- Availability & Price
- Search SKU
Filter by attributes
- Maximum Flow Rate
- Maximum Operating Pressure
- Mounting Type
- Size
Filter by manufacturer
Recently viewed products
Lever Operated Directional Control Valve - D61VL Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker’s D61VL directional control valves are available in 2 or 3-position. They are manifold or subplate mounted valves which conform to NFPA’s D08, CETOP 8 mounting patterns.
Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life
Applications:
• Suitable for general hydraulic applications
Read More...Markets:
• Entertainment Automation
• Factory Automation
• Lumber & Wood
• Machine Tools
• Marine
• Material Handling
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Processing
• Molding
• Oil & Gas
• Other Natural Resources
• Packaging Machinery
• Plastic Packaging
• Power Generation
• Primary Metal Refining/Process
• Printing and Marking Equipment
• Rubber & Tire Processing
• Vehicle Assembly Facilities
Features/Benefits:
• Low pressure drop design
• Low force required to shift spool
• Hardened spools provide long life
Applications:
• Suitable for general hydraulic applications
| Action | Part No. | Availability | Partner Available | Price | Pilot Inlet / Drain Locations | Maximum Operating Pressure | Division | Options | Body Material | Valve Type | Maximum Flow Rate | Size | Minimum Operating Temperature | Seal Material | Spool Code | Maximum Operating Temperature | Actuation Type | Spool Position | Weight | Mounting Type | Maximum Operating Pressure | Maximum Flow Rate | Mounting Type | Size |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| D61VL002K5V7 | Quote Required | TBD | External Pilot / Internal Drain | 3000 | Hydraulic Valve Systems Division | Pilot Choke Meter-out | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Fluorocarbon | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL002K5V8 | Quote Required | TBD | External Pilot / Internal Drain | 3000 | Hydraulic Valve Systems Division | Stroke Adjust B End | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Fluorocarbon | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL002K5V89 | Quote Required | TBD | External Pilot / Internal Drain | 3000 | Hydraulic Valve Systems Division | Stroke Adjust A and B Ends | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Fluorocarbon | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL002K5V9 | Quote Required | TBD | External Pilot / Internal Drain | 3000 | Hydraulic Valve Systems Division | Stroke Adjust A End | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Fluorocarbon | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B1N | Quote Required | TBD | Internal Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | n/a | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Nitrile | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B1N60 | Quote Required | TBD | Internal Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Pilot Choke Meter-in | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Nitrile | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B1N7 | Quote Required | TBD | Internal Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Pilot Choke Meter-out | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Nitrile | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B1N8 | Quote Required | TBD | Internal Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Stroke Adjust B End | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Nitrile | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B1N89 | Quote Required | TBD | Internal Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Stroke Adjust A and B Ends | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Nitrile | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B1N9 | Quote Required | TBD | Internal Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Stroke Adjust A End | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Nitrile | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B1V | Quote Required | TBD | Internal Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | n/a | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Fluorocarbon | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B1V60 | Quote Required | TBD | Internal Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Pilot Choke Meter-in | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Fluorocarbon | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B1V7 | Quote Required | TBD | Internal Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Pilot Choke Meter-out | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Fluorocarbon | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B1V8 | Quote Required | TBD | Internal Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Stroke Adjust B End | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Fluorocarbon | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B1V89 | Quote Required | TBD | Internal Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Stroke Adjust A and B Ends | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Fluorocarbon | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B1V9 | Quote Required | TBD | Internal Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Stroke Adjust A End | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Fluorocarbon | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B2N | Quote Required | TBD | External Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | n/a | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Nitrile | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B2N60 | Quote Required | TBD | External Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Pilot Choke Meter-in | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Nitrile | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B2N7 | Quote Required | TBD | External Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Pilot Choke Meter-out | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Nitrile | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 | ||
| D61VL004B2N8 | Quote Required | TBD | External Pilot / External Drain | 3000 | Hydraulic Valve Systems Division | Stroke Adjust B End | Gray Iron | Lever Operated Directional Control Valve | 100 | NFPA D08 | -4 | Nitrile | 4-Way | 140 | Hydraulic Pressure | Single Operator | 26.7 | Subplate | 3000 PSI | Up to 100 GPM depending on spool | Subplate | NFPA D08, CETOP 8, DIN NG25 |