• Availability & Price
  • Search SKU
Filter by attributes
  • Bypass Valve Pressure Rating
  • Connection Type
  • Filter Element
  • Filter Element Type
  • Flow Capacity
  • Flow Rate
  • Height
  • Indicator Pressure Setting
  • Indicator Type
  • Micron Rating
More Filters...
Filter by manufacturer
Manufacturers

Medium Pressure In-Line Filter - 45M Series

Picture for category Medium Pressure In-Line Filter - 45M Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The 45M/45 Eco Series utilizes a cast iron head and steel bowl design and can be specified with Microglass lll or Ecoglass lll filter media. Filter bowl is designed for rapid element replacement. ECO Series elements reduces waste by over 50% due to the reusable element core.

Features and Benefits
• Cast iron head and steel bowl offering reliable filtration in all conditions including engine rooms and mins

• Check element condition at a glance with visual, electrical or electronic indicators available to suit a wide range of applications

• Test points in the filter head for quick testing and maintenance

• Can be specified with Microglass III or Ecoglass III filter media:

Microglass III:
Reinforced Microglass III replacement elements have a multi-layered design for high capacity and efficiency for great performance and value throughout the life of the element.

EcoGlass III:
Coreless Ecoglass III replacement elements utilized a reusable element core which reduces waste by over 50% lowering replacement and disposal costs. Eco adaptors are available to retrofit coreless design to housings already installed.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandMounting TypeDivisionDivisionTechnologyProduct TypeFor Fluid TypeSpecifications MetIndustryHousing MaterialProduct SeriesOperating PressureApplicationOperating TemperatureSeal MaterialFilter ElementIndicator TypeMicron RatingFilter Element TypeIndicator Pressure SettingBypass Valve Pressure RatingConnection TypeHeightFlow RateFlow CapacityPort Connection TypeTemperature CharacteristicsOptions
45M310QBPKG161S13
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Off-road MachineryIron/Steel45M Series40 barIndustrial Power Units-40 to 100 °C (Seal Material Nitrile)Nitrile10Q MicroglassNo indicator, port plugged10 µm10Q MicroglassNo indicator3.5 barG1450 mm190 l/min190 l/minG1-40 / +100°CHFC version
45M310QBPKG201
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Industrial Manufacturing EquipmentIron/Steel45M Series40 barMobile Construction Equipment-40 to 100 °C (Seal Material Nitrile)Nitrile10Q MicroglassNo indicator, port plugged10 µm10Q MicroglassNo indicator3.5 barG1¼450 mm210 l/min210 l/minG1¼-40 / +100°CStandard
45M310QBPKG241
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Power GenerationIron/Steel45M Series40 barForestry Equipment-40 to 100 °C (Seal Material Nitrile)Nitrile10Q MicroglassNo indicator, port plugged10 µm10Q MicroglassNo indicator3.5 barG1½450 mm250 l/min230 l/minG1½-40 / +100°CStandard
45M310QBPKR241
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Industrial Manufacturing EquipmentIron/Steel45M Series40 barForestry Equipment-40 to 100 °C (Seal Material Nitrile)Nitrile10Q MicroglassNo indicator, port plugged10 µm10Q MicroglassNo indicator3.5 bar1½" SAE-3000M450 mm250 l/min230 l/min1½" SAE-3000M-40 / +100°CStandard
45M310QBPXG162
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Off-road MachineryIron/Steel45M Series40 barMobile Construction Equipment-20 to 120 °C (Seal Material Fluoroelastomer)Nitrile10Q MicroglassNo indicator, port plugged10 µm10Q MicroglassNo indicatorNo BypassG1450 mm190 l/min190 l/minG1-40 / +100°CNo bypass
45M310QBPXG202
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Industrial Manufacturing EquipmentIron/Steel45M Series40Industrial Power Units-40 to 100 °C (Seal Material Nitrile)Nitrile10Q MicroglassNo indicator, port plugged10 µm10Q MicroglassNo indicatorNo BypassG1¼450 mm210 l/min210 l/minG1¼-40 / +100°CNo bypass
45M310QBPXG242
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Industrial Manufacturing EquipmentIron/Steel45M Series40Industrial Power Units-40 to 100 °C (Seal Material Nitrile)Nitrile10Q MicroglassNo indicator, port plugged10 µm10Q MicroglassNo indicatorNo BypassG1½450 mm230 l/min230 l/minG1½-40 / +100°CNo bypass
