OIL-X IP50 Intermediate Pressure Compressed Air Filter (For Pressures Up To 50 bar g)

Picture for category OIL-X IP50 Intermediate Pressure Compressed Air Filter (For Pressures Up To 50 bar g)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The removal of impurities within a compressed air system is vitally important in order to prevent contamination of downstream processes equipment and products. Parker domnick hunter OIL-X IP50 intermediate pressure filters combine the new energy efficient OIL-Xplus filter elements with specially designed housings to provide high efficiency filtration for applications up to 50 bar g (725 psi g).

Available in various filtration grades and connection sizes, they provide a level of protection tailored to your application. Typical Applications: P.E.T. bottling, air blast circuit breakers, shipborne air distribution systems, engine starting and pressure testing of pipelines.

Features
• Coalescing filters fully tested in accordance with ISO12500-1.

• Performance independently validated by Lloyds Register.

• Elimination of oil, water and dirt - Available in six filtration grades.

• 10 years guarantee on filter housing.

• Ease of installation - Compact housing design.

• Port options - BSPP / NPT - Weld Flange kits also available.

Benefits
• Meets or exceeds the requirements for delivered air quality shown in all editions of ISO8573-1, the international standard for compressed air quality.

• Ideally suited for Food / Beverage / Pharmaceutical / P.E.T. applications: FDA Title 21 compliance and EC1935 - 2004 Exempt.

• Trouble free, high performance - quality OIL-Xplus element backed with a 1 year performance guarantee.

Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.

Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceDivisionWeightMaximum Operating PressureMaximum Operating TemperatureMaximum Flow RateDepthWidthHeightCompatible ElementPressure DifferentialMinimum Operating TemperatureMicron RatingConnection TypeFilter TypePort Connection (inch)
AARIP50-040-DGMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA250100522 m3/hour at 50 barg8489245K030ARR100 mbar (Dry)2Down to 0.01 micronBSPPDry Particulate¾
AARIP50-040-DNMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA250100522 m3/hour at 50 barg8489245K030ARR100 mbar (Dry)2Down to 0.01 micronNPTDry Particulate¾
AARIP50-050-EGMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA5501001026 m3/hour at 50 barg116122423K145ARR100 mbar (Dry)2Down to 0.01 micronBSPPDry Particulate1
AARIP50-050-ENMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA5501001026 m3/hour at 50 barg116122423K145ARR100 mbar (Dry)2Down to 0.01 micronNPTDry Particulate1
AARIP50-060-GGMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA5501001674 m3/hour at 50 barg116122423K145ARR100 mbar (Dry)2Down to 0.01 micronBSPPDry Particulate
AARIP50-060-GNMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA5501001674 m3/hour at 50 barg116122423K145ARR100 mbar (Dry)2Down to 0.01 micronNPTDry Particulate
AARIP50-070-HGMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA22 lb50 barg212 °F3473 m3/hour at 50 barg162 mm170 mm480 mmK220ARR1.5 psi (Dry)2 °CDown to 0.01 micronBSPPDry Particulate2
AARIP50-070-HNMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA10501003473 m3/hour at 50 barg162170480K220ARR100 mbar (Dry)2Down to 0.01 micronNPTDry Particulate2
ACSIP50-010-AGMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA10 kg725 psig86 °F64 CFM at 725 psig6.4 inch6.7 inch18.9 inchK009ACS100 mbar (Dry)35 °Fn/aBSPPOil Vapour Removal¼
ACSIP50-010-ANMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA105030108 m3/hour at 50 barg162170480K009ACS100 mbar (Dry)2n/aNPTOil Vapour Removal¼
ACSIP50-020-BGMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA10 kg50 barg30 °C95 CFM at 725 psig162 mm170 mm18.9 inchK009ACS1.5 psi (Dry)2 °Cn/aBSPPOil Vapour Removal3/8
ACSIP50-020-BNMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA105030162 m3/hour at 50 barg162170480K009ACS100 mbar (Dry)2n/aNPTOil Vapour Removal3/8
ACSIP50-030-CGMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA22 lb50 barg30 °C201 CFM at 725 psig162 mm170 mm18.9 inchK030ACS1.5 psi (Dry)2 °Cn/aBSPPOil Vapour Removal½
ACSIP50-030-CNMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA105030342 m3/hour at 50 barg162170480K030ACS100 mbar (Dry)2n/aNPTOil Vapour Removal½
ACSIP50-040-DGMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA10 kg725 psig86 °F522 m3/hour at 50 barg6.4 inch170 mm18.9 inchK030ACS1.5 psi (Dry)2 °Cn/aBSPPOil Vapour Removal¾
ACSIP50-040-DNMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA105030522 m3/hour at 50 barg162170480K030ACS100 mbar (Dry)2n/aNPTOil Vapour Removal¾
ACSIP50-050-EGMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA10 kg725 psig86 °F1026 m3/hour at 50 barg162 mm6.7 inch18.9 inchK145ACS1.5 psi (Dry)35 °Fn/aBSPPOil Vapour Removal1
ACSIP50-050-ENMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA10 kg725 psig30 °C604 CFM at 725 psig6.4 inch6.7 inch480 mmK145ACS1.5 psi (Dry)35 °Fn/aNPTOil Vapour Removal1
ACSIP50-060-GGMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA10 kg725 psig30 °C985 CFM at 725 psig162 mm6.7 inch480 mmK145ACS100 mbar (Dry)2 °Cn/aBSPPOil Vapour Removal
ACSIP50-060-GNMX
Quote Required
TBD
Gas Separation and Filtration Division EMEA1050301674 m3/hour at 50 barg162170480K145ACS100 mbar (Dry)2n/aNPTOil Vapour Removal