- Availability & Price
- Search SKU
Filter by attributes
- Bypass Valve Pressure Rating
- Connection Type
- Filter Element Type
- Flow Rate
- Indicator Pressure Setting
- Indicator Type
- Length
- Micron Rating
- Operating Temperature
- Options
Filter by manufacturer
High Pressure In-Line Filter - 18/28/38P Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The 18/28/38P series of high pressure filters is designed to satisfy demanding applications in the global mobile and industrial markets. With metric mounting and optional ISO 6149 ports, this high pressure filter series is truly a global design. This filter series has a wide range of high capacity and low initial differential pressure elements, offering excellent protection to system components.
Standard filters come complete with an industry proven spool type bypass valve. For more critical applications such as servo or proportional controls, a no bypass, high strength element combination ensures maximum protection.
The low hysteresis differential pressure indicator fitted to this series is unrivalled in its performance.
Applications
• Mobile working hydraulics
• Mobile drive system
• Injection moulding
• Servo controls
• Die casting
• Machine tools
Read More...Standard filters come complete with an industry proven spool type bypass valve. For more critical applications such as servo or proportional controls, a no bypass, high strength element combination ensures maximum protection.
The low hysteresis differential pressure indicator fitted to this series is unrivalled in its performance.
Applications
• Mobile working hydraulics
• Mobile drive system
• Injection moulding
• Servo controls
• Die casting
• Machine tools
| Action | Part No. | Availability | Partner Available | Price | Division | Seal Material | Micron Rating | Length | Filter Element Type | Options | Indicator Pressure Setting | Indicator Type | Operating Temperature | Bypass Valve Pressure Rating | Connection Type | Flow Rate |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 28P210QBNMG161S02 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 2 | 10Q Microglass | No bypass | No indicator | No indicator port | -40/+100°C | 7.0 bar | Thread G1" | 0-290 l/min | ||
| 28P210QBPMG161 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 2 | 10Q Microglass | Standard, incl. Bypass | No indicator | Plugged with steel plug | -40/+100°C | 7.0 bar | Thread G1" | 0-290 l/min | ||
| 28P210QBT1KG161 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 2 | 10Q Microglass | Standard, incl. Bypass | 2.5 bar | Electrical NO/NC | -40/+100°C | 3.5 bar | Thread G1" | 0-200 l/min | ||
| 28P210QBT1MG161 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 2 | 10Q Microglass | Standard, incl. Bypass | 5.0 bar | Electrical NO/NC | -40/+100°C | 7.0 bar | Thread G1" | 0-290 l/min | ||
| 28P210QBT1MG162 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 2 | 10Q Microglass | No bypass | 5.0 bar | Electrical NO/NC | -40/+100°C | 7.0 bar | Thread G1" | 0-290 l/min | ||
| 28P210QBT1MH161 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 2 | 10Q Microglass | Standard, incl. Bypass | 5.0 bar | Electrical NO/NC | -40/+100°C | 7.0 bar | SAE flange 1" 6000-M | 0-290 l/min | ||
| 28P210QHBT1MG162 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 2 | 10QH High Strength Microglass | No bypass | 5.0 bar | Electrical NO/NC | -40/+100°C | 7.0 bar | Thread G1" | 0-220 l/min | ||
| 28P220QBM3MG161 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 20 µm | Length 2 | 20Q Microglass | Standard, incl. Bypass | 5.0 bar | Visual | -40/+100°C | 7.0 bar | Thread G1" | 0-320 l/min | ||
| 28P220QBT1MG161 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 20 µm | Length 2 | 20Q Microglass | Standard, incl. Bypass | 5.0 bar | Electrical NO/NC | -40/+100°C | 7.0 bar | Thread G1" | 0-320 l/min | ||
| 28P220QBT1MS161 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 20 µm | Length 2 | 20Q Microglass | Standard, incl. Bypass | 5.0 bar | Electrical NO/NC | -40/+100°C | 7.0 bar | Thread SAE 16 | 0-320 l/min | ||
| 28P220QVM3MG161 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Fluorelastomer | 20 µm | Length 2 | 20Q Microglass | Standard, incl. Bypass | 5.0 bar | Visual | -20/+120°C | 7.0 bar | Thread G1" | 0-320 l/min | ||
| 38P102QBM3MG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 2 µm | Length 1 | 02Q Microglass | Standard, incl. Bypass | 5.0 bar | Visual | -40/+100°C | 7.0 bar | Thread G1¼" | 0-370 l/min | ||
| 38P102QBT1MG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 2 µm | Length 1 | 02Q Microglass | Standard, incl. Bypass | 5.0 bar | Electrical NO/NC | -40/+100°C | 7.0 bar | Thread G1¼" | 0-370 l/min | ||
| 38P105QBF1MG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 5 µm | Length 1 | 05Q Microglass | Standard, incl. Bypass | 5.0 bar | Electronic 4 LED, PNP, N.O. | -40/+100°C | 7.0 bar | Thread G1¼" | 0-430 l/min | ||
| 38P105QBM3MG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 5 µm | Length 1 | 05Q Microglass | Standard, incl. Bypass | 5.0 bar | Visual | -40/+100°C | 7.0 bar | Thread G1¼" | 0-430 l/min | ||
| 38P105QBT1MG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 5 µm | Length 1 | 05Q Microglass | Standard, incl. Bypass | 5.0 bar | Electrical NO/NC | -40/+100°C | 7.0 bar | Thread G1¼" | 0-430 l/min | ||
| 38P110QBM3KG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 1 | 10Q Microglass | Standard, incl. Bypass | 2.5 bar | Visual | -40/+100°C | 3.5 bar | Thread G1¼" | 0-340 l/min | ||
| 38P110QBM3KG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 1 | 10Q Microglass | Standard, incl. Bypass | 2.5 bar | Visual | -40/+100°C | 3.5 bar | Thread G1½" | 0-340 l/min | ||
| 38P110QBM3KH201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 1 | 10Q Microglass | Standard, incl. Bypass | 2.5 bar | Visual | -40/+100°C | 3.5 bar | SAE flange 1¼" 6000-M | 0-340 l/min | ||
| 38P110QBM3MG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 1 | 10Q Microglass | Standard, incl. Bypass | 5.0 bar | Visual | -40/+100°C | 7.0 bar | Thread G1¼" | 0-510 l/min |