• Availability & Price
  • Search SKU
Filter by attributes
  • Isolation Chamber
  • Liquid Inlet Location
  • Piston Air Drive
  • Pressure Ratio (Air/Water)
  • Seal Type
More Filters...
Filter by manufacturer
Manufacturers

Liquid Pump, 6 " Air Driven - ASL Series

Picture for category Liquid Pump, 6 " Air Driven - ASL Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker Autoclave's ASL Series is a standard 6” piston, air driven liquid pump. Parker Autoclave has designed a full line of high pressure liquid pumps that, with only a few option changes, cover most applications for air-operated pumps. Easy-to-understand product features permit system designers to spend their time thinking about what the ultimate use for the pump will be, not needing to learn how to read the catalog or price list to make sure that the best selection can be made.

These air-driven liquid pumps are designed to include most competitive options and require only the basic of choices be made. Parker Autoclave pumps are designed to work, and work well. The ASL Series of pumps are grouped around the 6 inch air piston and then by the actual ratio of air to hydraulic pressure. Inside that group are both single and double air-drive pistons (denoted by the -01 or -02 in model number). A double air piston can increase the liquid output pressure or decrease the required air pressure to get the same amount of “work” from the pump. All Autoclave pumps utilize All-Stainless Steel wetted parts with an All-Aluminum air housing.  


Markets:
• Oil and Gas
• Petrochemical
• Chemical
• Research


Features/Benefits:
• Compact, Air Operated Liquid High Pressure Pump
• Air to Liquid Pressure Ratio:  1:11
• Hardened Stainless Steel Plunger
• Air Drive Pressure Range: 15-150 psi (1-10 bar)
• Volume Displacement per Stroke:  5.22 in³ (85.5 cm³)
• Maximum Outlet Pressure:  1,600 psi (110 bar)
• Pre-lubricated at the factory
    

Applications:
• High Flow Test Systems
• Hydrostatic testing of tanks, pressure vessels
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceDivisionMaximum Outlet Pressure RatingMinimum Operating TemperatureShipping WeightLiquid Inlet Port SizePilot Air Inlet Port SizeSupply Air Inlet Port SizeDisplacement per StrokePressure RatingLiquid Outlet Port SizePiston Air DriveSeal TypeLiquid Inlet LocationIsolation ChamberPressure Ratio (Air/Water)
ASL10-02BCPB
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualUHMWPE U-Cup and Buna-N O-RingsBottomIncluded1:22
ASL10-02BCPC
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualUHMWPE U-Cup and Perfluoroelastomer O-RingsBottomIncluded1:22
ASL10-02BCPE
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualUHMWPE U-Cup and EPDM O-RingsBottomIncluded1:22
ASL10-02BCPV
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualUHMWPE U-Cup and Viton O-RingsBottomIncluded1:22
ASL10-02BCTB
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualThermoplastic Polyester U-Cup and Buna-N O-RingsBottomIncluded1:22
ASL10-02BCTC
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualThermoplastic Polyester U-Cup and Perfluoroelastomer O-RingsBottomIncluded1:22
ASL10-02BCTE
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualThermoplastic Polyester U-Cup and EPDM O-RingsBottomIncluded1:22
ASL10-02BCTV
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualThermoplastic Polyester U-Cup and Viton O-RingsBottomIncluded1:22
ASL10-02BCUB
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualUrethane U-Cup and Buna-N O-RingsBottomIncluded1:22
ASL10-02BCUE
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualUrethane U-Cup and EPDM O-RingsBottomIncluded1:22
ASL10-02BCUV
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualUrethane U-Cup and Viton O-RingsBottomIncluded1:22
ASL10-02BNPB
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualUHMWPE U-Cup and Buna-N O-RingsBottomNone1:22
ASL10-02BNPC
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualUHMWPE U-Cup and Perfluoroelastomer O-RingsBottomNone1:22
ASL10-02BNPE
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualUHMWPE U-Cup and EPDM O-RingsBottomNone1:22
ASL10-02BNPV
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualUHMWPE U-Cup and Viton O-RingsBottomNone1:22
ASL10-02BNTB
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualThermoplastic Polyester U-Cup and Buna-N O-RingsBottomNone1:22
ASL10-02BNTC
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualThermoplastic Polyester U-Cup and Perfluoroelastomer O-RingsBottomNone1:22
ASL10-02BNTE
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualThermoplastic Polyester U-Cup and EPDM O-RingsBottomNone1:22
ASL10-02BNTV
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualThermoplastic Polyester U-Cup and Viton O-RingsBottomNone1:22
ASL10-02BNUB
Quote Required
TBD
Instrumentation Products Division3200-18 to 6024.9NPTFNPTFNPTF 1/25.2215 to 150NPTFDualUrethane U-Cup and Buna-N O-RingsBottomNone1:22