High Pressure Inline Hydraulic Oil Filter – iProtect® EPF Series

Picture for category High Pressure Inline Hydraulic Oil Filter – iProtect® EPF Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker EPF Series is a high pressure, inline hydraulic oil filter that provides high-efficiency filtration for equipment in demanding environments, including mining, construction, marine, drilling, and agricultural applications. A unique feature of the EPF Series is that the filter element remains inside the filter bowl when performing a change-out. This can save over 500 mm of space envelope in comparison with traditional high pressure filters on the market. The filter element core is also reusable, which reduces waste by up to 50% when compared to conventional filters with non-reusable elements.

EPF Series filters serve as a highly economical filtration solution in high pressure range applications (up to 450 bar), where compact envelopes and excellent fatigue pressure ratings are critical. Specific examples include (but are not limited to) mobile working hydraulics, wind turbines, drive systems, pilot line filtration systems, servo controls, industrial working hydraulics, control systems, and reverse flow valve applications.

The patented design of the filter element allows for integration of the bypass valve and element core as re-usable parts in the filter bowl. This makes the filter secure and eliminates the risk of forgetting to re-install reusable parts during maintenance. Bypass settings are available up to 7 bar (100 psi) or no bypass versions when using patented, high strength filter elements. The principle is based on differential pressure measurement across the filter element.

The EPF Series is designed for use with EPF Series Replacement Elements and is available with various port connection types, filtration media (2, 5, 10, and 20 micron), indicators, and flow capacities (up to 700 L/min) to meet the unique requirements of customers’ hydraulic circuits

Features and Benefits:
• Prevents damaging of hydraulic circuits or machinery done by dirt, sand, dust, metal, etc.

• Lengthens time in between required maintenance intervals, reduces operating costs, and extends overall equipment/machine operational life

• Compact filter design can save over 500 mm of space envelope when compared to traditional inline hydraulic filters

• Reusable element core with patented filtration technology reduces waste by up to 50% when compared to conventional filters with non-reusable elements

• A "clever" design minimizes the likelihood of installation mistakes

• Can be equipped with an optional reverse flow. This valve assembly is integrated in the element end cap and isolates the filter medium during reverse flow conditions.

• Protected aftermarket to guarantee the use of genuine products to protect equipment/machinery.

