- Availability & Price
- Search SKU
Filter by attributes
- Bypass Valve (bar)
- Bypass Valve Pressure Rating
- Filter Element
- Filter Element Type
- Flow Capacity (l/min)
- Flow Rate
- Height
- Micron Rating
- Options
- Outside Diameter
Filter by manufacturer
In-Tank Mounted Filter - IN-AGB Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The low-cost, high-performance return line IN-AGB filter features Q3 filter media, a bypass construction with low hysteresis, magnetic pre-filtration and a high dirt-holding capacity. The range is capable of handling flow rates from 30 l/min up to 2400 l/min. LEIF® elements are available for flow rates up to 1500 l/min, meeting the most stringent demands for environmentally-friendly filtration and offering protection against poor quality pirate elements.
Features and Benefits
• The filter is integrated into the tank for a compact, low-cost design
• Bypass construction with low hysteresis for improved system protection.
• Magnetic pre-filtration removes ferrous particles, even during bypass conditions for improved fluid cleanliness levels and extended element life and a high dirt-holding capacity.
• Wide range of diffusers including airtight options.
• Flow from inside to out ensuring all captured contamination is retained inside the element and no recontamination of the system during element change out can occur.
• Patented LEIF® elements safeguard filtration quality
Read More...Features and Benefits
• The filter is integrated into the tank for a compact, low-cost design
• Bypass construction with low hysteresis for improved system protection.
• Magnetic pre-filtration removes ferrous particles, even during bypass conditions for improved fluid cleanliness levels and extended element life and a high dirt-holding capacity.
• Wide range of diffusers including airtight options.
• Flow from inside to out ensuring all captured contamination is retained inside the element and no recontamination of the system during element change out can occur.
• Patented LEIF® elements safeguard filtration quality
| Action | Part No. | Availability | Partner Available | Price | Brand | Division | Division | Technology | Product Type | Industry | For Fluid Type | Specifications Met | Operating Temperature | Mounting Type | Indicator Type | Application | Product Series | Operating Pressure | Seal Material | Flow Rate | Micron Rating | Filter Element | Filter Element Type | Bypass Valve Pressure Rating | Options | Height | Outside Diameter | Bypass Valve (bar) | Flow Capacity (l/min) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IN1210CBNEXXX1 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Industrial Manufacturing Equipment | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Articulated Dump Trucks | IN-AGB Series | 0-500 psi | Nitrile | 600 l/min | 10 µm | 10C Cellulose | 10C Cellulose | 1.5 bar | No diffuser | 599 mm | 150 mm | 1,5 * | |||
| IN1210CBNEXXX3 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Off-road Machinery | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Agricultural Machines | IN-AGB Series | 0-500 psi | Nitrile | 600 l/min | 10 µm | 10C Cellulose | 10C Cellulose | 1.5 bar | Diffuser type T | 617 mm | 193 mm | 1,5 * | |||
| IN1210CBNXXXX1 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Filtration | Hydraulic Filter | Off-road Machinery | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Lubrication Systems | IN-AGB Series | 0 to 34 bar | Nitrile | 600 l/min | 10 µm | 10C Cellulose | 10C Cellulose | Blocked | No diffuser | 599 mm | 150 mm | Blocked | |||
| IN1210QBNBXXX1 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Industrial Manufacturing Equipment | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Forestry Equipment | IN-AGB Series | 0 to 34 bar | Nitrile | 600 l/min | 10 µm | 10Q Microglass | 0.8 bar | No diffuser | 599 mm | 150 mm | |||||
| IN1210QBNEXXX1 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Industrial Manufacturing Equipment | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Lubrication Systems | IN-AGB Series | 0-500 psi | Nitrile | 600 l/min | 10 µm | 10Q Microglass * | 10Q Microglass | 1.5 bar | No diffuser | 599 mm | 150 mm | 1,5 * | 500 * | ||
| IN1210QBNEXXX3 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Filtration | Hydraulic Filter | Off-road Machinery | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Agricultural Machines | IN-AGB Series | 0-500 psi | Nitrile | 600 l/min | 10 µm | 10Q Microglass * | 10Q Microglass | 1.5 bar | Diffuser type T | 617 mm | 193 mm | 1,5 * | |||
| IN1210QBNEXXXA | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Filtration | Hydraulic Filter | Off-road Machinery | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Agricultural Machines | IN-AGB Series | 0-500 psi | Nitrile | 600 l/min | 10 µm | 10Q Microglass | 1.5 bar | Diffuser type T and no magnets | 617 mm | 193 mm | |||||
