- Availability & Price
- Search SKU
Filter by attributes
- Bypass Valve Pressure Rating
- Connection Type
- Filter Element
- Filter Element Type
- Flow Capacity
- Flow Rate
- Height
- Indicator Pressure Setting
- Indicator Type
- Micron Rating
Filter by manufacturer
Medium Pressure In-Line Filter - 45M Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The 45M/45 Eco Series utilizes a cast iron head and steel bowl design and can be specified with Microglass lll or Ecoglass lll filter media. Filter bowl is designed for rapid element replacement. ECO Series elements reduces waste by over 50% due to the reusable element core.
Features and Benefits
• Cast iron head and steel bowl offering reliable filtration in all conditions including engine rooms and mins
• Check element condition at a glance with visual, electrical or electronic indicators available to suit a wide range of applications
• Test points in the filter head for quick testing and maintenance
• Can be specified with Microglass III or Ecoglass III filter media:
Microglass III:
Reinforced Microglass III replacement elements have a multi-layered design for high capacity and efficiency for great performance and value throughout the life of the element.
EcoGlass III:
Coreless Ecoglass III replacement elements utilized a reusable element core which reduces waste by over 50% lowering replacement and disposal costs. Eco adaptors are available to retrofit coreless design to housings already installed.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Features and Benefits
• Cast iron head and steel bowl offering reliable filtration in all conditions including engine rooms and mins
• Check element condition at a glance with visual, electrical or electronic indicators available to suit a wide range of applications
• Test points in the filter head for quick testing and maintenance
• Can be specified with Microglass III or Ecoglass III filter media:
Microglass III:
Reinforced Microglass III replacement elements have a multi-layered design for high capacity and efficiency for great performance and value throughout the life of the element.
EcoGlass III:
Coreless Ecoglass III replacement elements utilized a reusable element core which reduces waste by over 50% lowering replacement and disposal costs. Eco adaptors are available to retrofit coreless design to housings already installed.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Brand | Technology | Mounting Type | Division | Division | Product Type | For Fluid Type | Specifications Met | Application | Housing Material | Product Series | Operating Pressure | Industry | Operating Temperature | Seal Material | Options | Filter Element | Indicator Type | Port Connection Type | Micron Rating | Filter Element Type | Connection Type | Indicator Pressure Setting | Bypass Valve Pressure Rating | Temperature Characteristics | Height | Flow Rate | Flow Capacity |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 45M410QBPKG241 | Quote Required | TBD | Parker | Filtration | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Forestry Equipment | Iron/Steel | 45M Series | 40 bar | Power Generation | -40 to 100 °C (Seal Material Nitrile) | Nitrile | Standard | 10Q Microglass | No indicator, port plugged | G1½ | 10 µm | 10Q Microglass | G1½ | No indicator | 3.5 bar | -40 / +100°C | 550 mm | 240 l/min | 240 l/min | ||
| 45M410QEBM3KG201 | Quote Required | TBD | Parker | Hydraulics | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Industrial Power Units | Iron/Steel | 45M Series | 40 bar | Power Generation | -40 to 100 °C (Seal Material Nitrile) | Nitrile | Standard | 10QE Ecoglass | Visual | G1¼ | 10 µm | 10QE Ecoglass | G1¼ | 2.5 | 3.5 bar | -40 / +100°C | 550 mm | 220 l/min | 220 l/min | ||
| 45M410QEBM3KG241 | Quote Required | TBD | Parker | Hydraulics | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Mobile Construction Equipment | Iron/Steel | 45M Series | 40 bar | Power Generation | -40 to 100 °C (Seal Material Nitrile) | Nitrile | Standard | 10QE Ecoglass | Visual | G1½ | 10 µm | 10QE Ecoglass | G1½ | 2.5 | 3.5 bar | -40 / +100°C | 550 mm | 240 l/min | 240 l/min | ||
| 45M410QEBPKG201 | Quote Required | TBD | Parker | Hydraulics | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Industrial Power Units | Iron/Steel | 45M Series | 40 | Industrial Manufacturing Equipment | -40 to 100 °C (Seal Material Nitrile) | Nitrile | Standard | 10QE Ecoglass | No indicator, port plugged | G1¼ | 10 µm | 10QE Ecoglass | G1¼ | No indicator | 3.5 bar | -40 / +100°C | 550 mm | 220 l/min | 220 l/min | ||
| 45M410QEBPKG241 | Quote Required | TBD | Parker | Filtration | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Industrial Power Units | Iron/Steel | 45M Series | 40 bar | Off-road Machinery | -20 to 120 °C (Seal Material Fluoroelastomer) | Nitrile | Standard | 10QE Ecoglass | No indicator, port plugged | G1½ | 10 µm | 10QE Ecoglass | G1½ | No indicator | 3.5 bar | -40 / +100°C | 550 mm | 240 l/min | 240 l/min | ||
