OIL-X Carbon Steel Fabricated Compressed Air Filter (For Pressures Up To 16 bar g)

Picture for category OIL-X Carbon Steel Fabricated Compressed Air Filter (For Pressures Up To 16 bar g)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker domnick hunter OIL-X range of fabricated carbon steel compressed air filters combine an innovative filter housing and filter element design to achieve optimum flow characteristics with minimum pressure drop, resulting in considerable cost savings throughout the entire operating lifetime of the filter element.

The filter housing has been designed for ease of maintenance. A low placed service flange, supported by a pivoting hinge joint, enables element replacement to be undertaken by a single individual. A dished housing bottom provides ample space to drain away liquids efficiently. The patented filter element design provides a secure seal to avoid any possibility of contamination bypassing the element.

Features
• Fabricated from carbon steel

• Standard range up to 16 barg (232 psig)

• Stainless steel models also available

• Designed in accordance with AD-2000

• Easy fit element location for quick and simple maintenance

• Coalescing filter performance tested to the stringent requirements of ISO12500-1 and ISO8573-2

• Dry particulate filter performance tested in accordance with the requirements of ISO8573-4

• Differential pressure gauge can be fitted as optional extra

Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.

Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandDivisionMaximum Operating TemperatureMinimum Operating TemperatureMaximum Operating PressureDepthConnection TypeWidthHeightWeightMaximum Flow RateMinimum Operating PressurePort ConnectionMicron RatingFilter TypeDrainOptionsMaximum Flow RateMaximum Flow Rate (cfm)
AA090RDEI
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA140 °F2 °C232 psig840 mmDIN Flange1000 mm1603 mm470 kg13129 CFM at 100 psig15 psigDN250 psigDown to 0.01 micronHigh Efficiency CoalescingElectronicIncident Monitor22320 m³/h @ 7 barg13129 cfm @ 100 psig
AA090RDEX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA60 °C2 °C16 barg33 inchDIN Flange1000 mm1603 mm470 kg13129 CFM at 100 psig15 psigDN250 psigDown to 0.01 micronHigh Efficiency CoalescingElectronicNone22320 m³/h @ 7 barg13129 cfm @ 100 psig
AA090RDMI
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA100 °C2 °C16 barg840 mmDIN Flange39.4 inch63.1 inch470 kg13129 CFM at 100 psig1 bargDN250 psigDown to 0.01 micronDry ParticulateManualIncident Monitor22320 m³/h @ 7 barg13129 cfm @ 100 psig
AA090RDMX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA212 °F2 °C16 barg33 inchDIN Flange39.4 inch1603 mm470 kg13129 CFM at 100 psig15 psigDN250 psigDown to 0.01 micronDry ParticulateManualNone22320 m³/h @ 7 barg13129 cfm @ 100 psig
AA095SDEI
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA60 °C35 °F232 psig910 mmDIN Flange1050 mm67.2 inch580.0 kg18380 CFM at 100 psig15 psigDN300 psigDown to 0.01 micronHigh Efficiency CoalescingElectronicIncident Monitor31248 m³/h @ 7 barg18380 cfm @ 100 psig
AA095SDEX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA60 °C2 °C232 psig910 mmDIN Flange1050 mm1706 mm1279 lb18380 CFM at 100 psig1 bargDN300 psigDown to 0.01 micronHigh Efficiency CoalescingElectronicNone31248 m³/h @ 7 barg18380 cfm @ 100 psig
AA095SDMI
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA212 °F2 °C16 barg910 mmDIN Flange41.3 inch1706 mm580.0 kg18380 CFM at 100 psig1 bargDN300 psigDown to 0.01 micronDry ParticulateManualIncident Monitor31248 m³/h @ 7 barg18380 cfm @ 100 psig
AA095SDMX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA100 °C35 °F16 barg910 mmDIN Flange1050 mm1706 mm580.0 kg18380 CFM at 100 psig1 bargDN300 psigDown to 0.01 micronDry ParticulateManualNone31248 m³/h @ 7 barg18380 cfm @ 100 psig
ACS065NDMX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA122 °F2 °C16 barg340 mmDIN Flange440 mm42.0 inch70 kg1312 CFM at 100 psig1 bargDN80 °Fn/aOil Vapour RemovalManualNone2232 m³/h @ 7 barg1312 cfm @ 100 psig
ACS070ODMX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA122 °F2 °C16 barg16 inchDIN Flange500 mm45.4 inch97 kg2625 CFM at 100 psig15 psigDN100 °Fn/aOil Vapour RemovalManualNone4464 m³/h @ 7 barg2625 cfm @ 100 psig
ACS075PDMX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA50 °C35 °F16 barg520 mmDIN Flange600 mm49.5 inch148.0 kg3938 CFM at 100 psig15 psigDN150 °Fn/aOil Vapour RemovalManualNone6696 m³/h @ 7 barg3938 cfm @ 100 psig
ACS080PDMX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA122 °F35 °F232 psig22.8 inchDIN Flange650 mm52.4 inch412 lb5251 CFM at 100 psig1 bargDN150 °Fn/aOil Vapour RemovalManualNone8928 m³/h @ 7 barg5251 cfm @ 100 psig
ACS085QDMX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA50 °C2 °C16 barg640 mmDIN Flange29.5 inch55.7 inch529 lb7877 CFM at 100 psig15 psigDN200 °Fn/aOil Vapour RemovalManualNone13392 m³/h @ 7 barg7877 cfm @ 100 psig
ACS090RDMX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA50 °C2 °C232 psig33 inchDIN Flange1000 mm1603 mm470 kg13129 CFM at 100 psig1 bargDN250 °Fn/aOil Vapour RemovalManualNone22320 m³/h @ 7 barg13129 cfm @ 100 psig
ACS095SDMX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA50 °C35 °F16 barg910 mmDIN Flange1050 mm1706 mm580.0 kg18380 CFM at 100 psig1 bargDN300 °Fn/aOil Vapour RemovalManualNone31248 m³/h @ 7 barg18380 cfm @ 100 psig
AO065NDEI
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA60 °C35 °F16 barg340 mmDIN Flange440 mm1065 mm154 lb1312 CFM at 100 psig1 bargDN80 bargDown 1 micronGeneral Purpose CoalescingElectronicIncident Monitor2232 m³/h @ 7 barg1312 cfm @ 100 psig
AO065NDEX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA60 °C35 °F16 barg340 mmDIN Flange17.3 inch42.0 inch154 lb1312 CFM at 100 psig15 psigDN80 bargDown 1 micronGeneral Purpose CoalescingElectronicNone2232 m³/h @ 7 barg1312 cfm @ 100 psig
AO065NDMI
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA212 °F35 °F16 barg340 mmDIN Flange440 mm42.0 inch154 lb1312 CFM at 100 psig1 bargDN80 bargDown 1 micronDry ParticulateManualIncident Monitor2232 m³/h @ 7 barg1312 cfm @ 100 psig
AO065NDMX
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA212 °F2 °C16 barg340 mmDIN Flange440 mm1065 mm70 kg1312 CFM at 100 psig15 psigDN80 bargDown 1 micronDry ParticulateManualNone2232 m³/h @ 7 barg1312 cfm @ 100 psig
AO070ODEI
Quote Required
TBD
ParkerGas Separation and Filtration Division EMEA140 °F35 °F232 psig405 mmDIN Flange500 mm45.4 inch97 kg2625 CFM at 100 psig1 bargDN100 bargDown 1 micronGeneral Purpose CoalescingElectronicIncident Monitor4464 m³/h @ 7 barg2625 cfm @ 100 psig