• Provides OEM branding (labelling)opportunities

• High efficiency Quantµmfiber™ glass media increases particle capture and dirt holding capacity.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandDivisionDivisionTechnologyFor Fluid TypeSpecifications MetIndicator Pressure SettingIndustryProduct TypeApplicationProduct SeriesProduct StyleOperating PressureMaterials of ConstructionSeal MaterialIndicator TypeMicron RatingOptionsBypass Valve Pressure RatingConnection TypeFlow RateFilter ElementBypass Valve (bar)Filter Element TypePort Connection TypeFlow Capacity (l/min)Mounting TypeOperating Temperature
EPF2202QIBT1MG121
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barMarineHydraulic Oil FiltersHydraulic PressesiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileElectrical NO/NC2 µmStandard, incl. Bypass7.0 bar0 to 110 l/min02QI (Microglass)7.002QI (Microglass)G3/40 to 110
EPF2202QIHBF1MG122
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barOil and GasHydraulic Oil FiltersPower PacksiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileElectronic 4 LED, PNP, N.O.2 µmNo bypassNo Bypass with 5.0 bar indicator0 to 100 l/min02QIH (High Strenght Microglass)No Bypass with 5.0 bar indicator02QIH (High Strength Microglass)G3/40 to 100Inline-40 to 100 °C
EPF2202QIHBM3MG122
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barMiningHydraulic Oil FiltersMarine Steering UnitsiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileVisual2 µmNo bypassNo Bypass with 5.0 bar indicator0 to 100 l/min02QIH (High Strenght Microglass)No Bypass with 5.0 bar indicator02QIH (High Strength Microglass)G3/40 to 100
EPF2202QIHBPXG082
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorAgricultureHydraulic Oil FiltersPower PacksiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrilePlugged with steel plug2 µmNo bypassNo Bypass / No indicator0 to 100 l/min02QIH (High Strenght Microglass)No bypass / No indicator02QIH (High Strength Microglass)G1/20 to 100Inline-40 to 100 °C
EPF2202QIHBPXG122
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorAgricultureHydraulic Oil FiltersHydraulic PressesiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrilePlugged with steel plug2 µmNo bypassNo Bypass / No indicator0 to 100 l/min02QIH (High Strenght Microglass)No bypass / No indicator02QIH (High Strength Microglass)G3/40 to 100
EPF2202QIHBPXX122
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorConstructionHydraulic Oil FiltersExcavatorsiProtect® EPFInline Filter6500 psiHousing: Iron/SteelNitrilePlugged with steel plug2 µmNo bypassNo Bypass / No indicatorManifold Ø22,23 mm (⅞")0 to 100 l/min02QIH (High Strenght Microglass)No bypass / No indicator02QIH (High Strength Microglass)Manifold Ø22,23 mm (7/8")0 to 100Manifold side mounting-40 to 100 °C
EPF2202QIHBT1MG122
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barOil and GasHydraulic Oil FiltersWind turbinesiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileElectrical NO/NC2 µmNo bypassNo Bypass with 5.0 bar indicator0 to 100 l/min02QIH (High Strenght Microglass)No Bypass with 5.0 bar indicator02QIH (High Strength Microglass)G3/40 to 100
EPF2202QIHBT1MH122
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barMarineHydraulic Oil FiltersReach StackersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileElectrical NO/NC2 µmNo bypassNo Bypass with 5.0 bar indicator¾" SAE-6000M0 to 100 l/min02QIH (High Strenght Microglass)No Bypass with 5.0 bar indicator02QIH (High Strength Microglass)3/4" SAE-6000M0 to 100
EPF2202QIHBT1MX122
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barConstructionHydraulic Oil FiltersHydraulic PressesiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileElectrical NO/NC2 µmNo bypassNo Bypass with 5.0 bar indicatorManifold Ø22,23 mm (⅞")0 to 100 l/min02QIH (High Strenght Microglass)No Bypass with 5.0 bar indicator02QIH (High Strength Microglass)Manifold Ø22,23 mm (7/8")0 to 100Manifold side mounting-40 to 100 °C
EPF2202QIRVM3KH12RFV
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.2.5 barMiningHydraulic Oil FiltersMarine Steering UnitsiProtect® EPFInline Filter450 barHousing: Iron/SteelFluorelastomerVisual2 µmReverse flow valve incl. Bypass3.5 bar¾" SAE-6000M0 to 100 l/min02QIR (Microglass - Reverse Flow)3.502QIR (Microglass - Reverse Flow)3/4" SAE-6000M0 to 100
EPF2205QIBF1MG121
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barMaterial HandlingHydraulic Oil FiltersHarvestersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileElectronic 4 LED, PNP, N.O.5 µmStandard, incl. Bypass7.0 bar0 to 120 l/min05QI (Microglass)7.005QI (Microglass)G3/40 to 120
EPF2205QIBF3MG121
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barMaterial HandlingHydraulic Oil FiltersMarine Steering UnitsiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileElectronic 4 LED, PNP, N.C.5 µmStandard, incl. Bypass7.0 bar0 to 120 l/min05QI (Microglass)7.005QI (Microglass)G3/40 to 120Inline-40 to 100 °C
EPF2205QIBF3MX121
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barConstructionHydraulic Oil FiltersHydraulic PressesiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileElectronic 4 LED, PNP, N.C.5 µmStandard, incl. Bypass7.0 barManifold Ø22,23 mm (⅞")0 to 120 l/min05QI (Microglass)7.005QI (Microglass)Manifold Ø22,23 mm (7/8")0 to 120
EPF2205QIBM3KH121
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.2.5 barMaterial HandlingHydraulic Oil FiltersDeck and Mobile CranesiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileVisual5 µmStandard, incl. Bypass3.5 bar¾" SAE-6000M0 to 120 l/min05QI (Microglass)3.505QI (Microglass)3/4" SAE-6000M0 to 120Inline-40 to 100 °C
EPF2205QIBM3LX121
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.3.5 barAgricultureHydraulic Oil FiltersPower PacksiProtect® EPFInline Filter6500 psiHousing: Iron/SteelNitrileVisual5 µmStandard, incl. Bypass5.0 barManifold Ø22,23 mm (⅞")0 to 120 l/min05QI (Microglass)5.005QI (Microglass)Manifold Ø22,23 mm (7/8")0 to 120Manifold side mounting-40 to 100 °C
EPF2205QIBM3MG081
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barMaterial HandlingHydraulic Oil FiltersIndustrial Power UnitsiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileVisual5 µmStandard, incl. Bypass7.0 bar0 to 120 l/min05QI (Microglass)7.005QI (Microglass)G1/20 to 120Inline-40 to 100 °C
EPF2205QIBM3MG121
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barAgricultureHydraulic Oil FiltersDrilling EquipmentiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileVisual5 µmStandard, incl. Bypass7.0 bar0 to 120 l/min05QI (Microglass)7.005QI (Microglass)G3/40 to 120
EPF2205QIBM3MX121
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.5 barMarineHydraulic Oil FiltersHydraulic PressesiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrileVisual5 µmStandard, incl. Bypass7.0 barManifold Ø22,23 mm (⅞")0 to 120 l/min05QI (Microglass)7.005QI (Microglass)Manifold Ø22,23 mm (7/8")0 to 120
EPF2205QIBPKG121
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorAgricultureHydraulic Oil FiltersReach StackersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrilePlugged with steel plug5 µmStandard, incl. Bypass3.5 bar0 to 120 l/min05QI (Microglass)3.505QI (Microglass)G3/40 to 120
EPF2205QIBPMG121
Quote Required
TBD
ParkerHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.No IndicatorOil and GasHydraulic Oil FiltersMarine Steering UnitsiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrilePlugged with steel plug5 µmStandard, incl. Bypass7.0 bar0 to 120 l/min05QI (Microglass)7.005QI (Microglass)G3/40 to 120