- Availability & Price
- Search SKU
Filter by attributes
- Maximum Tube O.D (inch)
Filter by manufacturer
OBSOLETE: Burial Ready Seal-Line™ Protected Stainless Steel Tubing for CNG Fueling Stations
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker's Seal-Line™ Tubing is delivered to your next project site burial ready. Seal-Line Tubing is designed to be used as a natural gas line for dispensing stations. It consists of a durable, thermoplastic cover extruded over the entire length of grade 316/316L seamless stainless steel tube to eliminate the damage that occurs from pulling unprotected tubing into place and across rough surfaces. Once delivered, the product is pulled directly from the supply reel and laid into the trench for burial applications. At the ends, where the tube needs to be connected to a fitting, the jacket material can be skived back to allow for a standard fitting connection. It also eliminates the need for welding, reducing the number of potential leak points and prevents surface scratch damage to the stainless steel tube. To achieve the most robust and leak-free connections, use with Parker's Seal-Lok™ fittings.
Markets:
• Oil & Gas - CNG Refueling Stations
Features/Benefits:
• Direct burial ready
• Installs 25% to 30% faster than bare coiled tubing
• 100% factory pressure tested
• Seamless tubing, with no mechanical joints
• Long, continuous lengths eliminate welded connections and potential leak points
• Thermoplastic jacket protects against dirt, chemical (chlorides) attack, surface scratches, stress corrosion, pitting corrosion and crevice corrosion for maximum life expectancy
Applications:
• CNG Dispensers
Technical Specifications:
• Operating temperature range of -40°F to 212°F (-40°C to 100°C)
• 316/316L stainless steel tube construction certified to ASTM A269 / A213 EAW, Seamless
• Meets National Association of Corrosion Engineers (NACE) MR0175
• Packaged lengths from 186 to 730 feet (56 to 222 meters)
Read More...Markets:
• Oil & Gas - CNG Refueling Stations
Features/Benefits:
• Direct burial ready
• Installs 25% to 30% faster than bare coiled tubing
• 100% factory pressure tested
• Seamless tubing, with no mechanical joints
• Long, continuous lengths eliminate welded connections and potential leak points
• Thermoplastic jacket protects against dirt, chemical (chlorides) attack, surface scratches, stress corrosion, pitting corrosion and crevice corrosion for maximum life expectancy
Applications:
• CNG Dispensers
Technical Specifications:
• Operating temperature range of -40°F to 212°F (-40°C to 100°C)
• 316/316L stainless steel tube construction certified to ASTM A269 / A213 EAW, Seamless
• Meets National Association of Corrosion Engineers (NACE) MR0175
• Packaged lengths from 186 to 730 feet (56 to 222 meters)
| Action | Part No. | Availability | Partner Available | Price | Compatible Fitting | Cover Color | Maximum Operating Temperature | Application | Minimum Bend Radius | Length per Package | Additional Options | Minimum Operating Temperature | Nominal Outside Diameter | Maximum Operating Pressure | Maximum Tube Outside Diameter | Division | Specifications Met | Maximum Tube O.D (inch) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CNGSL-12 | Quote Required | TBD | Seal-Lok™ | Yellow | 212 | CNG Fueling Stations | 6 | 324 ft +/-10% | The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. | -40 | 0.885 | 5500 | 3/4 | Parflex Division | ASTM A213 EAW | 3/4 | ||
| CNGSL-16 | Quote Required | TBD | Seal-Lok™ | Yellow | 212 | CNG Fueling Stations | 7 | 186 ft +/-10% | The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. | -40 | 1.135 | 5500 | 1 | Parflex Division | ASTM A213 EAW | 1 | ||
| CNGSL-8 | Quote Required | TBD | Seal-Lok™ | Yellow | 212 | CNG Fueling Stations | 4 | 730 ft +/-10% | The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. | -40 | 0.635 | 5500 | 1/2 | Parflex Division | ASTM A213 EAW | 1/2 |