- Availability & Price
- Search SKU
Filter by attributes
- Bypass Valve Pressure Rating
- Filter Element Type
- Flow Rate
- Indicator Pressure Setting
- Indicator Type
- Micron Rating
- Options
- Port Connection Type
- Seal Material
- Specifications Met
Filter by manufacturer
Medium Pressure Inline Filters CN Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Compressor Lube Oil
Off-line Filter Loops
Machine Tools (Automotive Standard)
Hydrostatic Drive Charge Pumps
Mobile Equipment
Pilot Lines for Servo Controls
Oil Patch Drilling Equipment
Injection Molding
This partial list of applications for Parker CN series filters has a common factor, the need for an economical, medium pressure range filter with excellent fatigue pressure ratings. Prior to the availability of the CN filter, applications such as those listed were restricted by limitations of a spin-on can, or forced into the higher cost range of high pressure filters.
The CN series fills this gap, and now with the newly increased fatigue rating from 550 to 800 psi, the applications are expanded.
Features
· 800 psi fatigue rating (eight times that of a spin-on)
· Diametral (side) seal between head and bowl
· Dust Seal
· Cast aluminum head
· Standard Microglass elements
· Complete performance data disclosure
· Visual, electrical or electrical/visual indicators available
Advantages
· Ability to provide reliable service under tough cyclic operating conditions
· Can be utilized in applications where high pressure filters may have been only option
· Proven reliability in cyclic applications
· Reduced importance of bowl torque
· Prevents contamination from building up on bowl / head threads
· Low profile, lightweight and durable
· Multi-layered design produced high capacity and efficiency
· Reduces pleat bunching, keeps performance consistent
· All pertinent information is provided in an easy-to-compare format
· Check element condition at a glance
· Right style for the application
Benefits
· Reduced downtime due to premature filter failures
· Reduced costs, better “fit” for the application
· No downtime, no leaks
· Performs with “real world” service
· Easier service, no galling
· Less weight, smaller envelop and cleaner appearance
· Great performance value
· Reliable performance throughout element life
· Reduces downtime, maximizes element life
· No hidden deficiencies
· Easy selection of proper filtration
· Optimize element life, prevent bypassing
· Matches your system electrical connections
Read More...Off-line Filter Loops
Machine Tools (Automotive Standard)
Hydrostatic Drive Charge Pumps
Mobile Equipment
Pilot Lines for Servo Controls
Oil Patch Drilling Equipment
Injection Molding
This partial list of applications for Parker CN series filters has a common factor, the need for an economical, medium pressure range filter with excellent fatigue pressure ratings. Prior to the availability of the CN filter, applications such as those listed were restricted by limitations of a spin-on can, or forced into the higher cost range of high pressure filters.
The CN series fills this gap, and now with the newly increased fatigue rating from 550 to 800 psi, the applications are expanded.
Features
· 800 psi fatigue rating (eight times that of a spin-on)
· Diametral (side) seal between head and bowl
· Dust Seal
· Cast aluminum head
· Standard Microglass elements
· Complete performance data disclosure
· Visual, electrical or electrical/visual indicators available
Advantages
· Ability to provide reliable service under tough cyclic operating conditions
· Can be utilized in applications where high pressure filters may have been only option
· Proven reliability in cyclic applications
· Reduced importance of bowl torque
· Prevents contamination from building up on bowl / head threads
· Low profile, lightweight and durable
· Multi-layered design produced high capacity and efficiency
· Reduces pleat bunching, keeps performance consistent
· All pertinent information is provided in an easy-to-compare format
· Check element condition at a glance
