icountLaserCM30 - Portable Particle Monitor

Picture for category icountLaserCM30 - Portable Particle Monitor

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker icountLCM30 is a next generation fluid system particle contamination monitoring offering an under 90 seconds test procedure. Multi-standard ISO, NAS, AS and GOST cleanliness reporting, data entry and integral printing are all featured on this next generation contamination monitor.

Hydraulic fluid cleanliness plays a critical role in the performance and reliability of industrial equipment. Fluids with high levels of contamination and/or solid particulate matter can damage system components, such as pumps, actuators, or servo valves, leading to shorter maintenance intervals, added downtime, and increased costs

The Parker iCount LaserCM portable particle contamination monitor is a user-friendly field diagnostic device that provides service personnel with the capability to quickly and easily assess the cleanliness of the hydraulic fluid or oil in a wide range of applications. The particle monitor can be utilized while machinery is in operation and is equipped with a number of intuitive features to accommodate users’ unique requirements, including ISO/NAS/AS standard cleanliness reporting, data entry, built-in memory storage, and an integral printer.

The iCount LaserCM features microprocessor-controlled optical scanning for accurate contaminant measurement with a calibration range from ISO 0 to ISO 22 with no monitor saturation.  The particles are measured by a photo diode that converts light intensity to a voltage output, which is recorded against time. As the particle moves across the window, the amount of light lost is proportional to the size of the particle. This reduction in voltage is measured and stored in the iCount LaserCM computer in one of six channels according to particle size. Additional sizes are calculated for reference purposes. Readouts are displayed on the hand-held LCD in the accepted ISO/AS and NAS standards ready for hard copy printing or RS232 computer download. The on-board computer allows storage of up to 1000 test results.

The iCount LaserCM’s compact, user-friendly design and ease of use set it apart from other portable particle monitors on the market. Operating the device is as simple as pressing the start button on the handset. The test procedure is automatic and takes less than 90 seconds to complete.

Also available are the Parker iCountPD for inline continuous particle detection, and the iCountOS.

For additional information, consult the iCount LaserCM documentation in the “Related Documents” section.

Features & Benefits

• Special ‘diagnostics’ are incorporated into the icountLaserCM microprocessor control to ensure effective testing.

• Routine contamination monitoring of oil systems with icountLaserCM saves time and saves money.

• Contamination monitoring is now possible during application operation - icountLaserCM saves on production downtime.

• Data entry allows individual equipment test log details to be recorded.

• Data retrieval of test results from memory via hand set display.

• Automatic test cycle logging of up to 99 tests can be selected via hand set display.

• Totally portable, can be used as easily in the field as in the laboratory.

• Automatic calibration reminder.

• Instant, reproducible results achieved with a test cycle in under 90 seconds.

• Auto-testing allows for the conducting of automatic sequencing tests on flushing systems for example.

• Worldwide service and technical support.

• Re-calibration - Annual certification by an approved Parker Service Centre.

