- Availability & Price
- Search SKU
Filter by attributes
- Connection
- Connection Size
- Flow Rate
- Hose I.D. (inch)
- Materials of Construction
- Operating Pressure
- Port Connection
- Tube Bundle Type
- Type
Filter by manufacturer
Hypercool Water Cooled Aftercooler
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Compressed air and gases contain high levels of liquid water vapour. Effective water removal leads to reduced maintenance costs, enhanced system operation and improved product quality. Hypercool water cooled aftercoolers represent the vital first step in this process, installed immediately downstream of compressors or blowers they eliminate over 80% of the water present within compressed air and gas systems.
Controlled compressed air or gas temperature is essential for many industrial applications for efficient operation. The air or gas temperature can be very high at the compressor outlet. Hypercool water cooled aftercoolers can control this. They have been specifically designed to achieve maximum cooling at minimum cost, within a package designed to withstand the rigors of modern industry.
The ribbed tubing design offers high heat exchange efficiency with minimal pressure drops. Hypercool's extensive range of models includes those with fixed and removable aftercoolers, high pressure configurations and versions with special materials for any gas and water quality requirement.
A high quality aftercooler properly sized is an excellent investment that can help ensure that the compressed air or gas system works properly thereby guaranteeing the quality of the finished product.
Features:
• Fixed or removable tube bundles
• Carbon steel shell and copper tubes for standard applications
• Cupro-nickel shell and tubes for sea water use
• Stainless steel shell and tubes for aggressive gas and/or water
• Carbon steel shell and stainless steel tubes for aggressive air or gas
• High pressures up to 40 barg (up to 80 barg on request) and low pressures down to 1barg
• Stainless steel centrifugal water separators are available on request
Benefits:
• Provides significant energy and capital investment savings
• Optimises compressed air system or gas treatment station performance
• Reduces maintenance and improves product quality
• Ensures reliable and continuous operation
• Very low pressure drops with optimum cooling performances
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Controlled compressed air or gas temperature is essential for many industrial applications for efficient operation. The air or gas temperature can be very high at the compressor outlet. Hypercool water cooled aftercoolers can control this. They have been specifically designed to achieve maximum cooling at minimum cost, within a package designed to withstand the rigors of modern industry.
The ribbed tubing design offers high heat exchange efficiency with minimal pressure drops. Hypercool's extensive range of models includes those with fixed and removable aftercoolers, high pressure configurations and versions with special materials for any gas and water quality requirement.
A high quality aftercooler properly sized is an excellent investment that can help ensure that the compressed air or gas system works properly thereby guaranteeing the quality of the finished product.
Features:
• Fixed or removable tube bundles
• Carbon steel shell and copper tubes for standard applications
• Cupro-nickel shell and tubes for sea water use
• Stainless steel shell and tubes for aggressive gas and/or water
• Carbon steel shell and stainless steel tubes for aggressive air or gas
• High pressures up to 40 barg (up to 80 barg on request) and low pressures down to 1barg
• Stainless steel centrifugal water separators are available on request
Benefits:
• Provides significant energy and capital investment savings
• Optimises compressed air system or gas treatment station performance
• Reduces maintenance and improves product quality
• Ensures reliable and continuous operation
• Very low pressure drops with optimum cooling performances
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Weight | Technology | Length | Product Series | Operating Pressure | Micron Rating | Division | Application | Division | Industry | Brand | Product Style | Product Type | Materials of Construction | Port Connection | Tube Bundle Type | Operating Pressure | Flow Rate |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WFN002 | Quote Required | TBD | 2.5 kg | Filtration | 720 mm | Hypercool Water Cooled Aftercooler | 145 to 232 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Pharmaceuticals | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: ¾" - Water: ⅜" | Fixed | Maximum: 16 barg (232 psig) | 72 m³/h @ 7 barg | ||
| WFN004 | Quote Required | TBD | 12 lb | Filtration | 980 mm | Hypercool Water Cooled Aftercooler | 10 to 16 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Automotive | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: 1½" - Water: ½" | Fixed | Maximum: 16 barg (232 psig) | 210 m³/h @ 7 barg | ||
| WFN007 | Quote Required | TBD | 9 kg | Filtration | 1000 mm | Hypercool Water Cooled Aftercooler | 145 to 232 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Food & Beverage | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: 1½" - Water: ¾" | Fixed | Maximum: 16 barg (232 psig) | 390 m³/h @ 7 barg | ||