| IN1210QLBNEXXX1 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Industrial Manufacturing Equipment | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Agricultural Machines | IN-AGB Series | 0-500 psi | Nitrile | 600 l/min | 10 µm | 10QL Ecoglass * | 10QL Ecoglass | 1.5 bar | No diffuser | 599 mm | 150 mm | 1,5 * | |||
| IN1210QLBNEXXX3 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Off-road Machinery | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Lubrication Systems | IN-AGB Series | 0 to 34 bar | Nitrile | 600 l/min | 10 µm | 10QL Ecoglass * | 10QL Ecoglass | 1.5 bar | Diffuser type T | 617 mm | 193 mm | 1,5 * | |||
| IN1220QBNEXXX1 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Filtration | Hydraulic Filter | Off-road Machinery | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Lubrication Systems | IN-AGB Series | 0 to 34 bar | Nitrile | 600 l/min | 20 µm | 20Q Microglass * | 20Q Microglass | 1.5 bar | No diffuser | 599 mm | 150 mm | 1,5 * | 500 * | ||
| IN1220QBNEXXX3 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Filtration | Hydraulic Filter | Industrial Manufacturing Equipment | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Agricultural Machines | IN-AGB Series | 0-500 psi | Nitrile | 600 l/min | 20 µm | 20Q Microglass * | 20Q Microglass | 1.5 bar | Diffuser type T | 617 mm | 193 mm | 1,5 * | |||
| IN1220QBNHXXX1 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Industrial Manufacturing Equipment | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Lubrication Systems | IN-AGB Series | 0 to 34 bar | Nitrile | 600 l/min | 20 µm | 20Q Microglass | 2.0 bar | No diffuser | 599 mm | 150 mm | |||||
| IN1220QLBNEXXX1 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Off-road Machinery | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 | Tank Mounted | No indicator | Forestry Equipment | IN-AGB Series | 0 to 34 | Nitrile | 600 l/min | 20 µm | 20QL Ecoglass * | 20QL Ecoglass | 1.5 bar | No diffuser | 599 mm | 150 mm | 1,5 * | |||
| IN1220QLBNEXXX3 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Industrial Manufacturing Equipment | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 | Tank Mounted | No indicator | Articulated Dump Trucks | IN-AGB Series | 0 to 34 | Nitrile | 600 l/min | 20 µm | 20QL Ecoglass * | 20QL Ecoglass | 1.5 bar | Diffuser type T | 617 mm | 193 mm | 1,5 * | |||
| IN1220QLBNHXXX3 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Filtration | Hydraulic Filter | Off-road Machinery | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Forestry Equipment | IN-AGB Series | 0-500 psi | Nitrile | 600 l/min | 20 µm | 20QL Ecoglass * | 20QL Ecoglass | 2.0 bar | Diffuser type T | 617 mm | 193 mm | 2,0 | |||
| IN1220QVNBXXX3 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Industrial Manufacturing Equipment | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -20 to 120 | Tank Mounted | No indicator | Agricultural Machines | IN-AGB Series | 0-500 | Fluorelastomer | 600 l/min | 20 µm | 20Q Microglass * | 20Q Microglass | 0.8 bar | Diffuser type T | 617 mm | 193 mm | 0.8 | |||
| IN12XBNEXXX1 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Filtration | Hydraulic Filter | Off-road Machinery | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 °C | Tank Mounted | No indicator | Agricultural Machines | IN-AGB Series | 0-500 psi | Nitrile | 600 l/min | n/a | No element | 1.5 bar | No diffuser | 599 mm | 150 mm | |||||
| IN1302QLBNEXXX3 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Industrial Manufacturing Equipment | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 | Tank Mounted | No indicator | Agricultural Machines | IN-AGB Series | 0 to 34 | Nitrile | 280 l/min | 2 µm | 02QL Ecoglass | 02QL Ecoglass | 1.5 bar | Diffuser type T | 590 mm | 260mm | 1,5 * | 600 | ||
| IN1305QBNEXXX1 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Industrial Manufacturing Equipment | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 | Tank Mounted | No indicator | Agricultural Machines | IN-AGB Series | 0 to 34 | Nitrile | 650 l/min | 5 µm | 05Q Microglass | 05Q Microglass | 1.5 bar | No diffuser | 543mm | 230 mm | 1,5 * | 600 | ||
| IN1305QLBNEXXX1 | Quote Required | TBD | Parker | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulics | Hydraulic Filter | Industrial Manufacturing Equipment | Hydraulic Oil | Degree of filtration determined by multipass test according to ISO 16889. | -40 to 100 | Tank Mounted | No indicator | Agricultural Machines | IN-AGB Series | 0 to 34 | Nitrile | 650 l/min | 5 µm | 05QL Ecoglass * | 05QL Ecoglass | 1.5 bar | No diffuser | 543mm | 230 mm | 1,5 * | 600 |