High Pressure In-Line Filter - 18/28/38P Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The 18/28/38P series of high pressure filters is designed to satisfy demanding applications in the global mobile and industrial markets. With metric mounting and optional ISO 6149 ports, this high pressure filter series is truly a global design. This filter series has a wide range of high capacity and low initial differential pressure elements, offering excellent protection to system components.
Standard filters come complete with an industry proven spool type bypass valve. For more critical applications such as servo or proportional controls, a no bypass, high strength element combination ensures maximum protection.
The low hysteresis differential pressure indicator fitted to this series is unrivalled in its performance.
Applications
• Mobile working hydraulics
• Mobile drive system
• Injection moulding
• Servo controls
• Die casting
• Machine tools
Read More...Standard filters come complete with an industry proven spool type bypass valve. For more critical applications such as servo or proportional controls, a no bypass, high strength element combination ensures maximum protection.
The low hysteresis differential pressure indicator fitted to this series is unrivalled in its performance.
Applications
• Mobile working hydraulics
• Mobile drive system
• Injection moulding
• Servo controls
• Die casting
• Machine tools
| Action | Part No. | Availability | Partner Available | Price | Division | Seal Material | Indicator Type | Micron Rating | Length | Filter Element Type | Options | Operating Temperature | Indicator Pressure Setting | Bypass Valve Pressure Rating | Flow Rate | Connection Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 38P110QBM3MG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Visual | 10 µm | Length 1 | 10Q Microglass | Standard, incl. Bypass | -40/+100°C | 5.0 bar | 7.0 bar | 0-510 l/min | Thread G1½" | ||
| 38P110QBM3MH201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Visual | 10 µm | Length 1 | 10Q Microglass | Standard, incl. Bypass | -40/+100°C | 5.0 bar | 7.0 bar | 0-510 l/min | SAE flange 1¼" 6000-M | ||
| 38P110QBPMG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Plugged with steel plug | 10 µm | Length 1 | 10Q Microglass | Standard, incl. Bypass | -40/+100°C | No indicator | 7.0 bar | 0-510 l/min | Thread G1¼" | ||
| 38P110QBPMH201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Plugged with steel plug | 10 µm | Length 1 | 10Q Microglass | Standard, incl. Bypass | -40/+100°C | No indicator | 7.0 bar | 0-510 l/min | SAE flange 1¼" 6000-M | ||
| 38P110QBT1KG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Electrical NO/NC | 10 µm | Length 1 | 10Q Microglass | Standard, incl. Bypass | -40/+100°C | 2.5 bar | 3.5 bar | 0-340 l/min | Thread G1¼" | ||
| 38P110QBT1KG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Electrical NO/NC | 10 µm | Length 1 | 10Q Microglass | Standard, incl. Bypass | -40/+100°C | 2.5 bar | 3.5 bar | 0-340 l/min | Thread G1½" | ||
| 38P110QBT1MG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Electrical NO/NC | 10 µm | Length 1 | 10Q Microglass | Standard, incl. Bypass | -40/+100°C | 5.0 bar | 7.0 bar | 0-510 l/min | Thread G1¼" | ||
| 38P110QBT1MG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Electrical NO/NC | 10 µm | Length 1 | 10Q Microglass | Standard, incl. Bypass | -40/+100°C | 5.0 bar | 7.0 bar | 0-510 l/min | Thread G1½" | ||
| 38P110QHBM3MG202 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Visual | 10 µm | Length 1 | 10QH High Strength Microglass | No bypass | -40/+100°C | 5.0 bar | 7.0 bar | 0-290 l/min | Thread G1¼" | ||
| 38P110QHBM3MG241S20 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Visual | 10 µm | Length 1 | 10QH High Strength Microglass | Bypass & high collapse element | -40/+100°C | 5.0 bar | 7.0 bar | 0-290 l/min | Thread G1½" | ||
| 38P110QHVM3MG202 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Fluorelastomer | Visual | 10 µm | Length 1 | 10QH High Strength Microglass | No bypass | -20/+120°C | 5.0 bar | 7.0 bar | 0-290 l/min | Thread G1¼" | ||
| 38P120QBM3KG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Visual | 20 µm | Length 1 | 20Q Microglass | Standard, incl. Bypass | -40/+100°C | 2.5 bar | 3.5 bar | 0-360 l/min | Thread G1½" | ||
| 38P120QBM3MG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Visual | 20 µm | Length 1 | 20Q Microglass | Standard, incl. Bypass | -40/+100°C | 5.0 bar | 7.0 bar | 0-550 l/min | Thread G1¼" | ||
| 38P120QBPMH201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Plugged with steel plug | 20 µm | Length 1 | 20Q Microglass | Standard, incl. Bypass | -40/+100°C | No indicator | 7.0 bar | 0-550 l/min | SAE flange 1¼" 6000-M | ||
| 38P202QBM3MG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Visual | 2 µm | Length 2 | 02Q Microglass | Standard, incl. Bypass | -40/+100°C | 5.0 bar | 7.0 bar | 0-500 l/min | Thread G1¼" | ||
| 38P202QHBT1MG202 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Electrical NO/NC | 2 µm | Length 2 | 02QH High Strength Microglass | No bypass | -40/+100°C | 5.0 bar | 7.0 bar | 0-330 l/min | Thread G1¼" | ||
| 38P205QBF2MG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Electronic 4 LED, NPN, N.O. | 5 µm | Length 2 | 05Q Microglass | Standard, incl. Bypass | -40/+100°C | 5.0 bar | 7.0 bar | 0-540 l/min | Thread G1¼" | ||
| 38P205QBM3KH201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Visual | 5 µm | Length 2 | 05Q Microglass | Standard, incl. Bypass | -40/+100°C | 2.5 bar | 3.5 bar | 0-350 l/min | SAE flange 1¼" 6000-M | ||
| 38P205QBM3MG201 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Visual | 5 µm | Length 2 | 05Q Microglass | Standard, incl. Bypass | -40/+100°C | 5.0 bar | 7.0 bar | 0-540 l/min | Thread G1¼" | ||
| 38P205QBT1KG241 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | Electrical NO/NC | 5 µm | Length 2 | 05Q Microglass | Standard, incl. Bypass | -40/+100°C | 2.5 bar | 3.5 bar | 0-350 l/min | Thread G1½" |