· Right style for the application
Benefits
· Reduced downtime due to premature filter failures
· Reduced costs, better “fit” for the application
· No downtime, no leaks
· Performs with “real world” service
· Easier service, no galling
· Less weight, smaller envelop and cleaner appearance
· Great performance value
· Reliable performance throughout element life
· Reduces downtime, maximizes element life
· No hidden deficiencies
· Easy selection of proper filtration
· Optimize element life, prevent bypassing
· Matches your system electrical connections
| Action | Part No. | Availability | Partner Available | Price | UOM | Port Type | For Fluid Type | Pressure Rating | Housing Material | Weight | Compatible Element | Product Type | Mounting Style | Maximum Operating Temperature | Product Style | Division | Options | Seal Material | Indicator Pressure Setting | Port Connection Type | Bypass Valve Pressure Rating | Filter Element Type | Specifications Met | Indicator Type | Flow Rate | Micron Rating | Division |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 80CN110QEEPKS244 | Quote Required | TBD | SAE-24 straight threads | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 69 bar | Aluminum | 12.4 lb | 936602Q | Hydraulic Filter | Inline | 107.0 °C | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Ethylene Propylene | 50 psi (3.4 bar) | SAE-24 straight threads | 50 psi (3.4 bar) | 10Q Microglass | N/A | Port plugged | 100 gpm (379 lpm) | |||||
| 80CN110QEVE2GY324 | Quote Required | TBD | Flange face, SAE 2”, Code 6 | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 1000 psi | Aluminum | 12.4 lb | 936602Q | Hydraulic Filter | Inline | 107.0 °C | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 25 psi (1.7 bar) | Flange face, SAE 2”, Code 6 | 25 psi (1.7 bar) | 10Q Microglass | N/A | Electrical/Visual (DIN43650 Hirschman style connection) | 100 gpm (379 lpm) | |||||
| 80CN110QEVE2KS244 | Quote Required | TBD | SAE-24 straight threads | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 69 bar | Aluminum | 5.62 kg | 936602Q | Hydraulic Filter | Inline | 107.0 °C | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 50 psi (3.4 bar) | SAE-24 straight threads | 50 psi (3.4 bar) | 10Q Microglass | N/A | Electrical/Visual (DIN43650 Hirschman style connection) | 100 gpm (379 lpm) | |||||
| 80CN110QEVE2KY324 | Quote Required | TBD | Flange face, SAE 2”, Code 6 | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 1000 psi | Aluminum | 12.4 lb | 936602Q | Hydraulic Filter | Inline | 107.0 °C | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 50 psi (3.4 bar) | Flange face, SAE 2”, Code 6 | 50 psi (3.4 bar) | 10Q Microglass | N/A | Electrical/Visual (DIN43650 Hirschman style connection) | 100 gpm (379 lpm) | |||||
| 80CN110QEVM2GN324 | Quote Required | TBD | 2” NPT | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 1000 psi | Aluminum | 12.4 lb | 936602Q | Hydraulic Filter | Inline | 225.0 °F | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 25 psi (1.7 bar) | 2” NPT | 25 psi (1.7 bar) | 10Q Microglass | N/A | Visual automatic reset | 100 gpm (379 lpm) | |||||
| 80CN110QEVM2GY324 | Quote Required | TBD | Flange face, SAE 2”, Code 6 | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 1000 psi | Aluminum | 12.4 lb | 936602Q | Hydraulic Filter | Inline | 225.0 °F | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 25 psi (1.7 bar) | Flange face, SAE 2”, Code 6 | 25 psi (1.7 bar) | 10Q Microglass | N/A | Visual automatic reset | 100 gpm (379 lpm) | 10 µm | ||||
| 80CN110QEVM2KN244 | Quote Required | TBD | 1-1/2” NPT | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 69 bar | Aluminum | 12.4 lb | 936602Q | Hydraulic Filter | Inline | 225.0 °F | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 50 psi (3.4 bar) | 1-1/2” NPT | 50 psi (3.4 bar) | 10Q Microglass | N/A | Visual automatic reset | 100 gpm (379 lpm) | |||||
