*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The GA Series utilizes an aluminium housing design and can be specified with Microglass, Ecoglass (Leif), Cellulose or Wire mesh filter media.
Supplied with magnetic pre-filtration, making it ideal for use in hydraulic and lubrication oil systems, that can contain high levels of iron and other ferrous contaminants.
GA filters make use of the In-to-Out filter principle, which means there is no possibility for contaminated oil to leak back into the system.
Available with optional Visual or Visual/Electronic differential pressure indicators. Maximum nominal flow 320 l/min and maximum working pressure 30 bar.
Applications:
• Gearboxes
• Bypass filtration
• Stone crushers
• Lube oil systems
• Metal cutting equipment
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Supplied with magnetic pre-filtration, making it ideal for use in hydraulic and lubrication oil systems, that can contain high levels of iron and other ferrous contaminants.
GA filters make use of the In-to-Out filter principle, which means there is no possibility for contaminated oil to leak back into the system.
Available with optional Visual or Visual/Electronic differential pressure indicators. Maximum nominal flow 320 l/min and maximum working pressure 30 bar.
Applications:
• Gearboxes
• Bypass filtration
• Stone crushers
• Lube oil systems
• Metal cutting equipment
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Division | Operating Temperature | Housing Material | Mounting Type | Pressure Rating | Bypass Valve Pressure Rating | Seal Material | Flow Rate | Filter Element Type | For Use With | Indicator Pressure Setting | Options | Connection Type | Indicator Type | Micron Rating |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| GA610QLBE3EG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 °C | Aluminium | Inline | 30 bar | 1.5 bar | Nitrile | 0 to 150 l/min | 040W Wiremesh | GA 1-90 | 1.2 bar | With magnets | G1 | Vis/Electr. on right side, left side plugged | 40 µm | ||
| GA620QLBP2HG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 | Aluminium | Inline | 30 | 1.5 bar | Nitrile | 0 to 150 l/min | 040W Wiremesh | GA 1-90 | No indicator | With magnets | G1 | No indicator, ports plugged L+R | 40 µm | ||
| GA6XXXBP2EG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | 1.5 bar | Nitrile | 0 to 220 l/min | 10QL Ecoglass | GA 2-230 | 1.2 bar | With magnets | G1½ | Visual on right side, left side plugged | 10 µm | ||||||
| GA702QBE3EG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 | Aluminium | Inline | 30 | 1.5 bar | Fluoroelastomer | 0 to 150 l/min | 040W Wiremesh | GA 1-90 | No indicator | With magnets | G1 | No indicator, ports plugged L+R | 40 µm | ||
| GA7040WBD3EG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 °C | Aluminium | Inline | 30 bar | 1.5 bar | Nitrile | 0 to 75 l/min | 05Q Microglass | GA 1-90 | No indicator | With magnets | G1 | No indicator, ports plugged L+R | 5 µm | ||
| GA7040WBE3HG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 °C | Aluminium | Inline | 30 bar | No Bypass | Nitrile | 0 to 75 l/min | 05Q Microglass | GA 1-90 | No indicator | No magnets | G1 | No indicator, ports plugged L+R | 5 µm | ||
| GA7040WBP2BG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 °C | Aluminium | Inline | 30 bar | 0.8 bar | Nitrile | 0 to 85 l/min | 10Q Microglass | GA 1-90 | 0.7 bar | With magnets | G1 | Visual on right side, left side plugged | 10 µm | ||
| GA7040WBP2EG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 | Aluminium | Inline | 30 | 0.8 bar | Nitrile | 0 to 85 l/min | 10Q Microglass | GA 1-90 | No indicator | With magnets | G1 | No indicator, ports plugged L+R | 10 µm | ||
| GA7040WBP2XG242 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 °C | Aluminium | Inline | 30 bar | 1.5 bar | Nitrile | 0 to 85 l/min | 10Q Microglass | GA 1-90 | No indicator | With magnets | G1 | No indicator, ports plugged L+R | 10 µm | ||
| GA7040WBP2XG246 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 | Aluminium | Inline | 30 | 1.5 bar | Nitrile | 0 to 85 l/min | 10QL Ecoglass | GA 1-90 | 1.2 bar | With magnets | G1 | Visual on right side, left side plugged | 10 µm | ||
| GA705QBE3EG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 | Aluminium | Inline | 30 | 1.5 bar | Nitrile | 0 to 100 l/min | 20Q Microglass | GA 1-90 | No indicator | With magnets | G1 | No indicator, ports plugged L+R | 20 µm | ||
| GA705QLBD3HG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 °C | Aluminium | Inline | 30 bar | 1.5 bar | Nitrile | 0 to 180 l/min | 040W Wiremesh | GA 1-120 | 1.2 bar | With magnets | G1¼ | Visual on right side, left side plugged | 40 µm | ||
| GA705QLBE3EG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 °C | Aluminium | Inline | 30 bar | 0.8 bar | Nitrile | 0 to 180 l/min | 040W Wiremesh | GA 1-120 | No indicator | With magnets | G1¼ | No indicator, ports plugged L+R | 40 µm | ||
| GA7060WBP2EG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | 1.5 bar | Nitrile | 0 to 220 l/min | 10QL Ecoglass | GA 2-230 | 1.2 bar | With magnets | G1½ | Vis/Electr. on right side, left side plugged | 10 µm | ||||||
| GA710CBD3EG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 °C | Aluminium | Inline | 30 bar | 0.8 bar | Nitrile | 0 to 110 l/min | 05QL Ecoglass | GA 1-120 | 0.7 bar | With magnets | G1¼ | Vis/Electr. on right side, left side plugged | 5 µm | ||
| GA710CBP2BG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 | Aluminium | Inline | 30 | 1.5 bar | Nitrile | 0 to 110 l/min | 05QL Ecoglass | GA 1-120 | 1.2 bar | With magnets | G1¼ | Vis/Electr. on right side, left side plugged | 5 µm | ||
| GA710QBD3BG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 | Aluminium | Inline | 30 | 1.5 bar | Nitrile | 0 to 180 l/min | 10C Cellulose | GA 1-120 | 1.2 bar | With magnets | G1¼ | Visual on right side, left side plugged | 10 µm | ||
| GA710QBD3EG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 °C | Aluminium | Inline | 30 bar | 0.8 bar | Nitrile | 0 to 180 l/min | 10C Cellulose | GA 1-120 | 0.7 bar | With magnets | G1¼ | Vis/Electr. on right side, left side plugged | 10 µm | ||
| GA710QBE3EG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 °C | Aluminium | Inline | 30 bar | 1.5 bar | Nitrile | 0 to 180 l/min | 10C Cellulose | GA 1-120 | 1.2 bar | With magnets | G1¼ | Vis/Electr. on right side, left side plugged | 10 µm | ||
| GA710QBP2BG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | -40 to 100 °C | Aluminium | Inline | 30 bar | 0.8 bar | Nitrile | 0 to 180 l/min | 10C Cellulose | GA 1-120 | No indicator | With magnets | G1¼ | No indicator, ports plugged L+R | 10 µm |