• Availability & Price
  • Search SKU
Filter by attributes
  • Bypass Valve (bar)
  • Bypass Valve Pressure Rating
  • Connection Type
  • Filter Element
  • Filter Element Type
  • Flow Capacity (l/min)
  • Flow Rate
  • Indicator Type
  • Micron Rating
  • Options
More Filters...
Filter by manufacturer
Manufacturers

High Pressure Inline Hydraulic Oil Filter – iProtect® EPF Series

Picture for category High Pressure Inline Hydraulic Oil Filter – iProtect® EPF Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The Parker EPF Series is a high pressure, inline hydraulic oil filter that provides high-efficiency filtration for equipment in demanding environments, including mining, construction, marine, drilling, and agricultural applications. A unique feature of the EPF Series is that the filter element remains inside the filter bowl when performing a change-out. This can save over 500 mm of space envelope in comparison with traditional high pressure filters on the market. The filter element core is also reusable, which reduces waste by up to 50% when compared to conventional filters with non-reusable elements.

EPF Series filters serve as a highly economical filtration solution in high pressure range applications (up to 450 bar), where compact envelopes and excellent fatigue pressure ratings are critical. Specific examples include (but are not limited to) mobile working hydraulics, wind turbines, drive systems, pilot line filtration systems, servo controls, industrial working hydraulics, control systems, and reverse flow valve applications.

The patented design of the filter element allows for integration of the bypass valve and element core as re-usable parts in the filter bowl. This makes the filter secure and eliminates the risk of forgetting to re-install reusable parts during maintenance. Bypass settings are available up to 7 bar (100 psi) or no bypass versions when using patented, high strength filter elements. The principle is based on differential pressure measurement across the filter element.

The EPF Series is designed for use with EPF Series Replacement Elements and is available with various port connection types, filtration media (2, 5, 10, and 20 micron), indicators, and flow capacities (up to 700 L/min) to meet the unique requirements of customers’ hydraulic circuits

Features and Benefits:
• Prevents damaging of hydraulic circuits or machinery done by dirt, sand, dust, metal, etc.

• Lengthens time in between required maintenance intervals, reduces operating costs, and extends overall equipment/machine operational life

• Compact filter design can save over 500 mm of space envelope when compared to traditional inline hydraulic filters

• Reusable element core with patented filtration technology reduces waste by up to 50% when compared to conventional filters with non-reusable elements

• A "clever" design minimizes the likelihood of installation mistakes

• Can be equipped with an optional reverse flow. This valve assembly is integrated in the element end cap and isolates the filter medium during reverse flow conditions.

• Protected aftermarket to guarantee the use of genuine products to protect equipment/machinery.

