Parker EP series process to instrument valves locate directly onto the process pipeline and facilitate a double block and bleed function for the safe removal of pressure measuring instrument (transmitter or gauge). This is done by isolating the primary block valve, opening the vent to remove the pressure within the instrument , then closing the vent and isolate the secondary block valve. The transmitter (or gauge) can now be safely removed for replacement or calibration in a workshop. The calibrated or replacement transmitter is then re installed and the block valves returned to the open position to resume the instrument function of pressure measurement. The Parker EP series combines 2 block and one bleed valve into a single body. This reduces space, weight, potential leak points and additional costs all associated with the traditional method of combining single flanged block valves to create the double block and bleed function.

The EP series is designed to the EEMUA 182 design code giving the operator and owner assurance of a valve designed to sound engineering practices. Parker offer these valves in many configurations in a wide variety of materials commonly used in industries today. They are manufactured in our UK ISO 9000 compliant facility. The valves are offered with both screwed ends such as NPT Female for direct mount of the instrument or when remote mount is required we offer integral compression fitting ends to facilitate the tubing. The integral compression ends (two ferrule A-LOK or single ferrule CPI) removes the need for NPT, thus removing potential galling, thread tape or sealant, additional leak paths and at the same time reduces the costs associated with buying and installing a separate fitting.

