*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The low-cost, high-performance return line IN-AGB filter features Q3 filter media, a bypass construction with low hysteresis, magnetic pre-filtration and a high dirt-holding capacity. The range is capable of handling flow rates from 30 l/min up to 2400 l/min. LEIF® elements are available for flow rates up to 1500 l/min, meeting the most stringent demands for environmentally-friendly filtration and offering protection against poor quality pirate elements.

Features and Benefits

• The filter is integrated into the tank for a compact, low-cost design

• Bypass construction with low hysteresis for improved system protection.

• Magnetic pre-filtration removes ferrous particles, even during bypass conditions for improved fluid cleanliness levels and extended element life and a high dirt-holding capacity.

• Wide range of diffusers including airtight options.

• Flow from inside to out ensuring all captured contamination is retained inside the element and no recontamination of the system during element change out can occur.

• Patented LEIF® elements safeguard filtration quality
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandDivisionDivisionTechnologyProduct TypeIndustryFor Fluid TypeSpecifications MetOperating TemperatureMounting TypeIndicator TypeApplicationProduct SeriesOperating PressureSeal MaterialMicron RatingFilter Element TypeBypass Valve Pressure RatingOptionsFlow RateHeightOutside DiameterFilter ElementBypass Valve (bar)Flow Capacity (l/min)
IN720QBNBXXX1
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterIndustrial Manufacturing EquipmentHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100Tank MountedNo indicatorAgricultural MachinesIN-AGB Series0 to 34Nitrile20 µm20Q Microglass0.8 barNo diffuser460 l/min360 mm125 mm20Q Microglass *0.8230
IN720QBNEXXX1
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterOff-road MachineryHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CTank MountedNo indicatorForestry EquipmentIN-AGB Series0-500 psiNitrile20 µm20Q Microglass1.5 barNo diffuser460 l/min360 mm125 mm20Q Microglass *1,5 *230
IN720QLBNBXXX1
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterIndustrial Manufacturing EquipmentHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CTank MountedNo indicatorExcavatorsIN-AGB Series0 to 34 barNitrile20 µm20QL Ecoglass0.8 barNo diffuser460 l/min360 mm125 mm20QL Ecoglass *0.8230
IN720QLBNEXXX1
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterOff-road MachineryHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CTank MountedNo indicatorForestry EquipmentIN-AGB Series0-500 psiNitrile20 µm20QL Ecoglass1.5 barNo diffuser460 l/min360 mm125 mm20QL Ecoglass *1,5 *230
IN802QBNEXXX1
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterIndustrial Manufacturing EquipmentHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100Tank MountedNo indicatorAgricultural MachinesIN-AGB Series0 to 34Nitrile2 µm02Q Microglass1.5 barNo diffuser140 l/min559 mm125 mm02Q Microglass1,5 *300 *
IN805QLBNEXXX1
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterIndustrial Manufacturing EquipmentHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CTank MountedNo indicatorArticulated Dump TrucksIN-AGB Series0-500 psiNitrile5 µm05QL Ecoglass1.5 barNo diffuser520 l/min559 mm125 mm05QL Ecoglass *1,5 *300 *
IN810CBNEXXX1
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterIndustrial Manufacturing EquipmentHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CTank MountedNo indicatorExcavatorsIN-AGB Series0 to 34 barNitrile10 µm10C Cellulose1.5 barNo diffuser520 l/min559 mm125 mm10C Cellulose1,5 *300 *
IN810CBNEXXX3
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterOff-road MachineryHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CTank MountedNo indicatorLubrication SystemsIN-AGB Series0 to 34 barNitrile10 µm10C Cellulose1.5 barDiffuser type T520 l/min568 mm142 mm
IN810QBNEXXX1
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterOff-road MachineryHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CTank MountedNo indicatorAgricultural MachinesIN-AGB Series0-500 psiNitrile10 µm10Q Microglass1.5 barNo diffuser520 l/min559 mm125 mm10Q Microglass *1,5 *300 *
IN810QLBNBXXX1
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterIndustrial Manufacturing EquipmentHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100Tank MountedNo indicatorAgricultural MachinesIN-AGB Series0 to 34Nitrile10 µm10QL Ecoglass0.8 barNo diffuser520 l/min559 mm125 mm10QL Ecoglass *0.8300 *
IN810QLBNEXXX1
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterOff-road MachineryHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CTank MountedNo indicatorForestry EquipmentIN-AGB Series0-500 psiNitrile10 µm10QL Ecoglass1.5 barNo diffuser520 l/min559 mm125 mm10QL Ecoglass *1,5 *300 *
IN810QLBNEXXX3
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic FilterIndustrial Manufacturing EquipmentHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CTank MountedNo indicatorExcavatorsIN-AGB Series0 to 34 barNitrile10 µm10Q Microglass1.5 barDiffuser type T520 l/min568 mm142 mm
IN820QBNEXXX1
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterOff-road MachineryHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CTank MountedNo indicatorArticulated Dump TrucksIN-AGB Series0-500 psiNitrile20 µm20Q Microglass1.5 barNo diffuser520 l/min559 mm125 mm20Q Microglass *1,5 *300 *
IN820QLBNEXXX1
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic FilterIndustrial Manufacturing EquipmentHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CTank MountedNo indicatorArticulated Dump TrucksIN-AGB Series0-500 psiNitrile20 µm20QL Ecoglass1.5 barNo diffuser520 l/min559 mm125 mm20QL Ecoglass *1,5 *300 *