- Availability & Price
- Search SKU
Filter by attributes
- Number of Tubes
- Tube O.D. (inch)
- Tubing Material
Filter by manufacturer
OBSOLETE: SL - Self-Regulating Temptrace™ Bundles for Low Temperature Maintenance
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parflex SL-Self-Regulating Temptrace™ Bundles are designed to provide freeze protection and low temperature maintenance for gases, liquids or other viscous materials in chemical processing and refinery applications. The tubing is thermally insulated with a non-hygroscopic inorganic fiberglass material and protected with a flexible, black, flame-resistant PVC jacket for added protection. The thermal insulation allows for the transfer of fluids or gases up to 185°F (85°C) while maintaining an outer jacket surface temperature of 140°F (60°C), meeting NEC Personnel Protection Code 427.12. Standard SL designs come with an internal tinned copper braid on the heating cable for grounding purposes and a TPR jacket over the heating cable to provide additional protection against many inorganic chemical solutions. For order details, refer to our latest literature on the Product Support tab.
Markets:
• Chemical Processing and Refining
Features/Benefits:
• Product is highly customizable – multiple options are available for tubing materials, tubing sizes, wall thicknesses, heating cable voltage and heat output, cover material and color
• Constructed with a flexible, flame-resistant PVC jacket for added protection
• Standard designs come with an internal copper braid on the heating cable for grounding purposes and a TPR jacket over the heating cable to provide additional protection against many inorganic chemical solutions
Applications:
• Designed to provide freeze protection and low temperature maintenance for gases, liquids or other viscous materials
Certifications/Compliance:
• NEC Personnel Protection Code 427.12
• Heating cables are rated per NEC standards:
- Cables with heat outputs of 3, 5 and 8 watts/ft have a T3 rating
- Cables with heat outputs of 10, 15 and 20 watts/ft have a T2D rating
Technical Specifications:
• Standard Tubing Materials: Seamless Copper Type 122 DHP ASTM B68-B75, as well as seamless and welded stainless steel tubing, Type 316/316L ASTM A269
• Insulation: Non-hygroscopic inorganic fiberglass
• Cover: FR-PVC
• Additional jacketing materials are available upon request, including non-halogenated FR-TPE and Urethanes
• Heating cables are available in 120V and 208-277 volt, with heat outputs of 3, 5, 8 and 10 watt/ft
• Readily available in 1/4”, 3/8”, and 1/2” sizes as well as metric sizes (6mm, 8mm, 10mm and 12mm)
• All Temptrace™ products are pressure tested prior to shipment
• Third party testing and witnessing is available upon request, including DNV, ABS and Lloyd's Register
Read More...Markets:
• Chemical Processing and Refining
Features/Benefits:
• Product is highly customizable – multiple options are available for tubing materials, tubing sizes, wall thicknesses, heating cable voltage and heat output, cover material and color
• Constructed with a flexible, flame-resistant PVC jacket for added protection
• Standard designs come with an internal copper braid on the heating cable for grounding purposes and a TPR jacket over the heating cable to provide additional protection against many inorganic chemical solutions
Applications:
• Designed to provide freeze protection and low temperature maintenance for gases, liquids or other viscous materials
Certifications/Compliance:
• NEC Personnel Protection Code 427.12
• Heating cables are rated per NEC standards:
- Cables with heat outputs of 3, 5 and 8 watts/ft have a T3 rating
- Cables with heat outputs of 10, 15 and 20 watts/ft have a T2D rating
Technical Specifications:
• Standard Tubing Materials: Seamless Copper Type 122 DHP ASTM B68-B75, as well as seamless and welded stainless steel tubing, Type 316/316L ASTM A269
• Insulation: Non-hygroscopic inorganic fiberglass
• Cover: FR-PVC
• Additional jacketing materials are available upon request, including non-halogenated FR-TPE and Urethanes
• Heating cables are available in 120V and 208-277 volt, with heat outputs of 3, 5, 8 and 10 watt/ft
• Readily available in 1/4”, 3/8”, and 1/2” sizes as well as metric sizes (6mm, 8mm, 10mm and 12mm)
• All Temptrace™ products are pressure tested prior to shipment
• Third party testing and witnessing is available upon request, including DNV, ABS and Lloyd's Register
| Action | Part No. | Availability | Partner Available | Price | Tube Outside Diameter | Minimum Bend Radius | Tube Material | Circuit Breaker Contact Rating | Input Voltage | Cover Color | Nominal Outside Diameter | Number of Tubes | Division | Heat Output | Maximum Internal Temperature | Circuit Length | Cover Material | Tubing Material | Number of Tubes | Tube O.D. (inch) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| SL812-21249B | Quote Required | TBD | 3/4 | n/a | Welded Stainless Steel Type 316/316L ASTM A269 | n/a | 120 | Black | n/a | 2 | Parflex Division | 5 | 185 | n/a | FR-PVC | Welded Stainless Steel Type 316/316L ASTM A269 | 2 | 3/4 | ||
| SL812-B0835B | Quote Required | TBD | 1/2 | 10 | Seamless Stainless Steel Type 316/316L ASTM A269 | 25 | 120 | Black | 1.61 | 2 | Parflex Division | 5 | 185 | 270 | FR-PVC | Seamless Stainless Steel Type 316/316L ASTM A269 | 2 | 1/2 | ||
| SL812-B1249A | Quote Required | TBD | 3/4 | 10 | Seamless Stainless Steel Type 316/316L ASTM A269 | 25 | 120 | Black | 1.64 | 1 | Parflex Division | 5 | 185 | 215 | FR-PVC | Seamless Stainless Steel Type 316/316L ASTM A269 | 1 | 3/4 | ||
| SL812-B1249B | Quote Required | TBD | 3/4 | 12 | Seamless Stainless Steel Type 316/316L ASTM A269 | 25 | 120 | Black | 1.99 | 2 | Parflex Division | 5 | 185 | 215 | FR-PVC | Seamless Stainless Steel Type 316/316L ASTM A269 | 2 | 3/4 |