Hypercool BioEnergy Water Cooled Aftercoolers
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The performance of biogas as a fuel depends on effective dehumidification. Saturated raw biogas contains water and impurities that need to be removed to avoid damage to engine equipment and pipelines and to reduce contamination of engine oil, increasing the efficiency of the whole plant and significantly reducing maintenance costs and plant downtime.
For biogas as a fuel, most of the impurities have to be removed, as they may cause corrosion, deposits and damage to equipment. In particular biogas needs to be dried by cooling it to temperatures close to 5°C using water cooled heat exchangers working with water chillers. Hypercool Bioenergy aftercoolers are a key component of this biogas treatment process.
Hypercool Bioenergy aftercoolers provide safe and reliable operation in the harsh environments typically found in Anaerobic Digester and Landfill biogas production areas thanks to the use of stainless steel components specifically treated to maximize corrosion resistance.
Features:
• Shell and tube heat exchanger with smooth pipes
• Material: Parts in contact with biogas in AISI304 or AISI316L, parts not in contact with biogas in AISI304
• Pickling and passivation treatment maximize corrosion resistance production
• Flow rates and performances aligned with CHP power range
• Suitable for horizontal & vertical installations
• Max working pressure: 0.5 bar g
Benefits:
• Highly reliable and continuous operation even in the harshest conditions typically experienced in a biogas plant or a landfill site
• Significant cost savings in investment, management and operation of the system
• High efficiency heat exchange and separation whilst maintaining a very low pressure drop
• Performances and flow rates aligned with CHP and power generation market
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...For biogas as a fuel, most of the impurities have to be removed, as they may cause corrosion, deposits and damage to equipment. In particular biogas needs to be dried by cooling it to temperatures close to 5°C using water cooled heat exchangers working with water chillers. Hypercool Bioenergy aftercoolers are a key component of this biogas treatment process.
Hypercool Bioenergy aftercoolers provide safe and reliable operation in the harsh environments typically found in Anaerobic Digester and Landfill biogas production areas thanks to the use of stainless steel components specifically treated to maximize corrosion resistance.
Features:
• Shell and tube heat exchanger with smooth pipes
• Material: Parts in contact with biogas in AISI304 or AISI316L, parts not in contact with biogas in AISI304
• Pickling and passivation treatment maximize corrosion resistance production
• Flow rates and performances aligned with CHP power range
• Suitable for horizontal & vertical installations
• Max working pressure: 0.5 bar g
Benefits:
• Highly reliable and continuous operation even in the harshest conditions typically experienced in a biogas plant or a landfill site
• Significant cost savings in investment, management and operation of the system
• High efficiency heat exchange and separation whilst maintaining a very low pressure drop
• Performances and flow rates aligned with CHP and power generation market
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Operating Pressure | Product Style | Division | Industry | Application | Technology | Product Series | Weight | Micron Rating | Brand | Division | Length | Product Type | Flow Rate | Materials of Construction | Port Connection |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| WFB240-304 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | 106 lb | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | 1990 mm | Aftercooler | 240 m³/h @ 1 bara | Stainless Steel AISI 304 | Gas: DN125 - Water: 1" | ||
| WFB240-316 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | 106 lb | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | 1990 mm | Aftercooler | 240 m³/h @ 1 bara | Stainless Steel AISI 316 | Gas: DN125 - Water: 1" | ||
| WFB240CSB265A-304 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | Request Information | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | Request Information | Aftercooler & Water Separator Package | 240 m³/h @ 1 bara | Stainless Steel AISI 304 | Gas: DN125 - Water: 1" | ||
| WFB240CSB265A-316 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | Request Information | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | Request Information | Aftercooler & Water Separator Package | 240 m³/h @ 1 bara | Stainless Steel AISI 316 | Gas: DN125 - Water: 1" | ||
| WFB265-304 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | 38 kg | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | 57 inch | Aftercooler | 265 m³/h @ 1 bara | Stainless Steel AISI 304 | Gas: DN125 - Water: 1" | ||
| WFB265-316 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | 84 lb | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | 1490 mm | Aftercooler | 265 m³/h @ 1 bara | Stainless Steel AISI 316 | Gas: DN125 - Water: 1" | ||
| WFB265CSB265A-304 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | Request Information | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | Request Information | Aftercooler & Water Separator Package | 265 m³/h @ 1 bara | Stainless Steel AISI 304 | Gas: DN125 - Water: 1" | ||
| WFB265CSB265A-316 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | Request Information | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | Request Information | Aftercooler & Water Separator Package | 265 m³/h @ 1 bara | Stainless Steel AISI 316 | Gas: DN125 - Water: 1" | ||
| WFB3180-304 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | 490 kg | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | 78.5 inch | Aftercooler | 3180 m³/h @ 1 bara | Stainless Steel AISI 304 | Gas: DN450 - Water: 2½" | ||
| WFB3180-316 | Quote Required | TBD | 0.5 barg (max.) | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | 490 | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | 1990 | Aftercooler | 3180 m³/h @ 1 bara | Stainless Steel AISI 316 | Gas: DN450 - Water: 2½" | ||
| WFB3180CSB3180A-304 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | Request Information | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | Request Information | Aftercooler & Water Separator Package | 3180 m³/h @ 1 bara | Stainless Steel AISI 304 | Gas: DN450 - Water: 2½" | ||
| WFB3180CSB3180A-316 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | Request Information | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | Request Information | Aftercooler & Water Separator Package | 3180 m³/h @ 1 bara | Stainless Steel AISI 316 | Gas: DN450 - Water: 2½" | ||
| WFB360-304 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | 187 lb | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | 1990 mm | Aftercooler | 360 m³/h @ 1 bara | Stainless Steel AISI 304 | Gas: DN200 - Water: 1¼" | ||
| WFB360-316 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | 85 kg | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | 78.5 inch | Aftercooler | 360 m³/h @ 1 bara | Stainless Steel AISI 316 | Gas: DN200 - Water: 1¼" | ||
| WFB360CSB720A-304 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | Request Information | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | Request Information | Aftercooler & Water Separator Package | 360 m³/h @ 1 bara | Stainless Steel AISI 304 | Gas: DN200 - Water: 1¼" | ||
| WFB360CSB720A-316 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | Request Information | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | Request Information | Aftercooler & Water Separator Package | 360 m³/h @ 1 bara | Stainless Steel AISI 316 | Gas: DN200 - Water: 1¼" | ||
| WFB510-304 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | 224 lb | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | 1990 mm | Aftercooler | 510 m³/h @ 1 bara | Stainless Steel AISI 304 | Gas: DN200 - Water: 1¼" | ||
| WFB510-316 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | 224 lb | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | 1990 mm | Aftercooler | 510 m³/h @ 1 bara | Stainless Steel AISI 316 | Gas: DN200 - Water: 1¼" | ||
| WFB510CSB720A-304 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | Request Information | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | Request Information | Aftercooler & Water Separator Package | 510 m³/h @ 1 bara | Stainless Steel AISI 304 | Gas: DN200 - Water: 1¼" | ||
| WFB510CSB720A-316 | Quote Required | TBD | 0.5 | Water Cooled | Gas Separation and Filtration Division EMEA | Renewable Energy | Biogas Applications | Filtration | Hypercool BioEnergy Water Cooled Aftercoolers | Request Information | Not Applicable | Parker | Gas Separation and Filtration Division EMEA | Request Information | Aftercooler & Water Separator Package | 510 m³/h @ 1 bara | Stainless Steel AISI 316 | Gas: DN200 - Water: 1¼" |