| 45M410QEBPKR241 | Quote Required | TBD | Parker | Hydraulics | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Industrial Power Units | Iron/Steel | 45M Series | 40 | Industrial Manufacturing Equipment | -40 to 100 °C (Seal Material Nitrile) | Nitrile | Standard | 10QE Ecoglass | No indicator, port plugged | 1½" SAE-3000M | 10 µm | 10QE Ecoglass | 1½" SAE-3000M | No indicator | 3.5 bar | -40 / +100°C | 550 mm | 240 l/min | 240 l/min | ||
| 45M420QBF1KG241 | Quote Required | TBD | Parker | Hydraulics | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Industrial Power Units | Iron/Steel | 45M Series | 40 | Industrial Manufacturing Equipment | -20 to 120 °C (Seal Material Fluoroelastomer) | Nitrile | Standard | 20Q Microglass | Electronic 4 LED, PNP, NO | G1½ | 20 µm | 20Q Microglass | G1½ | 2.5 | 3.5 bar | -40 / +100°C | 550 mm | 260 l/min | 260 l/min | ||
| 45M420QBPHG241 | Quote Required | TBD | Parker | Filtration | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Industrial Power Units | Iron/Steel | 45M Series | 40 bar | Power Generation | -40 to 100 °C (Seal Material Nitrile) | Nitrile | Standard | 20Q Microglass | No indicator, port plugged | G1½ | 20 µm | 20Q Microglass | G1½ | No indicator | 2.0 bar | -40 / +100°C | 550 mm | 260 l/min | 260 l/min | ||
| 45M420QBPKG201 | Quote Required | TBD | Parker | Hydraulics | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Industrial Power Units | Iron/Steel | 45M Series | 40 | Off-road Machinery | -40 to 100 °C (Seal Material Nitrile) | Nitrile | Standard | 20Q Microglass | No indicator, port plugged | G1¼ | 20 µm | 20Q Microglass | G1¼ | No indicator | 3.5 bar | -40 / +100°C | 550 mm | 250 l/min | 230 l/min | ||
| 45M420QBPKG241 | Quote Required | TBD | Parker | Hydraulics | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Industrial Power Units | Iron/Steel | 45M Series | 40 | Industrial Manufacturing Equipment | -40 to 100 °C (Seal Material Nitrile) | Nitrile | Standard | 20Q Microglass | No indicator, port plugged | G1½ | 20 µm | 20Q Microglass | G1½ | No indicator | 3.5 bar | -40 / +100°C | 550 mm | 260 l/min | 260 l/min | ||
| 45M420QBT1KG161 | Quote Required | TBD | Parker | Hydraulics | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Industrial Power Units | Iron/Steel | 45M Series | 40 | Industrial Manufacturing Equipment | -40 to 100 °C (Seal Material Nitrile) | Nitrile | Standard | 20Q Microglass | Electrical NO/NC | G1 | 20 µm | 20Q Microglass | G1 | 2.5 | 3.5 bar | -40 / +100°C | 550 mm | 200 l/min | 200 l/min | ||
| 45M420QEBM3KG241 | Quote Required | TBD | Parker | Filtration | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Forestry Equipment | Iron/Steel | 45M Series | 40 bar | Off-road Machinery | -40 to 100 °C (Seal Material Nitrile) | Nitrile | Standard | 20QE Ecoglass | Visual | G1½ | 20 µm | 20QE Ecoglass | G1½ | 2.5 | 3.5 bar | -40 / +100°C | 550 mm | 260 l/min | 260 l/min | ||
| 45M420QEBPKG201 | Quote Required | TBD | Parker | Hydraulics | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Industrial Power Units | Iron/Steel | 45M Series | 40 | Industrial Manufacturing Equipment | -40 to 100 °C (Seal Material Nitrile) | Nitrile | Standard | 20QE Ecoglass | No indicator, port plugged | G1¼ | 20 µm | 20QE Ecoglass | G1¼ | No indicator | 3.5 bar | -40 / +100°C | 550 mm | 230 l/min | 230 l/min | ||
| 45M420QEBPKG241 | Quote Required | TBD | Parker | Hydraulics | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Industrial Power Units | Iron/Steel | 45M Series | 40 bar | Power Generation | -20 to 120 °C (Seal Material Fluoroelastomer) | Nitrile | Standard | 20QE Ecoglass | No indicator, port plugged | G1½ | 20 µm | 20QE Ecoglass | G1½ | No indicator | 3.5 bar | -40 / +100°C | 550 mm | 260 l/min | 260 l/min | ||
| 45M420QEBPXG242 | Quote Required | TBD | Parker | Hydraulics | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Mobile Construction Equipment | Iron/Steel | 45M Series | 40 bar | Off-road Machinery | -20 to 120 °C (Seal Material Fluoroelastomer) | Nitrile | No bypass | 20QE Ecoglass | No indicator, port plugged | G1½ | 20 µm | 20QE Ecoglass | G1½ | No indicator | No Bypass | -40 / +100°C | 550 mm | 260 l/min | 260 l/min | ||
| 45M420QEBT1KG161 | Quote Required | TBD | Parker | Hydraulics | Inline | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic Filter | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | Industrial Power Units | Iron/Steel | 45M Series | 40 | Industrial Manufacturing Equipment | -40 to 100 °C (Seal Material Nitrile) | Nitrile | Standard | 20QE Ecoglass | Electrical NO/NC | G1 | 20 µm | 20QE Ecoglass | G1 | 2.5 | 3.5 bar | -40 / +100°C | 550 mm | 210 l/min | 200 l/min |