• Provides OEM branding (labelling)opportunities

• High efficiency Quantµmfiber™ glass media increases particle capture and dirt holding capacity.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandMounting TypeIndustryDivisionDivisionTechnologyFor Fluid TypeSpecifications MetOperating TemperatureProduct TypeIndicator Pressure SettingApplicationProduct SeriesProduct StyleOperating PressureMaterials of ConstructionSeal MaterialMicron RatingOptionsIndicator TypeBypass Valve Pressure RatingConnection TypeFlow RateFilter ElementBypass Valve (bar)Filter Element TypeFlow Capacity (l/min)Port Connection Type
EPF4120QIBPMR201
Quote Required
TBD
ParkerInlineConstructionHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CHydraulic Oil FiltersNo IndicatorExcavatorsiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile20 µmStandard, incl. BypassPlugged with steel plug7.0 bar1¼" SAE-3000M0 to 430 l/min20QI (Microglass)7.020QI (Microglass)0 to 4301-1/4" SAE-3000M
EPF4120QIBT1MG201
Quote Required
TBD
ParkerMarineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil Filters5 barWind turbinesiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile20 µmStandard, incl. BypassElectrical NO/NC7.0 barG1¼0 to 430 l/min20QI (Microglass)7.020QI (Microglass)0 to 430G1-1/4
EPF4120QIBT1MG241
Quote Required
TBD
ParkerMaterial HandlingHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil Filters5 barPower PacksiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile20 µmStandard, incl. BypassElectrical NO/NC7.0 barG1½0 to 430 l/min20QI (Microglass)7.020QI (Microglass)0 to 430G1-1/2
EPF4120QIBT1MH201
Quote Required
TBD
ParkerMarineHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil Filters5 barDeck and Mobile CranesiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile20 µmStandard, incl. BypassElectrical NO/NC7.0 bar1¼" SAE-6000M0 to 430 l/min20QI (Microglass)7.020QI (Microglass)0 to 4301-1/4" SAE-6000M
EPF4120QIBXMKIT1
Quote Required
TBD
ParkerManifold integratedConstructionHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CHydraulic Oil FiltersNo IndicatorReach StackersiProtect® EPFInline Filter6500 psiHousing: Iron/SteelNitrile20 µmBowl + Element kit, incl. BypassNo indicator7.0 barNo filter head0 to 430 l/min20QI (Microglass)7.020QI (Microglass)0 to 430No filter head
EPF4120QIHBF3MG242
Quote Required
TBD
ParkerMaterial HandlingHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil Filters5 barForwardersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile20 µmNo bypassElectronic 4 LED, PNP, N.C.No Bypass with 5.0 bar indicatorG1½0 to 400 l/min20QIH (High Strenght Microglass)No Bypass with 5.0 bar indicator20QIH (High Strength Microglass)0 to 400G1-1/2
EPF4120QIHBM3MG202
Quote Required
TBD
ParkerConstructionHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil Filters5 barReach StackersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile20 µmNo bypassVisualNo Bypass with 5.0 bar indicatorG1¼0 to 400 l/min20QIH (High Strenght Microglass)No Bypass with 5.0 bar indicator20QIH (High Strength Microglass)0 to 400G1-1/4
EPF4120QIHBPXG202
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil FiltersNo IndicatorDeck and Mobile CranesiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile20 µmNo bypassPlugged with steel plugNo Bypass / No indicatorG1¼0 to 400 l/min20QIH (High Strenght Microglass)No bypass / No indicator20QIH (High Strength Microglass)0 to 400G1-1/4
EPF4120QIHBT1MG202
Quote Required
TBD
ParkerMaterial HandlingHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil Filters5 barMarine Steering UnitsiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile20 µmNo bypassElectrical NO/NCNo Bypass with 5.0 bar indicatorG1¼0 to 400 l/min20QIH (High Strenght Microglass)No Bypass with 5.0 bar indicator20QIH (High Strength Microglass)0 to 400G1-1/4
EPF4120QIHBT1MG242
Quote Required
TBD
ParkerMaterial HandlingHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil Filters5 barHydraulic PressesiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile20 µmNo bypassElectrical NO/NCNo Bypass with 5.0 bar indicatorG1½0 to 400 l/min20QIH (High Strenght Microglass)No Bypass with 5.0 bar indicator20QIH (High Strength Microglass)0 to 400G1-1/2
EPF4120QIRBM3KG20RFV
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil Filters2.5Deck and Mobile CranesiProtect® EPFInline FilterUp to 420Housing: Iron/SteelNitrile20 µmReverse flow valve incl. BypassVisual3.5 barG1¼0 to 400 l/min20QIR (Microglass - Reverse Flow)3.520QIR (Microglass - Reverse Flow)0 to 400G1-1/4
EPF4120QIRBM3KH20RFV
Quote Required
TBD
ParkerInlineConstructionHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CHydraulic Oil Filters2.5 barPower PacksiProtect® EPFInline Filter6500 psiHousing: Iron/SteelNitrile20 µmReverse flow valve incl. BypassVisual3.5 bar1¼" SAE-6000M0 to 400 l/min20QIR (Microglass - Reverse Flow)3.520QIR (Microglass - Reverse Flow)0 to 4001-1/4" SAE-6000M
EPF4120QIRBPKG20RFV
Quote Required
TBD
ParkerMaterial HandlingHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil FiltersNo IndicatorHarvestersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile20 µmReverse flow valve incl. BypassPlugged with steel plug3.5 barG1¼0 to 400 l/min20QIR (Microglass - Reverse Flow)3.520QIR (Microglass - Reverse Flow)0 to 400G1-1/4
EPF4120QIVT1MG201
Quote Required
TBD
ParkerAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil Filters5Deck and Mobile CranesiProtect® EPFInline FilterUp to 420Housing: Iron/SteelFluorelastomer20 µmStandard, incl. BypassElectrical NO/NC7.0 barG1¼0 to 430 l/min20QI (Microglass)7.020QI (Microglass)0 to 430G1-1/4
EPF41XXXXBPMG201
Quote Required
TBD
ParkerInlineMaterial HandlingHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CHydraulic Oil FiltersNo IndicatorExcavatorsiProtect® EPFInline Filter6500 psiHousing: Iron/SteelNitrileStandard, incl. BypassPlugged with steel plug7.0 barG1¼0 to 430 l/minNo element7.0No element0 to 430G1-1/4
EPF4202QIBF1MG201
Quote Required
TBD
Hydraulic & Industrial Process Filtration Division EMEANitrile2 µmStandard, incl. BypassElectronic 4 LED, PNP, N.O.7.0 barG1¼0 to 350 l/min02QI (Microglass)
EPF4202QIBM3MG201
Quote Required
TBD
ParkerConstructionHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil Filters5 barMarine Steering UnitsiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile2 µmStandard, incl. BypassVisual7.0 barG1¼0 to 350 l/min02QI (Microglass)7.002QI (Microglass)0 to 350G1-1/4
EPF4202QIBPKG241
Quote Required
TBD
ParkerInlineAgricultureHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.-40 to 100 °CHydraulic Oil FiltersNo IndicatorMarine Steering UnitsiProtect® EPFInline Filter6500 psiHousing: Iron/SteelNitrile2 µmStandard, incl. BypassPlugged with steel plug3.5 barG1½0 to 350 l/min02QI (Microglass)3.502QI (Microglass)0 to 350G1-1/2
EPF4202QIBPMG201
Quote Required
TBD
ParkerOil and GasHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAHydraulicsHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil FiltersNo IndicatorHarvestersiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile2 µmStandard, incl. BypassPlugged with steel plug7.0 barG1¼0 to 350 l/min02QI (Microglass)7.002QI (Microglass)0 to 350G1-1/4
EPF4202QIBT1KX201
Quote Required
TBD
ParkerConstructionHydraulic & Industrial Process Filtration Division EMEAHydraulic & Industrial Process Filtration Division EMEAFiltrationHydraulic OilDegree of filtration determined by multipass test according to ISO 16889.Hydraulic Oil Filters2.5 barHydraulic PressesiProtect® EPFInline Filter450 barHousing: Iron/SteelNitrile2 µmStandard, incl. BypassElectrical NO/NC3.5 barManifold Ø34 mm0 to 350 l/min02QI (Microglass)3.502QI (Microglass)0 to 350Manifold Ø34 mm