45M310QBPXR242
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Industrial Manufacturing EquipmentIron/Steel45M Series40 barIndustrial Power Units-20 to 120 °C (Seal Material Fluoroelastomer)Nitrile10Q MicroglassNo indicator, port plugged10 µm10Q MicroglassNo indicatorNo Bypass1½" SAE-3000M450 mm230 l/min230 l/min1½" SAE-3000M-40 / +100°CNo bypass
45M310QBT1KG241
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Off-road MachineryIron/Steel45M Series40 barForestry Equipment-20 to 120 °C (Seal Material Fluoroelastomer)Nitrile10Q MicroglassElectrical NO/NC10 µm10Q Microglass2.53.5 barG1½450 mm250 l/min230 l/minG1½-40 / +100°CStandard
45M310QBT1NG242
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Industrial Manufacturing EquipmentIron/Steel45M Series40Industrial Power Units-20 to 120 °C (Seal Material Fluoroelastomer)Nitrile10Q MicroglassElectrical NO/NC10 µm10Q Microglass7.0No BypassG1½450 mm230 l/min230 l/minG1½-40 / +100°CNo bypass
45M310QEBPKG161
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Industrial Manufacturing EquipmentIron/Steel45M Series40Forestry Equipment-40 to 100 °C (Seal Material Nitrile)Nitrile10QE EcoglassNo indicator, port plugged10 µm10QE EcoglassNo indicator3.5 barG1450 mm190 l/min190 l/minG1-40 / +100°CStandard
45M310QEBPKG201
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Off-road MachineryIron/Steel45M Series40Industrial Power Units-40 to 100 °C (Seal Material Nitrile)Nitrile10QE EcoglassNo indicator, port plugged10 µm10QE EcoglassNo indicator3.5 barG1¼450 mm210 l/min210 l/minG1¼-40 / +100°CStandard
45M310QEBPKG241
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Power GenerationIron/Steel45M Series40 barMobile Construction Equipment-40 to 100 °C (Seal Material Nitrile)Nitrile10QE EcoglassNo indicator, port plugged10 µm10QE EcoglassNo indicator3.5 barG1½450 mm250 l/min230 l/minG1½-40 / +100°CStandard
45M310QEBPXG162
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Industrial Manufacturing EquipmentIron/Steel45M Series40Industrial Power Units-20 to 120 °C (Seal Material Fluoroelastomer)Nitrile10QE EcoglassNo indicator, port plugged10 µm10QE EcoglassNo indicatorNo BypassG1450 mm190 l/min190 l/minG1-40 / +100°CNo bypass
45M310QEBT1KG241
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Industrial Manufacturing EquipmentIron/Steel45M Series40Industrial Power Units-40 to 100 °C (Seal Material Nitrile)Nitrile10QE EcoglassElectrical NO/NC10 µm10QE Ecoglass2.53.5 barG1½450 mm230 l/min230 l/minG1½-40 / +100°CStandard
45M310QVM3KG241
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Power GenerationIron/Steel45M Series40 barIndustrial Power Units-20 to 120 °C (Seal Material Fluoroelastomer)Fluoroelastomer10Q MicroglassVisual10 µm10Q MicroglassNo indicator3.5 barG1½450 mm230 l/min230 l/minG1½-20 / +120°CStandard
45M320QBF1KG161
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Industrial Manufacturing EquipmentIron/Steel45M Series40Industrial Power Units-40 to 100 °C (Seal Material Nitrile)Nitrile20Q MicroglassElectronic 4 LED, PNP, NO20 µm20Q Microglass2.53.5 barG1450 mm200 l/min200 l/minG1-40 / +100°CStandard
45M320QBPKG161
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Power GenerationIron/Steel45M Series40 barForestry Equipment-20 to 120 °C (Seal Material Fluoroelastomer)Nitrile20Q MicroglassNo indicator, port plugged20 µm20Q MicroglassNo indicator3.5 barG1450 mm200 l/min200 l/minG1-40 / +100°CStandard
45M320QBPKG201
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Industrial Manufacturing EquipmentIron/Steel45M Series40Industrial Power Units-40 to 100 °C (Seal Material Nitrile)Nitrile20Q MicroglassNo indicator, port plugged20 µm20Q MicroglassNo indicator3.5 barG1¼450 mm230 l/min230 l/minG1¼-40 / +100°CStandard
45M320QBPKG241
Quote Required
TBD
ParkerInlineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Off-road MachineryIron/Steel45M Series40 barMobile Construction Equipment-20 to 120 °C (Seal Material Fluoroelastomer)Nitrile20Q MicroglassNo indicator, port plugged20 µm20Q MicroglassNo indicator3.5 barG1½450 mm280 l/min250 l/minG1½-40 / +100°CStandard