NOTE: Part numbers with regional suffixes relating to the appropriate power lead for that region are now obsolete. Part numbers with no suffix contains UK-EU_US power plug. Regions that require an AU regional style plug will need to add a ACC6NA011 - AU Power Lead Plug.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePricePort TypeBrandTechnologyBody MaterialDivisionDivisionProduct TypeSpecifications MetMaximum Fluid TemperatureWidthHeightWeightIndustryOperating TemperatureLengthAccuracyFlow RatePort SizeCycle TimeProduct StyleSensing MethodOperating HumidityElectrical RequirementsIngress Protection RatingMinimum Fluid TemperatureSignal OutputOperating PressureCommunication InterfaceApplicationSeal MaterialOptionsProduct TypeFor Fluid TypeCalibration TypeElectrical Connection
LCM302022US
Quote Required
TBD
MetricParkerFiltrationBrassHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification80 °C206 mm281 mm7.5 kgIndustrial & Chemical Processing+5 to +40 °C291 mm< 7 %< 400 L/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterLaser(%RH) ±5% RH110 to 240 VACIP545 °CDisplayUp to 420 barUSB-B PortAirplanesFluorocarbonStandardCondition MonitorMineral-based Oils and Petroleum-based FuelMTD calibratedUS
LCM302024
Quote Required
TBD
Hydraulic & Industrial Process Filtration Division EMEAFluorocarbonStandardCondition MonitorMineral-based Oils and Petroleum-based FuelMTD calibratedUK-EU-US
LCM302027
Quote Required
TBD
Hydraulic & Industrial Process Filtration Division EMEAFluorocarbonCase mounted pumpCondition MonitorMineral-based Oils and Petroleum-based FuelACFTD calibratedUK-EU-US
LCM302027AU
Quote Required
TBD
MetricParkerFiltrationBrassHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification80 °C206 mm281 mm7.5 kgIndustrial Manufacturing Equipment+5 to +40 °C291 mm< 7 %30 ml/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterLaser(%RH) ±5% RH110 to 240 VACIP5441 °FDisplay36 psiUSB-B PortAirplanesFluorocarbonCase mounted pumpCondition MonitorMineral-based Oils and Petroleum-based FuelACFTD calibratedAustralia
LCM302027EU
Quote Required
TBD
MetricParkerHydraulicsStainless SteelHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification80 °C206 mm281 mm7.5 kgIndustrial Manufacturing Equipment+5 to +40 °C291 mm< 7 %30 L/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterLaser(%RH) ±5% RH110 to 240 VACIP5441 °FDisplay36 psiUSB-B PortExcavatorsFluorocarbonCase mounted pumpCondition MonitorMineral-based Oils and Petroleum-based FuelACFTD calibratedEU
LCM302027UK
Quote Required
TBD
MetricParkerHydraulicsBrassHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification80 °C206 mm281 mm7.5 kgIndustrial & Chemical Processing+5 to +40 °C291 mm< 7 %30 L/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterLaser(%RH) ±5% RH110 to 240 VACIP5441 °FDisplay2.5 barUSB-B PortHydraulic PressesFluorocarbonCase mounted pumpCondition MonitorMineral-based Oils and Petroleum-based FuelACFTD calibratedUK
LCM302027US
Quote Required
TBD
MetricParkerHydraulicsStainless SteelHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification80 °C206 mm281 mm7.5 kgIndustrial & Chemical Processing+41 to +104 °F291 mm< 7 %30 L/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterLaser(%RH) ±5% RH110 to 240 VACIP5441 °FDisplay36 psiUSB-B PortPower PacksFluorocarbonCase mounted pumpCondition MonitorMineral-based Oils and Petroleum-based FuelACFTD calibratedUS
LCM302028
Quote Required
TBD
Hydraulic & Industrial Process Filtration Division EMEAFluorocarbonCase mounted pumpCondition MonitorMineral-based Oils and Petroleum-based FuelMTD calibratedUK-EU-US
LCM302028AU
Quote Required
TBD
MetricParkerFiltrationStainless SteelHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification80 °C206 mm281 mm7.5 kgIndustrial & Chemical Processing+41 to +104 °F291 mm< 7 %30 L/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterLaser(%RH) ±5% RH110 to 240 VACIP545 °CDisplay2.5 barUSB-B PortPower PacksFluorocarbonCase mounted pumpCondition MonitorMineral-based Oils and Petroleum-based FuelMTD calibratedAustralia
LCM302028EU
Quote Required
TBD
MetricParkerFiltrationStainless SteelHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification80 °C206 mm281 mm7.5 kgIndustrial & Chemical Processing+5 to +40 °C291 mm< 7 %30 L/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterLaser(%RH) ±5% RH110 to 240 VACIP545 °CDisplay36 psiUSB-B PortDrilling EquipmentFluorocarbonCase mounted pumpCondition MonitorMineral-based Oils and Petroleum-based FuelMTD calibratedEU
LCM302028UK
Quote Required
TBD
MetricParkerFiltrationBrassHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification80 °C206 mm281 mm7.5 kgIndustrial Manufacturing Equipment+41 to +104 °F291 mm< 7 %30 L/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterLaser(%RH) ±5% RH110 to 240 VACIP545 °CDisplay2.5 barUSB-B PortAirplanesFluorocarbonCase mounted pumpCondition MonitorMineral-based Oils and Petroleum-based FuelMTD calibratedUK
LCM302028US
Quote Required
TBD
MetricParkerFiltrationBrassHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification176 °F206 mm281 mm7.5 kgIndustrial & Chemical Processing+5 to +40 °C291 mm< 7 %30 L/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterLaser(%RH) ±5% RH110 to 240 VACIP545 °CDisplay2.5 barUSB-B PortIndustrial Power UnitsFluorocarbonCase mounted pumpCondition MonitorMineral-based Oils and Petroleum-based FuelMTD calibratedUS
LCM302064
Quote Required
TBD
Hydraulic & Industrial Process Filtration Division EMEAFFKMAggressive Fluid CompatibleCondition MonitorAggressive Phosphate EstersMTD calibratedUK-EU-US
LCM302064EU
Quote Required
TBD
MetricParkerFiltrationStainless SteelHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification80 °C206 mm281 mm7.5 kgIndustrial & Chemical Processing+5 to +40 °C291 mm< 7 %< 400 L/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterLaser(%RH) ±5% RH110 to 240 VACIP545 °CDisplayUp to 6000 psiUSB-B PortWaste BalersFFKMAggressive Fluid CompatibleCondition MonitorAggressive Phosphate EstersMTD calibratedEU
LCM302064UK
Quote Required
TBD
MetricParkerHydraulicsStainless SteelHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification176 °F206 mm281 mm7.5 kgIndustrial & Chemical Processing+41 to +104 °F291 mm< 7 %< 400 L/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterLaser(%RH) ±5% RH110 to 240 VACIP5441 °FDisplayUp to 420 barUSB-B PortIndustrial Power UnitsFFKMAggressive Fluid CompatibleCondition MonitorAggressive Phosphate EstersMTD calibratedUK
LCM302065
Quote Required
TBD
Hydraulic & Industrial Process Filtration Division EMEAFFKMAggressive Fluid CompatibleCondition MonitorAggressive Phosphate EstersACFTD calibratedUK-EU-US
LCM302065EU
Quote Required
TBD
MetricParkerFiltrationStainless SteelHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification80 °C206 mm281 mm7.5 kgIndustrial Manufacturing Equipment+5 to +40 °C291 mm< 7 %< 400 L/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterLaser(%RH) ±5% RH110 to 240 VACIP5441 °FDisplayUp to 6000 psiUSB-B PortDrilling EquipmentFFKMAggressive Fluid CompatibleCondition MonitorAggressive Phosphate EstersACFTD calibratedEU
SPS2021
Quote Required
TBD
MetricParkerHydraulicsAnodised finishHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEACondition MonitorCE Certification176 °F45 mm53 mm0.5 kgIndustrial & Chemical Processing+41 to +104 °F123 mmn/a %N/A L/minM16< 90 seconds in both single and multi-test mode.Particle Detector/CounterPresure Compensated Flow Controln/an/a VACIP5441 °Fn/a29 to 6000 psin/aHarvestersFluorocarbonn/aSingle Point SamplerMineral-based Oils and Petroleum-based Fueln/an/a