Markets

• Oil & Gas
• Petrochemical
• Chemical
• Industrial Gas

Features/Benefits

• Cavity relief on seats - over-pressure protection of ball cavity
• Integral A-Lok end - reduces leak paths and component costs
• Packing adjustment nut under lever - allows removal of handle without compromising packing integrity and conforms to EEMUA 182
• Tru-Loc™ Mechanical Sealed End Connection - locking mechanism gives 100% security and prevents end connector movement when disconnecting instruments or connectors. This ensures that the ball seat is securely positioned at all times
• Domed nuts - Prevents ingress of environment to stem threads, eliminating corrosion
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandFlange SizeConnection SizeSeat MaterialTechnologyDivisionConnection TypeProduct TypeOperating TemperatureSpecifications MetIndustryApplicationConfigurationFor Fluid TypeFlange Face TypeANSI Flange ClassBody MaterialOperating PressureProduct StyleBore DiameterFlange SizeConfigurationCertificationsConnection TypeFlange Face TypeANSI Flange ClassBody MaterialProduct StyleConnection SizeBore Size
EPBY200E32T600F
Quote Required
TBD
Parker21/2PTFEProcess ControlInstrumentation Products DivisionNPT FDouble Block & Bleed Valve-29 to 232°C, -20 to 450°FAPI 607, EEMUA 182Oil & Gas, Petrochemical, Chemical, Industrial GasInstrument Isolation, Inline Process IsolationBall-Needle-BallCompressed Natural Gas, Fuel, Fire Resistant Fluid, Gasoline, Gylcerin, Hydrogen, Inert Gas, Ketone/Acetone, Lube Oil, Mineral Oil, Nitrogen, Ozone, Petroleum Oil, Solvent, Standard Hydraulic Fluid, Steam, Synthetic Oil, Volatile Gas, Water, Water GlycolRing Type Joint600Duplex1500 PSI, 103 BarFlange x Flange102 InchBall-Needle-BallFire SafeNPT FRing Type Joint600DuplexFlange x Flange1/2 Inch10 MM
EPBY200E32T600N
Quote Required
TBD
Parker21/2PTFEProcess ControlInstrumentation Products DivisionNPT FDouble Block & Bleed Valve-29 to 232°C, -20 to 450°FAPI 607, EEMUA 182Oil & Gas, Petrochemical, Chemical, Industrial GasInstrument Isolation, Inline Process IsolationBall-Needle-BallCompressed Natural Gas, Fuel, Fire Resistant Fluid, Gasoline, Gylcerin, Hydrogen, Inert Gas, Ketone/Acetone, Lube Oil, Mineral Oil, Nitrogen, Ozone, Petroleum Oil, Solvent, Standard Hydraulic Fluid, Steam, Synthetic Oil, Volatile Gas, Water, Water GlycolRing Type Joint600Duplex1500 PSI, 103 BarFlange x Flange102 InchBall-Needle-BallNACENPT FRing Type Joint600DuplexFlange x Flange1/2 Inch10 MM
EPBY200E32T900
Quote Required
TBD
Parker21/2PTFEProcess ControlInstrumentation Products DivisionNPT FDouble Block & Bleed Valve-29 to 232°C, -20 to 450°FAPI 607, EEMUA 182Oil & Gas, Petrochemical, Chemical, Industrial GasInstrument Isolation, Inline Process IsolationBall-Needle-BallCompressed Natural Gas, Fuel, Fire Resistant Fluid, Gasoline, Gylcerin, Hydrogen, Inert Gas, Ketone/Acetone, Lube Oil, Mineral Oil, Nitrogen, Ozone, Petroleum Oil, Solvent, Standard Hydraulic Fluid, Steam, Synthetic Oil, Volatile Gas, Water, Water GlycolRing Type Joint900Duplex2250 PSI, 155 BarFlange x Flange102 InchBall-Needle-BallN/ANPT FRing Type Joint900DuplexFlange x Flange1/2 Inch10 MM
EPBY200E32T900F
Quote Required
TBD
Parker21/2PTFEProcess ControlInstrumentation Products DivisionNPT FDouble Block & Bleed Valve-29 to 232°C, -20 to 450°FAPI 607, EEMUA 182Oil & Gas, Petrochemical, Chemical, Industrial GasInstrument Isolation, Inline Process IsolationBall-Needle-BallCompressed Natural Gas, Fuel, Fire Resistant Fluid, Gasoline, Gylcerin, Hydrogen, Inert Gas, Ketone/Acetone, Lube Oil, Mineral Oil, Nitrogen, Ozone, Petroleum Oil, Solvent, Standard Hydraulic Fluid, Steam, Synthetic Oil, Volatile Gas, Water, Water GlycolRing Type Joint900Duplex2250 PSI, 155 BarFlange x Flange102 InchBall-Needle-BallFire SafeNPT FRing Type Joint900DuplexFlange x Flange1/2 Inch10 MM
EPBY200E32T900N
Quote Required
TBD
Parker21/2PTFEProcess ControlInstrumentation Products DivisionNPT FDouble Block & Bleed Valve-29 to 232°C, -20 to 450°FAPI 607, EEMUA 182Oil & Gas, Petrochemical, Chemical, Industrial GasInstrument Isolation, Inline Process IsolationBall-Needle-BallCompressed Natural Gas, Fuel, Fire Resistant Fluid, Gasoline, Gylcerin, Hydrogen, Inert Gas, Ketone/Acetone, Lube Oil, Mineral Oil, Nitrogen, Ozone, Petroleum Oil, Solvent, Standard Hydraulic Fluid, Steam, Synthetic Oil, Volatile Gas, Water, Water GlycolRing Type Joint900Duplex2250 PSI, 155 BarFlange x Flange102 InchBall-Needle-BallNACENPT FRing Type Joint900DuplexFlange x Flange1/2 Inch10 MM
EPBY200E8F150
Quote Required
TBD
Parker1/21/2PTFEProcess ControlInstrumentation Products DivisionNPT FDouble Block & Bleed Valve-29 to 232°C, -20 to 450°FAPI 607, EEMUA 182Oil & Gas, Petrochemical, Chemical, Industrial GasInstrument Isolation, Inline Process IsolationBall-Needle-BallCompressed Natural Gas, Fuel, Fire Resistant Fluid, Gasoline, Gylcerin, Hydrogen, Inert Gas, Ketone/Acetone, Lube Oil, Mineral Oil, Nitrogen, Ozone, Petroleum Oil, Solvent, Standard Hydraulic Fluid, Steam, Synthetic Oil, Volatile Gas, Water, Water GlycolRaised Face Spiral150Duplex290 PSI, 20 BarFlange x Flange101/2 InchBall-Needle-BallN/ANPT FRaised Face Spiral150DuplexFlange x Flange1/2 Inch10 MM
EPBY200E8F150F
Quote Required
TBD
Parker1/21/2PTFEProcess ControlInstrumentation Products DivisionNPT FDouble Block & Bleed Valve-29 to 232°C, -20 to 450°FAPI 607, EEMUA 182Oil & Gas, Petrochemical, Chemical, Industrial GasInstrument Isolation, Inline Process IsolationBall-Needle-BallCompressed Natural Gas, Fuel, Fire Resistant Fluid, Gasoline, Gylcerin, Hydrogen, Inert Gas, Ketone/Acetone, Lube Oil, Mineral Oil, Nitrogen, Ozone, Petroleum Oil, Solvent, Standard Hydraulic Fluid, Steam, Synthetic Oil, Volatile Gas, Water, Water GlycolRaised Face Spiral150Duplex290 PSI, 20 BarFlange x Flange101/2 InchBall-Needle-BallFire SafeNPT FRaised Face Spiral150DuplexFlange x Flange1/2 Inch10 MM
EPBY200E8F150N
Quote Required
TBD
Parker1/21/2PTFEProcess ControlInstrumentation Products DivisionNPT FDouble Block & Bleed Valve-29 to 232°C, -20 to 450°FAPI 607, EEMUA 182Oil & Gas, Petrochemical, Chemical, Industrial GasInstrument Isolation, Inline Process IsolationBall-Needle-BallCompressed Natural Gas, Fuel, Fire Resistant Fluid, Gasoline, Gylcerin, Hydrogen, Inert Gas, Ketone/Acetone, Lube Oil, Mineral Oil, Nitrogen, Ozone, Petroleum Oil, Solvent, Standard Hydraulic Fluid, Steam, Synthetic Oil, Volatile Gas, Water, Water GlycolRaised Face Spiral150Duplex290 PSI, 20 BarFlange x Flange101/2 InchBall-Needle-BallNACENPT FRaised Face Spiral150DuplexFlange x Flange1/2 Inch10 MM