Lever Operated Directional Control Valve - D61VL Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s D61VL directional control valves are available in 2 or 3-position. They are manifold or subplate mounted valves which conform to NFPA’s D08, CETOP 8 mounting patterns.
Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life
Applications:
• Suitable for general hydraulic applications
Read More...Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life
Applications:
• Suitable for general hydraulic applications
| Action | Part No. | Availability | Partner Available | Price | Spool Code | Maximum Operating Temperature | Spool Position | Actuation Type | Mounting Type | Weight | Division | Maximum Operating Pressure | Valve Type | Maximum Flow Rate | Body Material | Minimum Operating Temperature | Options | Size | Pilot Inlet / Drain Locations | Seal Material | Maximum Flow Rate | Maximum Operating Pressure | Mounting Type | Size |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| D61VL001D1N89 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Stroke Adjust A and B Ends | NFPA D08 | Internal Pilot / External Drain | Nitrile | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D1N9 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Stroke Adjust A End | NFPA D08 | Internal Pilot / External Drain | Nitrile | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D1V | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | n/a | NFPA D08 | Internal Pilot / External Drain | Fluorocarbon | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D1V60 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Pilot Choke Meter-in | NFPA D08 | Internal Pilot / External Drain | Fluorocarbon | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D1V7 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Pilot Choke Meter-out | NFPA D08 | Internal Pilot / External Drain | Fluorocarbon | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D1V8 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Stroke Adjust B End | NFPA D08 | Internal Pilot / External Drain | Fluorocarbon | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D1V89 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Stroke Adjust A and B Ends | NFPA D08 | Internal Pilot / External Drain | Fluorocarbon | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D1V9 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Stroke Adjust A End | NFPA D08 | Internal Pilot / External Drain | Fluorocarbon | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D2N | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | n/a | NFPA D08 | External Pilot / External Drain | Nitrile | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D2N60 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Pilot Choke Meter-in | NFPA D08 | External Pilot / External Drain | Nitrile | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D2N7 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Pilot Choke Meter-out | NFPA D08 | External Pilot / External Drain | Nitrile | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D2N8 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Stroke Adjust B End | NFPA D08 | External Pilot / External Drain | Nitrile | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D2N89 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Stroke Adjust A and B Ends | NFPA D08 | External Pilot / External Drain | Nitrile | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D2N9 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Stroke Adjust A End | NFPA D08 | External Pilot / External Drain | Nitrile | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D2V | Quote Required | TBD | 3-Position | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | n/a | NFPA D08 | External Pilot / External Drain | Fluorocarbon | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D2V60 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Pilot Choke Meter-in | NFPA D08 | External Pilot / External Drain | Fluorocarbon | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D2V7 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Pilot Choke Meter-out | NFPA D08 | External Pilot / External Drain | Fluorocarbon | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D2V8 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Stroke Adjust B End | NFPA D08 | External Pilot / External Drain | Fluorocarbon | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D2V89 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Stroke Adjust A and B Ends | NFPA D08 | External Pilot / External Drain | Fluorocarbon | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL001D2V9 | Quote Required | TBD | 4-Way | 140 | Double Operator | Hydraulic Pressure | Subplate | 26.7 | Hydraulic Valve Systems Division | 3000 | Lever Operated Directional Control Valve | 100 | Gray Iron | -4 | Stroke Adjust A End | NFPA D08 | External Pilot / External Drain | Fluorocarbon | Up to 100 GPM depending on spool | 3000 PSI | Subplate | NFPA D08, CETOP 8, DIN NG25 |