• Availability & Price
  • Search SKU
Filter by attributes
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Mounting Type
  • Size
More Filters...
Filter by manufacturer
Manufacturers

Lever Operated Directional Control Valve - D61VL Series

Picture for category Lever Operated Directional Control Valve - D61VL Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s D61VL directional control valves are available in 2 or 3-position. They are manifold or subplate mounted valves which conform to NFPA’s D08, CETOP 8 mounting patterns.

Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities

Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceSeal MaterialMaximum Operating TemperatureDivisionMaximum Operating PressureMinimum Operating TemperatureActuation TypeMaximum Flow RateMounting TypeSizeBody MaterialOptionsSpool CodeSpool PositionPilot Inlet / Drain LocationsValve TypeWeightMaximum Operating PressureMounting TypeSizeMaximum Flow Rate
D61VL001B5N89
Quote Required
TBD
Nitrile140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronStroke Adjust A and B Ends4-WaySingle OperatorExternal Pilot / Internal DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001B5N9
Quote Required
TBD
Nitrile140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronStroke Adjust A End4-WaySingle OperatorExternal Pilot / Internal DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001B5V
Quote Required
TBD
Fluorocarbon140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray Ironn/a4-WaySingle OperatorExternal Pilot / Internal DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001B5V60
Quote Required
TBD
Fluorocarbon140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronPilot Choke Meter-in4-WaySingle OperatorExternal Pilot / Internal DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001B5V7
Quote Required
TBD
Fluorocarbon140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronPilot Choke Meter-out4-WaySingle OperatorExternal Pilot / Internal DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001B5V8
Quote Required
TBD
Fluorocarbon140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronStroke Adjust B End4-WaySingle OperatorExternal Pilot / Internal DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001B5V89
Quote Required
TBD
Fluorocarbon140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronStroke Adjust A and B Ends4-WaySingle OperatorExternal Pilot / Internal DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001B5V9
Quote Required
TBD
Fluorocarbon140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronStroke Adjust A End4-WaySingle OperatorExternal Pilot / Internal DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001C1N
Quote Required
TBD
Nitrile140 °FHydraulic Valve Systems Division3000 psi-4 °FHydraulic Pressure100 Gal/minSubplateNFPA D08Gray Ironn/a3-Position3-PositionInternal Pilot / External DrainLever Operated Directional Control Valve26.7 lb3000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001C1N60
Quote Required
TBD
Nitrile140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronPilot Choke Meter-in4-WayDouble OperatorInternal Pilot / External DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001C1N7
Quote Required
TBD
Nitrile140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronPilot Choke Meter-out4-WayDouble OperatorInternal Pilot / External DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001C1N8
Quote Required
TBD
Nitrile140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronStroke Adjust B End4-WayDouble OperatorInternal Pilot / External DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001C1N89
Quote Required
TBD
Nitrile140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronStroke Adjust A and B Ends4-WayDouble OperatorInternal Pilot / External DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001C1N9
Quote Required
TBD
Nitrile140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateDIN NG25Gray IronStroke Adjust A End4-WayDouble OperatorInternal Pilot / External DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001C1V
Quote Required
TBD
Fluorocarbon140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray Ironn/a4-WayDouble OperatorInternal Pilot / External DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001C1V60
Quote Required
TBD
Fluorocarbon140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronPilot Choke Meter-in4-WayDouble OperatorInternal Pilot / External DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001C1V7
Quote Required
TBD
Fluorocarbon140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronPilot Choke Meter-out4-WayDouble OperatorInternal Pilot / External DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001C1V8
Quote Required
TBD
Fluorocarbon140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronStroke Adjust B End4-WayDouble OperatorInternal Pilot / External DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001C1V89
Quote Required
TBD
Fluorocarbon140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronStroke Adjust A and B Ends4-WayDouble OperatorInternal Pilot / External DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool
D61VL001C1V9
Quote Required
TBD
Fluorocarbon140Hydraulic Valve Systems Division3000-4Hydraulic Pressure100SubplateNFPA D08Gray IronStroke Adjust A End4-WayDouble OperatorInternal Pilot / External DrainLever Operated Directional Control Valve26.73000 PSISubplateNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spool