• Availability & Price
  • Search SKU
Filter by attributes
  • Maximum Flow Rate
  • Maximum Operating Pressure
  • Mounting Type
  • Size
More Filters...
Filter by manufacturer
Manufacturers

Lever Operated Directional Control Valve - D61VL Series

Picture for category Lever Operated Directional Control Valve - D61VL Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s D61VL directional control valves are available in 2 or 3-position. They are manifold or subplate mounted valves which conform to NFPA’s D08, CETOP 8 mounting patterns.

Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities

Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life

Applications:
• Suitable for general hydraulic applications
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceSizeMinimum Operating TemperatureSeal MaterialPilot Inlet / Drain LocationsSpool CodeActuation TypeMaximum Operating TemperatureMounting TypeMaximum Operating PressureBody MaterialDivisionOptionsWeightSpool PositionMaximum Flow RateValve TypeSizeMaximum Flow RateMounting TypeMaximum Operating Pressure
D61VL004E4V7
Quote Required
TBD
NFPA D08-4FluorocarbonInternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionPilot Choke Meter-out26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E4V8
Quote Required
TBD
NFPA D08-4FluorocarbonInternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionStroke Adjust B End26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E4V89
Quote Required
TBD
NFPA D08-4FluorocarbonInternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionStroke Adjust A and B Ends26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E4V9
Quote Required
TBD
NFPA D08-4FluorocarbonInternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionStroke Adjust A End26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E5N
Quote Required
TBD
NFPA D08-4NitrileExternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems Divisionn/a26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E5N60
Quote Required
TBD
NFPA D08-4NitrileExternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionPilot Choke Meter-in26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E5N7
Quote Required
TBD
NFPA D08-4NitrileExternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionPilot Choke Meter-out26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E5N8
Quote Required
TBD
NFPA D08-4NitrileExternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionStroke Adjust B End26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E5N89
Quote Required
TBD
NFPA D08-4NitrileExternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionStroke Adjust A and B Ends26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E5N9
Quote Required
TBD
NFPA D08-4NitrileExternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionStroke Adjust A End26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E5V
Quote Required
TBD
NFPA D08-4FluorocarbonExternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems Divisionn/a26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E5V60
Quote Required
TBD
NFPA D08-4FluorocarbonExternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionPilot Choke Meter-in26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E5V7
Quote Required
TBD
NFPA D08-4FluorocarbonExternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionPilot Choke Meter-out26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E5V8
Quote Required
TBD
NFPA D08-4FluorocarbonExternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionStroke Adjust B End26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E5V89
Quote Required
TBD
NFPA D08-4FluorocarbonExternal Pilot / Internal DrainP Port BlockedHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionStroke Adjust A and B Ends26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004E5V9
Quote Required
TBD
NFPA D08-4FluorocarbonExternal Pilot / Internal Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionStroke Adjust A End26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004H1N
Quote Required
TBD
NFPA D08-4NitrileInternal Pilot / External Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems Divisionn/a26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004H1N60
Quote Required
TBD
NFPA D08-4NitrileInternal Pilot / External Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionPilot Choke Meter-in26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004H1N7
Quote Required
TBD
NFPA D08-4NitrileInternal Pilot / External Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionPilot Choke Meter-out26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI
D61VL004H1N8
Quote Required
TBD
NFPA D08-4NitrileInternal Pilot / External Drain4-WayHydraulic Pressure140Subplate3000Gray IronHydraulic Valve Systems DivisionStroke Adjust B End26.7Single Operator100Lever Operated Directional Control ValveNFPA D08, CETOP 8, DIN NG25Up to 100 GPM depending on spoolSubplate3000 PSI