*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s D61VL directional control valves are available in 2 or 3-position. They are manifold or subplate mounted valves which conform to NFPA’s D08, CETOP 8 mounting patterns.

Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities

Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceSpool CodeMaximum Operating TemperatureSpool PositionActuation TypeMounting TypeWeightDivisionMaximum Operating PressureValve TypeMaximum Flow RateBody MaterialMinimum Operating TemperatureOptionsSizePilot Inlet / Drain LocationsSeal MaterialMaximum Flow RateMaximum Operating PressureMounting TypeSize
D61VL001D1N89
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Stroke Adjust A and B EndsNFPA D08Internal Pilot / External DrainNitrileUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D1N9
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Stroke Adjust A EndNFPA D08Internal Pilot / External DrainNitrileUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D1V
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4n/aNFPA D08Internal Pilot / External DrainFluorocarbonUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D1V60
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Pilot Choke Meter-inNFPA D08Internal Pilot / External DrainFluorocarbonUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D1V7
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Pilot Choke Meter-outNFPA D08Internal Pilot / External DrainFluorocarbonUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D1V8
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Stroke Adjust B EndNFPA D08Internal Pilot / External DrainFluorocarbonUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D1V89
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Stroke Adjust A and B EndsNFPA D08Internal Pilot / External DrainFluorocarbonUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D1V9
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Stroke Adjust A EndNFPA D08Internal Pilot / External DrainFluorocarbonUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D2N
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4n/aNFPA D08External Pilot / External DrainNitrileUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D2N60
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Pilot Choke Meter-inNFPA D08External Pilot / External DrainNitrileUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D2N7
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Pilot Choke Meter-outNFPA D08External Pilot / External DrainNitrileUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D2N8
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Stroke Adjust B EndNFPA D08External Pilot / External DrainNitrileUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D2N89
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Stroke Adjust A and B EndsNFPA D08External Pilot / External DrainNitrileUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D2N9
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Stroke Adjust A EndNFPA D08External Pilot / External DrainNitrileUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D2V
Quote Required
TBD
3-Position140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4n/aNFPA D08External Pilot / External DrainFluorocarbonUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D2V60
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Pilot Choke Meter-inNFPA D08External Pilot / External DrainFluorocarbonUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D2V7
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Pilot Choke Meter-outNFPA D08External Pilot / External DrainFluorocarbonUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D2V8
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Stroke Adjust B EndNFPA D08External Pilot / External DrainFluorocarbonUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D2V89
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Stroke Adjust A and B EndsNFPA D08External Pilot / External DrainFluorocarbonUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25
D61VL001D2V9
Quote Required
TBD
4-Way140Double OperatorHydraulic PressureSubplate26.7Hydraulic Valve Systems Division3000Lever Operated Directional Control Valve100Gray Iron-4Stroke Adjust A EndNFPA D08External Pilot / External DrainFluorocarbonUp to 100 GPM depending on spool3000 PSISubplateNFPA D08, CETOP 8, DIN NG25