By combining customer-specified valves into a single manifold valve, Parker’s monoflange significantly reduces the number of potential leak paths. The monoflanges also have a lower system mass, which reduces loading and vibration stresses, further improving safety and reliability. The Parker Monoflange has needle valve primary and secondary rather than ball valves. The monoflange is preferred by some operators as it is smaller than a traditonal double block and bleed valve, giving even more space and weight advantages. This ensures that the monoflange is it is a cost efficient option for owner / operators.

The monoflange allows the mounting options to suit whether the pipeline is vertical or horizontal, the gauge or pressure transmitter can be fitted on either the front face or on the outer diameter of the body to allow good orientation and ease of reading.  

Parker’s monoflange is available in a wide range of single-, two- and three-valve configurations, including block, double-block, block-and-bleed, double-block-and-bleed and block-bleed-block. Standard flange sizes include 1/2", 3/4", 1”, 1-1/2” and 2”, together with API and DIN standard versions, and there is a extensive choice of flange classes, from ANSI 150 to 2500. Standard outlet vents are 1/2" female NPT. Depending on monoflange size and configuration, other options include 1/4", 3/8”, 6 mm, 10 mm and 12 mm sizes, and male NPT or Parker inverted A-LOK™ double ferrule compression fittings.

Markets:
• Oil and Gas Offshore
• Oil and Gas Onshore
• Petrochemical
• Chemical

Features/Benefits:
• Close coupled
• One piece forged construction
• Shell TAT approval and meets MESC SPE 77/300
• Heat code traceable and NACE compliant materials
• ISO 15848 Class A (HS) and B standards
• Integral two and single ferrule connections, which reduces potential leak paths
• Reduced weight
• Reduced installation costs - can be fitted faster than traditional valves
• Fewer components
• Fire-safe versions that extend this to 538˚C (1000˚F)
• Corrosion resistant alloys

Applications:
• Process to instrument interface
• Gas or light liquid service
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceSeal MaterialFlange Face TypeConfigurationVent Plug Thread SizeHandle TypeMaximum Operating PressureFlow RateSpecifications MetMinimum Operating TemperatureMaximum Operating TemperatureBore DiameterApplicationSeat MaterialANSI Flange ClassOutlet Connection SizeFlange SizeFor Fluid TypeValve TypeBody MaterialConnection SizeDivision
MFH120E32T600N
Quote Required
TBD
PTFERing Type JointBlock-Bleed1/4" NPT FStainless Steel Lever1500n/aNACE-292045Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex6001/2" NPT F2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E32T900
Quote Required
TBD
PTFERing Type JointBlock-Bleed1/4" NPT FStainless Steel Lever2250n/aAPI 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex9001/2" NPT F2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E32T900F
Quote Required
TBD
GraphoilRing Type JointBlock-Bleed1/4" NPT FStainless Steel Lever2250n/aFire Safe-5410005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex9001/2" NPT F2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E32T900N
Quote Required
TBD
PTFERing Type JointBlock-Bleed1/4" NPT FStainless Steel Lever2250n/aNACE-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex9001/2" NPT F2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F150
Quote Required
TBD
PTFERaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever290n/aAPI 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex1501/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F1500
Quote Required
TBD
PTFERaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever3750n/aAPI 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex15001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F1500F
Quote Required
TBD
GraphoilRaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever3750n/aFire Safe-5410005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex15001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F1500N
Quote Required
TBD
PTFERaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever3750n/aNACE-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex15001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F150F
Quote Required
TBD
GraphoilRaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever290n/aFire Safe-5410005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex1501/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F150N
Quote Required
TBD
PTFERaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever290n/aNACE-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex1501/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F2500
Quote Required
TBD
PTFERaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever6250n/aAPI 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex25001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F2500F
Quote Required
TBD
GraphoilRaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever6250n/aFire Safe-545385Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex25001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F2500N
Quote Required
TBD
PTFERaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever6250n/aNACE-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex25001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F300
Quote Required
TBD
PTFERaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever750n/aAPI 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex3001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F300F
Quote Required
TBD
GraphoilRaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever750n/aFire Safe-5410005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex3001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F300N
Quote Required
TBD
PTFERaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever750n/aNACE-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex3001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F600
Quote Required
TBD
PTFERaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever1500n/aAPI 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex6001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F600F
Quote Required
TBD
GraphoilRaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever1500n/aFire Safe-5410005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex6001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F600N
Quote Required
TBD
PTFERaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever1500n/aNACE-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex6001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division
MFH120E8F900
Quote Required
TBD
PTFERaised Face SpiralBlock-Bleed1/4" NPT FStainless Steel Lever2250n/aAPI 6A, API 607, PRL 2, PSL 2, PSL 3, PSL 4, TAMAP, MESC SPE 77/312-294005Instrument Isolation, In Situ Calibration, Inline Process Isolation, Chemical Injection, Process SamplingDuplex9001/2" NPT F1/2"General Gaseous and Liquid MediaNeedle ValveDuplex1/2" NPT FInstrumentation Products Division