- Availability & Price
- Search SKU
Filter by attributes
- Certificates
- Connection Style
- Flow Capacity (l/min)
- Model Number
- Options
Filter by manufacturer
IcountACM - Aviation fuel contamination monitoring
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Development work carried out by the CMC engineers, in conjunction with Exxon Mobil Aviation, highlighted the need for an alternative test method to determine the levels of dispersed contamination in Jet fuel. 5 years of field testing
and development of the already established and successful icountLCM20 Hydraulic Laser Particle Counter saw the introduction of the Parker icountACM20 with enhanced software providing the user with a better understanding
of the contamination present in a sample. As the benchmark particle counter for use in measuring the levels of Contamination in fuels, the icountACM20, as per the UK's Energy Institute Test Method IP564, has now been included in the DEFSTAN 91-91 Issue 6 Jet Fuel Specification as a report only test alongside the current Gravimetric test method (IP423 or ASTM D5452) and Clear & Bright Visual test method
(IP216 or ASTM D2276) Product Features
• Monitors aviation fuel contamination to DEFSTAN 91-91 Issue 6 Jet A-1 fuel specification - IP654
• Multi-standard ISO cleanliness reporting
• Laser optical scanning analysis
• Fully manufactured by Parker with 20 years experience in the Particle Counter measuring market
Specifications
• 2-minute test procedure • Latest averaging software as standard • Downloader software
Read More...and development of the already established and successful icountLCM20 Hydraulic Laser Particle Counter saw the introduction of the Parker icountACM20 with enhanced software providing the user with a better understanding
of the contamination present in a sample. As the benchmark particle counter for use in measuring the levels of Contamination in fuels, the icountACM20, as per the UK's Energy Institute Test Method IP564, has now been included in the DEFSTAN 91-91 Issue 6 Jet Fuel Specification as a report only test alongside the current Gravimetric test method (IP423 or ASTM D5452) and Clear & Bright Visual test method
(IP216 or ASTM D2276) Product Features
• Monitors aviation fuel contamination to DEFSTAN 91-91 Issue 6 Jet A-1 fuel specification - IP654
• Multi-standard ISO cleanliness reporting
• Laser optical scanning analysis
• Fully manufactured by Parker with 20 years experience in the Particle Counter measuring market
Specifications
• 2-minute test procedure • Latest averaging software as standard • Downloader software
| Action | Part No. | Availability | Partner Available | Price | Port Type | Brand | Industry | Technology | Body Material | Ingress Protection Rating | Division | Division | Seal Material | Product Type | Specifications Met | For Fluid Type | Flow Rate | Width | Height | Weight | Operating Pressure | Operating Temperature | Materials of Construction | Length | Accuracy | Port Size | Cycle Time | Product Style | Sensing Method | Operating Humidity | ATEX Specifications Met | Communication Interface | Electrical Requirements | Maximum Fluid Temperature | Minimum Fluid Temperature | Options | Certificates | Model Number | Connection Style | Flow Capacity (l/min) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ACM202022EUR | Quote Required | TBD | Metric | Parker | Oil & Gas | Filtration | Stainless Steel | N/A | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Fluorocarbon | Condition Monitor | CE Certification | Diesel | 380 L/min | 178 mm | 277 mm | 8 kg | 29 to 6000 psi | 5 to 40 °C | Stainless Steel armoured ends | 178 mm | < 7 % | M16 | < 2 min | Particle Detector/Counter | Laser | n/a | n/a | USB Port | 12VDC input, 6 x 'D' cell batteries, rechargeable battery pack | 176 °F | 5 °C | EUR | IP55 | 202022 | Electrical EU | 380 | ||
| ACM202022UK | Quote Required | TBD | Metric | Parker | Oil & Gas | Filtration | Brass | N/A | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Fluorocarbon | Condition Monitor | IP564:2020 | Diesel | 380 L/min | 178 mm | 277 mm | 8 kg | 2 to 420 bar | 41 to 104 °F | Stainless Steel armoured ends | 240 mm | < 7 % | M16 | < 2 min | Particle Detector/Counter | Laser | n/a | n/a | USB Port | 110 to 240 VAC | 80 °C | 41 °F | UK | IP55 | 202022 | Electrical UK | 380 | ||
| ACM202022US | Quote Required | TBD | Metric | Parker | Aerospace | Filtration | Brass | N/A | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Fluorocarbon | Condition Monitor | CE Certification | Jet Fuel | 380 L/min | 178 mm | 277 mm | 15 kg | 29 to 6000 psi | 41 to 104 °F | Housing: Nylon | 240 mm | < 7 % | M16 | < 2 min | Particle Detector/Counter | Laser | n/a | n/a | USB Port | 12VDC input, 6 x 'D' cell batteries, rechargeable battery pack | 176 °F | 41 °F | US | IP55 | 202022 | Electrical US | 380 | ||
| ACM202024EUR | Quote Required | TBD | Metric | Parker | Aerospace | Filtration | Brass | N/A | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Fluorocarbon | Condition Monitor | IP564:2020 | Jet Fuel | 380 L/min | 178 mm | 277 mm | 15 kg | 2 to 420 bar | 5 to 40 °C | Housing: Nylon | 240 mm | < 7 % | M16 | < 2 min | Particle Detector/Counter | Laser | n/a | n/a | USB Port | 110 to 240 VAC | 80 °C | 41 °F | EUR | IP55 | 202024 | Electrical EU | 380 | ||
| ACM202024UK | Quote Required | TBD | Metric | Parker | Oil & Gas | Filtration | Stainless Steel | N/A | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Fluorocarbon | Condition Monitor | CE Certification | Jet Fuel | 380 L/min | 178 mm | 277 mm | 8 kg | 29 to 6000 psi | 5 to 40 °C | Housing: Nylon | 240 mm | < 7 % | M16 | < 2 min | Particle Detector/Counter | Laser | n/a | n/a | USB Port | 12VDC input, 6 x 'D' cell batteries, rechargeable battery pack | 176 °F | 41 °F | UK | IP55 | 202024 | Electrical UK | 380 | ||
| ACM202024US | Quote Required | TBD | Metric | Parker | Oil & Gas | Filtration | Brass | N/A | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Fluorocarbon | Condition Monitor | CE Certification | Diesel | 380 L/min | 178 mm | 277 mm | 8 kg | 2 to 420 bar | 41 to 104 °F | Stainless Steel armoured ends | 240 mm | < 7 % | M16 | < 2 min | Particle Detector/Counter | Laser | n/a | n/a | USB Port | 12VDC input, 6 x 'D' cell batteries, rechargeable battery pack | 80 °C | 41 °F | US | IP55 | 202024 | Electrical UK | 380 | ||
| ACM202032 | Quote Required | TBD | Metric | Parker | Aerospace | Filtration | Brass | N/A | Hydraulic & Industrial Process Filtration Division EMEA | Hydraulic & Industrial Process Filtration Division EMEA | Fluorocarbon | Condition Monitor | CE Certification | Diesel | 380 | 178 | 277 | 15 | 29 to 6000 | up to 80 | Stainless Steel armoured ends | 240 | < 7 | M16 | < 2 | Particle Detector/Counter | Laser | n/a | n/a | USB Port | 110 to 240 | All | ATEX Z2 | 202032 | Electrical All | 420 |