High Pressure In-Line Filter - 18/28/38P Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The 18/28/38P series of high pressure filters is designed to satisfy demanding applications in the global mobile and industrial markets. With metric mounting and optional ISO 6149 ports, this high pressure filter series is truly a global design. This filter series has a wide range of high capacity and low initial differential pressure elements, offering excellent protection to system components.
Standard filters come complete with an industry proven spool type bypass valve. For more critical applications such as servo or proportional controls, a no bypass, high strength element combination ensures maximum protection.
The low hysteresis differential pressure indicator fitted to this series is unrivalled in its performance.
Applications
• Mobile working hydraulics
• Mobile drive system
• Injection moulding
• Servo controls
• Die casting
• Machine tools
Read More...Standard filters come complete with an industry proven spool type bypass valve. For more critical applications such as servo or proportional controls, a no bypass, high strength element combination ensures maximum protection.
The low hysteresis differential pressure indicator fitted to this series is unrivalled in its performance.
Applications
• Mobile working hydraulics
• Mobile drive system
• Injection moulding
• Servo controls
• Die casting
• Machine tools
| Action | Part No. | Availability | Partner Available | Price | Division | Seal Material | Micron Rating | Length | Filter Element Type | Indicator Type | Options | Flow Rate | Connection Type | Operating Temperature | Indicator Pressure Setting | Bypass Valve Pressure Rating |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 18P102QBF1MG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 2 µm | Length 1 | 02Q Microglass | Electronic 4 LED, PNP, N.O. | Standard, incl. Bypass | 0-90 l/min | Thread G¾" | -40/+100°C | 5.0 bar | 7.0 bar | ||
| 18P102QBM3MG081 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 2 µm | Length 1 | 02Q Microglass | Visual | Standard, incl. Bypass | 0-90 l/min | Thread G½" | -40/+100°C | 5.0 bar | 7.0 bar | ||
| 18P102QBM3MG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 2 µm | Length 1 | 02Q Microglass | Visual | Standard, incl. Bypass | 0-90 l/min | Thread G¾" | -40/+100°C | 5.0 bar | 7.0 bar | ||
| 18P102QBT1MG081 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 2 µm | Length 1 | 02Q Microglass | Electrical NO/NC | Standard, incl. Bypass | 0-90 l/min | Thread G½" | -40/+100°C | 5.0 bar | 7.0 bar | ||
| 18P102QBT1MG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 2 µm | Length 1 | 02Q Microglass | Electrical NO/NC | Standard, incl. Bypass | 0-90 l/min | Thread G¾" | -40/+100°C | 5.0 bar | 7.0 bar | ||
| 18P102QHBM3MG122 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 2 µm | Length 1 | 02QH High Strenght Microglass | Visual | No bypass | 0-70 l/min | Thread G¾" | -40/+100°C | 5.0 bar | 7.0 bar | ||
| 18P105QBF1KG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 5 µm | Length 1 | 05Q Microglass | Electronic 4 LED, PNP, N.O. | Standard, incl. Bypass | 0-80 l/min | Thread G¾" | -40/+100°C | 2.5 bar | 3.5 bar | ||
| 18P105QBM3MG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 5 µm | Length 1 | 05Q Microglass | Visual | Standard, incl. Bypass | 0-120 l/min | Thread G¾" | -40/+100°C | 5.0 bar | 7.0 bar | ||
| 18P105QBNMG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 5 µm | Length 1 | 05Q Microglass | No indicator port | Standard, incl. Bypass | 0-120 l/min | Thread G¾" | -40/+100°C | No indicator | 7.0 bar | ||
| 18P105QBPMG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 5 µm | Length 1 | 05Q Microglass | Plugged with steel plug | Standard, incl. Bypass | 0-120 l/min | Thread G¾" | -40/+100°C | No indicator | 7.0 bar | ||
| 18P105QBPMG121EX | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 5 µm | Length 1 | 05Q Microglass | Plugged with steel plug | ATEX certified, (Category 2, non-electrical equipment) | 0-120 l/min | Thread G¾" | -40/+100°C | No indicator | 7.0 bar | ||
| 18P105QBT1KG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 5 µm | Length 1 | 05Q Microglass | Electrical NO/NC | Standard, incl. Bypass | 0-80 l/min | Thread G¾" | -40/+100°C | 2.5 bar | 3.5 bar | ||
| 18P105QBT1MG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 5 µm | Length 1 | 05Q Microglass | Electrical NO/NC | Standard, incl. Bypass | 0-120 l/min | Thread G¾" | -40/+100°C | 5.0 bar | 7.0 bar | ||
| 18P105QHBT1MG122 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 5 µm | Length 1 | 05QH High Strength Microglass | Electrical NO/NC | No bypass | 0-90 l/min | Thread G¾" | -40/+100°C | 5.0 bar | 7.0 bar | ||
| 18P105QHVT1MG122 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Fluorelastomer | 5 µm | Length 1 | 05QH High Strength Microglass | Electrical NO/NC | No bypass | 0-90 l/min | Thread G¾" | -20/+120°C | 5.0 bar | 7.0 bar | ||
| 18P105QVM3KG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Fluorelastomer | 5 µm | Length 1 | 05Q Microglass | Visual | Standard, incl. Bypass | 0-80 l/min | Thread G¾" | -20/+120°C | 2.5 bar | 3.5 bar | ||
| 18P105QVT1MG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Fluorelastomer | 5 µm | Length 1 | 05Q Microglass | Electrical NO/NC | Standard, incl. Bypass | 0-120 l/min | Thread G¾" | -20/+120°C | 5.0 bar | 7.0 bar | ||
| 18P110QBF1MG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 1 | 10Q Microglass | Electronic 4 LED, PNP, N.O. | Standard, incl. Bypass | 0-140 l/min | Thread G¾" | -40/+100°C | 5.0 bar | 7.0 bar | ||
| 18P110QBM3KG121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 1 | 10Q Microglass | Visual | Standard, incl. Bypass | 0-90 l/min | Thread G¾" | -40/+100°C | 2.5 bar | 3.5 bar | ||
| 18P110QBM3KS121 | Quote Required | TBD | Hydraulic & Industrial Process Filtration Division EMEA | Nitrile | 10 µm | Length 1 | 10Q Microglass | Visual | Standard, incl. Bypass | 0-90 l/min | Thread SAE 12 | -40/+100°C | 2.5 bar | 3.5 bar |