• Availability & Price
  • Search SKU
Filter by attributes
  • Maximum Flow Rate (m³/h)
More Filters...
Filter by manufacturer
Manufacturers

LV Series Paint Compatible Compressed Air Filter

Picture for category LV Series Paint Compatible Compressed Air Filter

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

A high quality finish is essential, especially in the automotive industry, where blisters, craters and loss of adhesion are the common results of compressed air contamination. These problems can cause costly product spoilage, expensive re-work and loss of valuable production.

Working closely for many years with automotive manufacturers and the producers of water and solvent based paints, Parker ZANDER understands the industry and its special needs. Ordinary filters may clean compressed air but can release silicone into the compressed air stream from lubricants, cleaning agents, 'o'-rings or other component parts. Silicone is recognized as the worst possible contaminant in paint spraying applications and Parker ZANDER assemble the LV Series Paint Compatible Filters in a silicone-free atmosphere and manufacturing area using only certified silicone-free components.

Features and Benefits
• Guaranteed to be silicone-free

• Designed to match the exacting requirements of the automotive industry

• Remove dirt, water and oil to the highest ISO 8573.1 industry standard

• Independently tested

Sizing and Selection
Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceDivisionMaximum Operating PressureBrandWeightWidthHeightPort SizeMaximum Flow RateCompatible ElementMaximum Flow Rate (m³/h)
F100_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander3538401780DN20010889 CFM at 100 psig3075_/LV18500 @ 7 barg
F120_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander4509401940DN25013066 CFM at 100 psig3075_/LV22200 @ 7 barg
F160_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander4609401940DN25017422 CFM at 100 psig3075_/LV29600 @ 7 barg
F17_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander383801280DN801089 CFM at 100 psig3075_/LV1850 @ 7 barg
F19_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander444401320DN801719 CFM at 100 psig5075_/LV2920 @ 7 barg
F20_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander1015001440DN1002178 CFM at 100 psig3075_/LV3700 @ 7 barg
F200_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander5209401970DN30021777 CFM at 100 psig3075_/LV37000 @ 7 barg
F30_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander1025001440DN1003267 CFM at 100 psig3075_/LV5550 @ 7 barg
F40_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander1366401590DN1504355 CFM at 100 psig3075_/LV7400 @ 7 barg
F60_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander2207901650DN1506533 CFM at 100 psig3075_/LV11100 @ 7 barg
F80_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander2307901730DN2008711 CFM at 100 psig3075_/LV14800 @ 7 barg
G11_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander4.5130488G 1177 CFM at 100 psig2020_/LV300 @ 7 barg
G12_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander5.3130590G 1-1/2277 CFM at 100 psig2030_/LV470 @ 7 barg
G13_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander6.4130790G 1-1/2412 CFM at 100 psig2050_/LV700 @ 7 barg
G14_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander9.1164847G 2553 CFM at 100 psig3050_/LV940 @ 7 barg
G17_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander121641100G 2853 CFM at 100 psig3075_/LV1450 @ 7 barg
G19_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander272501230G 31413 CFM at 100 psig5075_/LV2400 @ 7 barg
G2_H/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander0.661150G 1/418 CFM at 100 psig1030_/LV30 @ 7 barg
G3_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander187285G 1/430 CFM at 100 psig1050_/LV50 @ 7 barg
G5_DH/LV
Quote Required
TBD
Gas Separation and Filtration Division EMEA16Zander187285G 3/841 CFM at 100 psig1070_/LV70 @ 7 barg