| 80CN110QEVM2KS244 | Quote Required | $879.30 | EA | SAE-24 straight threads | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 69 bar | Aluminum | 5.62 kg | 936602Q | Hydraulic Filter | Inline | 107.0 °C | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 50 psi (3.4 bar) | SAE-24 straight threads | 50 psi (3.4 bar) | 10Q Microglass | N/A | Visual automatic reset | 100 gpm (379 lpm) | ||||
| 80CN110QEVM2KY324 | Quote Required | $956.86 | EA | Flange face, SAE 2”, Code 6 | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 1000 psi | Aluminum | 12.4 lb | 936602Q | Hydraulic Filter | Inline | 107.0 °C | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 50 psi (3.4 bar) | Flange face, SAE 2”, Code 6 | 50 psi (3.4 bar) | 10Q Microglass | N/A | Visual automatic reset | 100 gpm (379 lpm) | ||||
| 80CN110QEVM3KG244 | Quote Required | TBD | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 2.5 bar | G1½" | 3.5 bar (50 psi) | 10QE Ecoglass | N/A | Visual automatic reset | 400 l/min (105 gal/min) | 10 µm | ||||||||||||||
| 80CN110QEVM3KG324 | Quote Required | TBD | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 2.5 bar | G2" | 3.5 bar (50 psi) | 10QE Ecoglass | N/A | Visual automatic reset | 520 l/min (140 gal/min) | 10 µm | ||||||||||||||
| 80CN110QEVM3KR324 | Quote Required | TBD | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 2.5 bar | SAE flange 2" 3000-M | 3.5 bar (50 psi) | 10QE Ecoglass | N/A | Visual automatic reset | 520 l/min (140 gal/min) | 10 µm | ||||||||||||||
| 80CN110QEVPKN324 | Quote Required | TBD | 2” NPT | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 1000 psi | Aluminum | 5.62 kg | 936602Q | Hydraulic Filter | Inline | 107.0 °C | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 50 psi (3.4 bar) | 2” NPT | 50 psi (3.4 bar) | 10Q Microglass | N/A | Port plugged | 100 gpm (379 lpm) | |||||
| 80CN110QEVPKY324 | Quote Required | TBD | Flange face, SAE 2”, Code 6 | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 69 bar | Aluminum | 12.4 lb | 936602Q | Hydraulic Filter | Inline | 225.0 °F | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 50 psi (3.4 bar) | Flange face, SAE 2”, Code 6 | 50 psi (3.4 bar) | 10Q Microglass | N/A | Port plugged | 100 gpm (379 lpm) | |||||
| 80CN110QEVT1KG244 | Quote Required | TBD | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 2.5 bar | G1½" | 3.5 bar (50 psi) | 10QE Ecoglass | CE marked indicator | Electrical indicator with 7/8-14UNF-2A thread | 400 l/min (105 gal/min) | 10 µm | ||||||||||||||
| 80CN110QEVT1KG324 | Quote Required | TBD | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Fluorocarbon | 2.5 bar | G2" | 3.5 bar (50 psi) | 10QE Ecoglass | CE marked indicator | Electrical indicator with 7/8-14UNF-2A thread | 520 l/min (140 gal/min) | 10 µm | ||||||||||||||
| 80CN120QBM3KG241 | Quote Required | TBD | Engine Mobile Hydraulic and Fuel Filtration Division | No drain | Nitrile | 2.5 bar | G1½" | 3.5 bar (50 psi) | 20Q Microglass | N/A | Visual automatic reset | 440 l/min (116 gal/min) | 20 µm | ||||||||||||||
| 80CN120QBPGL324 | Quote Required | TBD | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Nitrile | No indicator | SAE flange 2" 3000 | 1.7 bar (25 psi) | 20Q Microglass | N/A | Plugged Ports | 400 l/min (105 gal/min) | 20 µm | Hydraulic & Industrial Process Filtration Division EMEA | ||||||||||||
| 80CN120QBT1KG321 | Quote Required | TBD | Engine Mobile Hydraulic and Fuel Filtration Division | No drain | Nitrile | 2.5 bar | G2" | 3.5 bar (50 psi) | 20Q Microglass | CE marked indicator | Electrical indicator with 7/8-14UNF-2A thread | 520 l/min (140 gal/min) | 20 µm | ||||||||||||||
| 80CN120QEBE2GS244 | Quote Required | TBD | SAE-24 straight threads | Mineral, Petroleum and Polyalphaolefin (PAO) based fluids | 69 bar | Aluminum | 12.4 lb | 936715Q | Hydraulic Filter | Inline | 107.0 °C | Hydraulic Filter | Engine Mobile Hydraulic and Fuel Filtration Division | Drain port | Nitrile | 25 psi (1.7 bar) | SAE-24 straight threads | 25 psi (1.7 bar) | 20Q Microglass | N/A | Electrical/Visual (DIN43650 Hirschman style connection) | 100 gpm (379 lpm) |