OBSOLETE: CL-Constant Wattage Temptrace™ for Low Temperature Maintenance

Picture for category OBSOLETE: CL-Constant Wattage Temptrace™ for Low Temperature Maintenance

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

This product is no longer available from Parker. Contact us to find an alternative solution for your application.

Parflex CL Constant Wattage Temptrace™ electric trace tubing is capable of maintaining temperatures up to 250°F (121°C) and withstanding a maximum internal exposure up to 400°F (204°C) to effectively provide freeze protection, viscosity maintenance and low process temperature maintenance in applications that involve analyzer, impulse, and instrument lines, small diameter process lines, stack gas sampling lines and utility lines. The electric trace tubing consists of a process tube traced with a constant wattage heating cable, a heat transfer aluminum foil wrap for even heat distribution for precise temperature control, a non-hygroscopic glass fiber insulation for minimum heat loss, and a black, 105°C-rated, flame-resistant PVC (FR-PVC) jacket. This protective jacket safeguards the tubing against corrosive atmospheres, water, oils, acids, alkalies and most chemicals. For more information regarding tolerable temperature ranges and order details for CL Constant Wattage Temptrace™ tubing, refer to our latest literature on the Product Support tab.

Markets:  
• Process Control & Analyzer Systems

Features/Benefits:
• Designed to withstand a variety of temperature ranges
• Aluminum heat transfer foil allows for even heat distribution for precise temperature control
• Air-spaced, cross wrapped applied non-hygroscopic fiberglass thermal insulation provides minimum heat loss
• Standard black, flame-resistant PVC (FR-PVC) jacket protects the tubing against corrosive atmospheres, water, oils, acids, alkalies and most chemicals
• Product series is highly customizable - multiple options are available for tubing materials, tubing sizes, wall thicknesses, heating cable voltage and heat output, cover material and color

Applications:
• Provides freeze protection and viscosity maintenance
• Analyzer, impulse and instrument lines
• Small diameter process lines
• Stack gas sampling lines
• Utility lines

Technical Specifications:
• Standard Tubing Materials: Type 122 DHP Seamless Copper, 316/316L Welded and Seamless Stainless Steel, PFA, FEP and PTFE
• Insulation: Non-hygroscopic fiberglass
• Cover: FR-PVC
• Additional jacket materials and wall thicknesses are available upon request
• Each tube in every length of Parflex Temptrace™ is pressure tested prior to shipment to assure the instrument engineer a high-quality, reliable, trouble-free product
• Standard product has a Maximum Temperature Rating (MTR) of 400°F (204.4°C) when power to the heating cable is off, and 250°F (121.1°C) when power to the heating cable is on
        o Maximum Temperature Rating is the maximum allowable temperature of the tracing fluid; temperatures in excess of this may damage the product or alter its performance
• Accessories are available for electrical connections, bundle splicing and end terminations

NOTE: It is absolutely necessary to seal the ends against contamination from moisture and/or corrosive liquids. Parker Hannifin cannot assume any liability for product damage caused by moisture from unsealed ends.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceTube Outside DiameterNumber of TubesCover ColorSpecifications MetDivisionHeat OutputTube MaterialHeating Cable VoltageCover MaterialMaximum Operating TemperatureNumber of TubesTube Size (inch)Tubing Material
CL-412-F0635A
Quote Required
TBD
3/81BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Fluorinated Ethylene Propylene (FEP)120FR-PVC40013/8FEP Flouropolymer
CL-412-F0635B
Quote Required
TBD
3/82BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Fluorinated Ethylene Propylene (FEP)120FR-PVC40023/8FEP Flouropolymer
CL-412-F0835A
Quote Required
TBD
1/21BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Fluorinated Ethylene Propylene (FEP)120FR-PVC40011/2FEP Flouropolymer
CL-412-F0835B
Quote Required
TBD
1/22BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Fluorinated Ethylene Propylene (FEP)120FR-PVC40021/2FEP Flouropolymer
CL-412-P0435A
Quote Required
TBD
1/41BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Perfluoroalkoxy Alkanes (PFA)120FR-PVC40011/4PFA Flouropolymer
CL-412-P0435B
Quote Required
TBD
1/42BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Perfluoroalkoxy Alkanes (PFA)120FR-PVC40021/4PFA Flouropolymer
CL-412-P0635A
Quote Required
TBD
3/81BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Perfluoroalkoxy Alkanes (PFA)120FR-PVC40013/8PFA Flouropolymer
CL-412-P0635B
Quote Required
TBD
3/82BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Perfluoroalkoxy Alkanes (PFA)120FR-PVC40023/8PFA Flouropolymer
CL-412-P0835A
Quote Required
TBD
1/21BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Perfluoroalkoxy Alkanes (PFA)120FR-PVC40011/2PFA Flouropolymer
CL-412-P0835B
Quote Required
TBD
1/22BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Perfluoroalkoxy Alkanes (PFA)120FR-PVC40021/2PFA Flouropolymer
CL-412-T0435A
Quote Required
TBD
1/41BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Polytetrafluoroethylene (PTFE)120FR-PVC40011/4TFE Flouropolymer
CL-412-T0435B
Quote Required
TBD
1/42BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Polytetrafluoroethylene (PTFE)120FR-PVC40021/4TFE Flouropolymer
CL-412-T0635A
Quote Required
TBD
3/81BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Polytetrafluoroethylene (PTFE)120FR-PVC40013/8TFE Flouropolymer
CL-412-T0635B
Quote Required
TBD
3/82BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Polytetrafluoroethylene (PTFE)120FR-PVC40023/8TFE Flouropolymer
CL-412-T0835A
Quote Required
TBD
1/21BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Polytetrafluoroethylene (PTFE)120FR-PVC40011/2TFE Flouropolymer
CL-412-T0835B
Quote Required
TBD
1/22BlackGeneral Purpose & FM Class I, Division 2 AreasParflex Division4Polytetrafluoroethylene (PTFE)120FR-PVC40021/2TFE Flouropolymer