| WFN009 | Quote Required | TBD | 23 lb | Filtration | 40.1 inch | Hypercool Water Cooled Aftercooler | 10 to 16 barg (max.) | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Electronics | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: 2" - Water: ¾" | Fixed | Maximum: 16 barg (232 psig) | 540 m³/h @ 7 barg | ||
| WFN013 | Quote Required | TBD | 33 lb | Filtration | 1050 mm | Hypercool Water Cooled Aftercooler | 145 to 232 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Pharmaceuticals | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: 2" - Water: ¾" | Fixed | Maximum: 16 barg (232 psig) | 810 m³/h @ 7 barg | ||
| WFN018 | Quote Required | TBD | 13 kg | Filtration | 35.4 inch | Hypercool Water Cooled Aftercooler | 145 to 232 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Food & Beverage | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: DN 80 - Water: 1" | Fixed | Maximum: 12 barg (174 psig) | 1080 m³/h @ 7 barg | ||
| WFN027 | Quote Required | TBD | 18 kg | Filtration | 900 mm | Hypercool Water Cooled Aftercooler | 145 to 232 psig (max.) | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: DN 200 - Water: 1¼" | Fixed | Maximum: 12 barg (174 psig) | 1620 m³/h @ 7 barg | ||
| WFN036 | Quote Required | TBD | 53 lb | Filtration | 35.4 inch | Hypercool Water Cooled Aftercooler | 10 to 16 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Automotive | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: DN 100 - Water: 1¼" | Fixed | Maximum: 12 barg (174 psig) | 2160 m³/h @ 7 barg | ||
| WFN050 | Quote Required | TBD | 156 lb | Filtration | 51.1 inch | Hypercool Water Cooled Aftercooler | 145 to 232 psig (max.) | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Pharmaceuticals | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: DN 125 - Water: 1¼" | Fixed | Maximum: 12 barg (174 psig) | 3000 m³/h @ 7 barg | ||
| WFN060 | Quote Required | TBD | 89 kg | Filtration | 51.1 inch | Hypercool Water Cooled Aftercooler | 10 to 16 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Food & Beverage | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: DN 150 - Water: 1¼" | Fixed | Maximum: 12 barg (174 psig) | 3600 m³/h @ 7 barg | ||
| WFN090 | Quote Required | TBD | 121 kg | Filtration | 1300 mm | Hypercool Water Cooled Aftercooler | 10 to 16 barg (max.) | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Food & Beverage | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: DN 200 - Water: 1¼" | Fixed | Maximum: 12 barg (174 psig) | 5400 m³/h @ 7 barg | ||
| WFP001 | Quote Required | TBD | 15 lb | Filtration | 24.4 inch | Hypercool Water Cooled Aftercooler | 10 to 16 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: ¾" - Water: ½" | Fixed | Maximum: 40 barg (580 psig) | 60 m³/h @ 7 barg | ||
| WFP003 | Quote Required | TBD | 14 kg | Filtration | 1106 mm | Hypercool Water Cooled Aftercooler | 10 to 16 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Automotive | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: 1½" - Water: ½" | Fixed | Maximum: 40 barg (580 psig) | 180 m³/h @ 7 barg | ||
| WFP007 | Quote Required | TBD | 16 kg | Filtration | 51.2 inch | Hypercool Water Cooled Aftercooler | 145 to 232 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Food & Beverage | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: 1½" - Water: ½" | Fixed | Maximum: 40 barg (580 psig) | 420 m³/h @ 7 barg | ||
| WFP011 | Quote Required | TBD | 70 lb | Filtration | 61.5 inch | Hypercool Water Cooled Aftercooler | 10 to 16 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Automotive | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: 2" - Water: ¾" | Fixed | Maximum: 40 barg (580 psig) | 660 m³/h @ 7 barg | ||
| WFP016 | Quote Required | TBD | 77 lb | Filtration | 1300 mm | Hypercool Water Cooled Aftercooler | 145 to 232 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: DN 80 - Water: ¾" | Fixed | Maximum: 40 barg (580 psig) | 960 m³/h @ 7 barg | ||
| WFP022 | Quote Required | TBD | 110 lb | Filtration | 51.1 inch | Hypercool Water Cooled Aftercooler | 145 to 232 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Food & Beverage | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: DN 100 - Water: 1" | Fixed | Maximum: 40 barg (580 psig) | 1320 m³/h @ 7 barg | ||
| WFP028 | Quote Required | TBD | 54 | Filtration | 1300 | Hypercool Water Cooled Aftercooler | 10 to 16 barg (max.) | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Industrial Manufacturing Equipment | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: DN 100 - Water: 1" | Fixed | Maximum: 40 barg (580 psig) | 1680 m³/h @ 7 barg | ||
| WFP038 | Quote Required | TBD | 152 lb | Filtration | 51.1 inch | Hypercool Water Cooled Aftercooler | 145 to 232 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Pharmaceuticals | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: DN 125 - Water: 1¼" | Fixed | Maximum: 40 barg (580 psig) | 2280 m³/h @ 7 barg | ||
| WFP050 | Quote Required | TBD | 71 kg | Filtration | 51.1 inch | Hypercool Water Cooled Aftercooler | 10 to 16 | Not Applicable | Gas Separation and Filtration Division EMEA | Compressed Air | Gas Separation and Filtration Division EMEA | Automotive | Parker | Water Cooled | Aftercooler | Steel Shell / Copper Tubes | Air: DN 125 - Water: 1¼" | Fixed | Maximum: 40 barg (580 psig) | 3000 m³/h @ 7 barg |