pipelines.
Features
• Coalescing filters fully tested in accordance with ISO12500-1.
• Performance independently validated by Lloyds Register.
• Elimination of oil, water and dirt - Available in six filtration grades.
• 10 years guarantee on filter housing.
• Ease of installation - Compact housing design.
• Port options - BSPP / NPT - Weld Flange kits also available.
Benefits
• Meets or exceeds the requirements for delivered air quality shown in all editions of ISO8573-1, the international standard for compressed air quality.
• Ideally suited for Food / Beverage / Pharmaceutical / P.E.T. applications: FDA Title 21 compliance and EC1935 - 2004 Exempt.
• Trouble free, high performance - quality OIL-Xplus element backed with a 1 year performance guarantee.
Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.
Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Division | Weight | Maximum Operating Pressure | Maximum Operating Temperature | Maximum Flow Rate | Depth | Width | Height | Compatible Element | Pressure Differential | Minimum Operating Temperature | Micron Rating | Connection Type | Filter Type | Port Connection (inch) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AARIP50-040-DGMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 2 | 50 | 100 | 522 m3/hour at 50 barg | 84 | 89 | 245 | K030ARR | 100 mbar (Dry) | 2 | Down to 0.01 micron | BSPP | Dry Particulate | ¾ | ||
| AARIP50-040-DNMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 2 | 50 | 100 | 522 m3/hour at 50 barg | 84 | 89 | 245 | K030ARR | 100 mbar (Dry) | 2 | Down to 0.01 micron | NPT | Dry Particulate | ¾ | ||
| AARIP50-050-EGMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 5 | 50 | 100 | 1026 m3/hour at 50 barg | 116 | 122 | 423 | K145ARR | 100 mbar (Dry) | 2 | Down to 0.01 micron | BSPP | Dry Particulate | 1 | ||
| AARIP50-050-ENMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 5 | 50 | 100 | 1026 m3/hour at 50 barg | 116 | 122 | 423 | K145ARR | 100 mbar (Dry) | 2 | Down to 0.01 micron | NPT | Dry Particulate | 1 | ||
| AARIP50-060-GGMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 5 | 50 | 100 | 1674 m3/hour at 50 barg | 116 | 122 | 423 | K145ARR | 100 mbar (Dry) | 2 | Down to 0.01 micron | BSPP | Dry Particulate | 1½ | ||
| AARIP50-060-GNMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 5 | 50 | 100 | 1674 m3/hour at 50 barg | 116 | 122 | 423 | K145ARR | 100 mbar (Dry) | 2 | Down to 0.01 micron | NPT | Dry Particulate | 1½ | ||
| AARIP50-070-HGMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 22 lb | 50 barg | 212 °F | 3473 m3/hour at 50 barg | 162 mm | 170 mm | 480 mm | K220ARR | 1.5 psi (Dry) | 2 °C | Down to 0.01 micron | BSPP | Dry Particulate | 2 | ||
| AARIP50-070-HNMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 10 | 50 | 100 | 3473 m3/hour at 50 barg | 162 | 170 | 480 | K220ARR | 100 mbar (Dry) | 2 | Down to 0.01 micron | NPT | Dry Particulate | 2 | ||
| ACSIP50-010-AGMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 10 kg | 725 psig | 86 °F | 64 CFM at 725 psig | 6.4 inch | 6.7 inch | 18.9 inch | K009ACS | 100 mbar (Dry) | 35 °F | n/a | BSPP | Oil Vapour Removal | ¼ | ||
| ACSIP50-010-ANMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 10 | 50 | 30 | 108 m3/hour at 50 barg | 162 | 170 | 480 | K009ACS | 100 mbar (Dry) | 2 | n/a | NPT | Oil Vapour Removal | ¼ | ||
| ACSIP50-020-BGMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 10 kg | 50 barg | 30 °C | 95 CFM at 725 psig | 162 mm | 170 mm | 18.9 inch | K009ACS | 1.5 psi (Dry) | 2 °C | n/a | BSPP | Oil Vapour Removal | 3/8 | ||
| ACSIP50-020-BNMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 10 | 50 | 30 | 162 m3/hour at 50 barg | 162 | 170 | 480 | K009ACS | 100 mbar (Dry) | 2 | n/a | NPT | Oil Vapour Removal | 3/8 | ||
| ACSIP50-030-CGMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 22 lb | 50 barg | 30 °C | 201 CFM at 725 psig | 162 mm | 170 mm | 18.9 inch | K030ACS | 1.5 psi (Dry) | 2 °C | n/a | BSPP | Oil Vapour Removal | ½ | ||
| ACSIP50-030-CNMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 10 | 50 | 30 | 342 m3/hour at 50 barg | 162 | 170 | 480 | K030ACS | 100 mbar (Dry) | 2 | n/a | NPT | Oil Vapour Removal | ½ | ||
| ACSIP50-040-DGMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 10 kg | 725 psig | 86 °F | 522 m3/hour at 50 barg | 6.4 inch | 170 mm | 18.9 inch | K030ACS | 1.5 psi (Dry) | 2 °C | n/a | BSPP | Oil Vapour Removal | ¾ | ||
| ACSIP50-040-DNMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 10 | 50 | 30 | 522 m3/hour at 50 barg | 162 | 170 | 480 | K030ACS | 100 mbar (Dry) | 2 | n/a | NPT | Oil Vapour Removal | ¾ | ||
| ACSIP50-050-EGMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 10 kg | 725 psig | 86 °F | 1026 m3/hour at 50 barg | 162 mm | 6.7 inch | 18.9 inch | K145ACS | 1.5 psi (Dry) | 35 °F | n/a | BSPP | Oil Vapour Removal | 1 | ||
| ACSIP50-050-ENMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 10 kg | 725 psig | 30 °C | 604 CFM at 725 psig | 6.4 inch | 6.7 inch | 480 mm | K145ACS | 1.5 psi (Dry) | 35 °F | n/a | NPT | Oil Vapour Removal | 1 | ||
| ACSIP50-060-GGMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 10 kg | 725 psig | 30 °C | 985 CFM at 725 psig | 162 mm | 6.7 inch | 480 mm | K145ACS | 100 mbar (Dry) | 2 °C | n/a | BSPP | Oil Vapour Removal | 1½ | ||
| ACSIP50-060-GNMX | Quote Required | TBD | Gas Separation and Filtration Division EMEA | 10 | 50 | 30 | 1674 m3/hour at 50 barg | 162 | 170 | 480 | K145ACS | 100 mbar (Dry) | 2 | n/a | NPT | Oil Vapour Removal | 1½ |