- Availability & Price
- Search SKU
Filter by attributes
- Maximum Flow Rate
- Maximum Operating Pressure
- Mounting Type
- Size
Filter by manufacturer
Recently viewed products
Lever Operated Directional Control Valve - D61VL Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s D61VL directional control valves are available in 2 or 3-position. They are manifold or subplate mounted valves which conform to NFPA’s D08, CETOP 8 mounting patterns.
Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life
Applications:
• Suitable for general hydraulic applications
Read More...Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life
Applications:
• Suitable for general hydraulic applications
| Action | Part No. | Availability | Partner Available | Price | Pilot Inlet / Drain Locations | Body Material | Division | Maximum Operating Pressure | Minimum Operating Temperature | Size | Seal Material | Maximum Operating Temperature | Spool Code | Mounting Type | Actuation Type | Options | Weight | Spool Position | Valve Type | Maximum Flow Rate | Maximum Operating Pressure | Maximum Flow Rate | Mounting Type | Size |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| D61VL011K1V9 | Quote Required | TBD | Internal Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Fluorocarbon | 140 | 4-Way | Subplate | Hydraulic Pressure | Stroke Adjust A End | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K1V90 | Quote Required | TBD | Internal Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Fluorocarbon | 140 | 4-Way | Subplate | Hydraulic Pressure | 1/4 BSPP Threads | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2N | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Nitrile | 140 | 4-Way | Subplate | Hydraulic Pressure | n/a | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2N60 | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Nitrile | 140 | 4-Way | Subplate | Hydraulic Pressure | Pilot Choke Meter-in | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2N7 | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Nitrile | 140 | 4-Way | Subplate | Hydraulic Pressure | Pilot Choke Meter-out | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2N8 | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Nitrile | 140 | 4-Way | Subplate | Hydraulic Pressure | Stroke Adjust B End | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2N89 | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Nitrile | 140 | 4-Way | Subplate | Hydraulic Pressure | Stroke Adjust A and B Ends | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2N9 | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Nitrile | 140 | 4-Way | Subplate | Hydraulic Pressure | Stroke Adjust A End | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2N90 | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Nitrile | 140 | 4-Way | Subplate | Hydraulic Pressure | 1/4 BSPP Threads | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2V | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Fluorocarbon | 140 | 4-Way | Subplate | Hydraulic Pressure | n/a | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2V60 | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Fluorocarbon | 140 | 4-Way | Subplate | Hydraulic Pressure | Pilot Choke Meter-in | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2V7 | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Fluorocarbon | 140 | 4-Way | Subplate | Hydraulic Pressure | Pilot Choke Meter-out | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2V8 | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Fluorocarbon | 140 | 4-Way | Subplate | Hydraulic Pressure | Stroke Adjust B End | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2V89 | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Fluorocarbon | 140 | 4-Way | Subplate | Hydraulic Pressure | Stroke Adjust A and B Ends | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2V9 | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Fluorocarbon | 140 | 4-Way | Subplate | Hydraulic Pressure | Stroke Adjust A End | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K2V90 | Quote Required | TBD | External Pilot / External Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Fluorocarbon | 140 | 4-Way | Subplate | Hydraulic Pressure | 1/4 BSPP Threads | 26.7 | Spring Offset to Center | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K4N | Quote Required | TBD | Internal Pilot / Internal Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Nitrile | 140 | 4-Way | Subplate | Hydraulic Pressure | n/a | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K4N60 | Quote Required | TBD | Internal Pilot / Internal Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Nitrile | 140 | 4-Way | Subplate | Hydraulic Pressure | Pilot Choke Meter-in | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K4N7 | Quote Required | TBD | Internal Pilot / Internal Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Nitrile | 140 | 4-Way | Subplate | Hydraulic Pressure | Pilot Choke Meter-out | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL011K4N8 | Quote Required | TBD | Internal Pilot / Internal Drain | Gray Iron | Hydraulic Valve Systems Division | 3000 | -4 | NFPA D08 | Nitrile | 140 | 4-Way | Subplate | Hydraulic Pressure | Stroke Adjust B End | 26.7 | Single Operator | Lever Operated Directional Control Valve | 100 | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 |