*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Development work carried out by the CMC engineers, in conjunction with Exxon Mobil Aviation, highlighted the need for an alternative test method to determine the levels of dispersed contamination in Jet fuel. 5 years of field testing
and development of the already established and successful icountLCM20 Hydraulic Laser Particle Counter saw the introduction of the Parker icountACM20 with enhanced software providing the user with a better understanding
of the contamination present in a sample. As the benchmark particle counter for use in measuring the levels of Contamination in fuels, the icountACM20, as per the UK's Energy Institute Test Method IP564, has now been included in the DEFSTAN 91-91 Issue 6 Jet Fuel Specification as a report only test alongside the current Gravimetric test method (IP423 or ASTM D5452) and Clear & Bright Visual test method
(IP216 or ASTM D2276) Product Features
• Monitors aviation fuel contamination to DEFSTAN 91-91 Issue 6 Jet A-1 fuel specification - IP654
• Multi-standard ISO cleanliness reporting
• Laser optical scanning analysis
• Fully manufactured by Parker with 20 years experience in the Particle Counter measuring market
Specifications
• 2-minute test procedure • Latest averaging software as standard • Downloader software
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePricePort TypeBrandIndustryTechnologyBody MaterialIngress Protection RatingDivisionDivisionSeal MaterialProduct TypeSpecifications MetFor Fluid TypeFlow RateWidthHeightWeightOperating PressureOperating TemperatureMaterials of ConstructionLengthAccuracyPort SizeCycle TimeProduct StyleSensing MethodOperating HumidityATEX Specifications MetCommunication InterfaceElectrical RequirementsMaximum Fluid TemperatureMinimum Fluid TemperatureOptionsCertificatesModel NumberConnection StyleFlow Capacity (l/min)
ACM202022EUR
Quote Required
TBD
MetricParkerOil & GasFiltrationStainless SteelN/AHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFluorocarbonCondition MonitorCE CertificationDiesel380 L/min178 mm277 mm8 kg29 to 6000 psi5 to 40 °CStainless Steel armoured ends178 mm< 7 %M16< 2 minParticle Detector/CounterLasern/an/aUSB Port12VDC input, 6 x 'D' cell batteries, rechargeable battery pack176 °F5 °CEURIP55202022Electrical EU380
ACM202022UK
Quote Required
TBD
MetricParkerOil & GasFiltrationBrassN/AHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFluorocarbonCondition MonitorIP564:2020Diesel380 L/min178 mm277 mm8 kg2 to 420 bar41 to 104 °FStainless Steel armoured ends240 mm< 7 %M16< 2 minParticle Detector/CounterLasern/an/aUSB Port110 to 240 VAC80 °C41 °FUKIP55202022Electrical UK380
ACM202022US
Quote Required
TBD
MetricParkerAerospaceFiltrationBrassN/AHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFluorocarbonCondition MonitorCE CertificationJet Fuel380 L/min178 mm277 mm15 kg29 to 6000 psi41 to 104 °FHousing: Nylon240 mm< 7 %M16< 2 minParticle Detector/CounterLasern/an/aUSB Port12VDC input, 6 x 'D' cell batteries, rechargeable battery pack176 °F41 °FUSIP55202022Electrical US380
ACM202024EUR
Quote Required
TBD
MetricParkerAerospaceFiltrationBrassN/AHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFluorocarbonCondition MonitorIP564:2020Jet Fuel380 L/min178 mm277 mm15 kg2 to 420 bar5 to 40 °CHousing: Nylon240 mm< 7 %M16< 2 minParticle Detector/CounterLasern/an/aUSB Port110 to 240 VAC80 °C41 °FEURIP55202024Electrical EU380
ACM202024UK
Quote Required
TBD
MetricParkerOil & GasFiltrationStainless SteelN/AHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFluorocarbonCondition MonitorCE CertificationJet Fuel380 L/min178 mm277 mm8 kg29 to 6000 psi5 to 40 °CHousing: Nylon240 mm< 7 %M16< 2 minParticle Detector/CounterLasern/an/aUSB Port12VDC input, 6 x 'D' cell batteries, rechargeable battery pack176 °F41 °FUKIP55202024Electrical UK380
ACM202024US
Quote Required
TBD
MetricParkerOil & GasFiltrationBrassN/AHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFluorocarbonCondition MonitorCE CertificationDiesel380 L/min178 mm277 mm8 kg2 to 420 bar41 to 104 °FStainless Steel armoured ends240 mm< 7 %M16< 2 minParticle Detector/CounterLasern/an/aUSB Port12VDC input, 6 x 'D' cell batteries, rechargeable battery pack80 °C41 °FUSIP55202024Electrical UK380
ACM202032
Quote Required
TBD
MetricParkerAerospaceFiltrationBrassN/AHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFluorocarbonCondition MonitorCE CertificationDiesel3801782771529 to 6000up to 80Stainless Steel armoured ends240< 7M16< 2Particle Detector/CounterLasern/an/aUSB Port110 to 240AllATEX Z2202032Electrical All420