HDK Series High Pressure Compressed Air Dryer (up to 25 bar g)
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The Parker HDK 25 bar range of high pressure compressed air dryers are designed to dry compressed air and gaseous nitrogen at high pressure levels of up to 25 barg (363 psig) reliably and efficiently to multiple pressure dew point options of -40°C, -25°C and -70°C (-40°F, -13°F and -94°F). HDK series dryers come equipped with integrated Parker pre- and after filtration and are capable of volume flows up to 600 m³/h @ 25 bar g, 35°C (353 cfm @ 725 psi g, 95°F).
Typical applications for HDK series high pressure compressed air dryers are in power stations (i.e. start up of diesel generators) as well as marine applications (i.e. tank ventilation, rope tensioning on off-shore rigs, generator start up etc.).
Features
• Pressure dew point down options available of -40°C, -25°C and -70°C (-40°F, -13°F and -94°F)
• Volume flows up to 600 m³/h @ 25 bar g, 35°C (353 cfm @ 363 psi g, 95°F)
• Pre- and after filters supplied as standard
Scope of Supply
• Ready to install high pressure adsorption dryer including dew-point control and mounted pre-and after filter
• Optional equipment available mounted ex-works
Available Accessories
• Start-up device
• High pressure differential pressure gauges for the filters
Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Typical applications for HDK series high pressure compressed air dryers are in power stations (i.e. start up of diesel generators) as well as marine applications (i.e. tank ventilation, rope tensioning on off-shore rigs, generator start up etc.).
Features
• Pressure dew point down options available of -40°C, -25°C and -70°C (-40°F, -13°F and -94°F)
• Volume flows up to 600 m³/h @ 25 bar g, 35°C (353 cfm @ 363 psi g, 95°F)
• Pre- and after filters supplied as standard
Scope of Supply
• Ready to install high pressure adsorption dryer including dew-point control and mounted pre-and after filter
• Optional equipment available mounted ex-works
Available Accessories
• Start-up device
• High pressure differential pressure gauges for the filters
Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Compatible Prefilter | Maximum Operating Temperature | Minimum Operating Pressure | Minimum Operating Temperature | Maximum Flow Rate | Brand | Maximum Ambient Temperature | Height | Ingress Protection Rating | Width | Connection Type | Pressure Dew Point | Maximum Operating Pressure | Specifications Met | Depth | Product Type | Division | Compatible After Filter | Minimum Ambient Temperature | Electrical Requirements | Weight | Port Size | Maximum Flow Rate | Controller Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| H120/25D0-G230M | Quote Required | TBD | G7/25XP | 50 °C | 58.02 psig | 77 °F | 73.57 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1489 mm | 65 | 786 mm | BSP-P | -40 °C | 362.59 psig | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G7/25V | 1 °C | 230V, 50-60Hz, others on request | 113 kg | 1/2" | 125m³/h @ 25 bar g, 35°C | Multitronic | ||
| H120/25D0-G230MT | Quote Required | TBD | G7/25XP | 122 °F | 58.02 psig | 25 °C | 73.57 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1489 mm | 65 | 786 mm | BSP-P | -40 °C | 362.59 psig | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G7/25V | 1 °C | 230V, 50-60Hz, others on request | 113 kg | 1/2" | 125m³/h @ 25 bar g, 35°C | Multitronic with Dew Point Sensor | ||
| H160/25D0-G230M | Quote Required | TBD | G9/25XP | 50 °C | 4 barg | 25 °C | 105.94 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1489 mm | 65 | 815 mm | BSP-P | -13 to -104 °F | 362.59 psig | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G9/25V | 1 °C | 230V, 50-60Hz, others on request | 153 kg | 3/4" | 180m³/h @ 25 bar g, 35°C | Multitronic | ||
| H160/25D0-G230MT | Quote Required | TBD | G9/25XP | 122 °F | 4 barg | 77 °F | 105.94 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1489 mm | 65 | 815 mm | BSP-P | -25.0 °C | 25 barg | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G9/25V | 1 °C | 230V, 50-60Hz, others on request | 153 kg | 3/4" | 180m³/h @ 25 bar g, 35°C | Multitronic with Dew Point Sensor | ||
| H18/25D0-G230M | Quote Required | TBD | G3/25XP-15G | 50 °C | 58.02 psig | 25 °C | 14.71 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 925 mm | 65 | 675 mm | BSP-P | -40 °C | 362.59 psig | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G3/25V-15G | 1 °C | 230V, 50-60Hz, others on request | 65 kg | 1/2" | 25m³/h @ 25 bar g, 35°C | Multitronic | ||
| H18/25D0-G230MT | Quote Required | TBD | G3/25XP-15G | 122 °F | 4 barg | 25 °C | 14.71 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 925 mm | 65 | 675 mm | BSP-P | -25.0 °C | 25 barg | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G3/25V-15G | 1 °C | 230V, 50-60Hz, others on request | 65 kg | 1/2" | 25m³/h @ 25 bar g, 35°C | Multitronic with Dew Point Sensor | ||
| H210/25D0-G230M | Quote Required | TBD | G9/25XP | 122 °F | 4 barg | 25 °C | 141.26 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1484 mm | 65 | 840 mm | BSP-P | -13 to -104 °F | 25 barg | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G9/25V | 1 °C | 230V, 50-60Hz, others on request | 182 kg | 3/4" | 240m³/h @ 25 bar g, 35°C | Multitronic | ||
| H210/25D0-G230MT | Quote Required | TBD | G9/25XP | 50 °C | 58.02 psig | 25 °C | 141.26 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1484 mm | 65 | 840 mm | BSP-P | -25.0 °C | 25 barg | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G9/25V | 1 °C | 230V, 50-60Hz, others on request | 182 kg | 3/4" | 240m³/h @ 25 bar g, 35°C | Multitronic with Dew Point Sensor | ||
| H360/25D0-G230M | Quote Required | TBD | G11/25XP | 50 °C | 4 barg | 77 °F | 229.55 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1576 mm | 65 | 890 mm | BSP-P | -40 °C | 25 barg | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G11/25V | 1 °C | 230V, 50-60Hz, others on request | 240 kg | 3/4" | 390m³/h @ 25 bar g, 35°C | Multitronic | ||
| H360/25D0-G230MT | Quote Required | TBD | G11/25XP | 50 °C | 4 barg | 25 °C | 229.55 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1576 mm | 65 | 890 mm | BSP-P | -40 °C | 25 barg | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G11/25V | 1 °C | 230V, 50-60Hz, others on request | 240 kg | 3/4" | 390m³/h @ 25 bar g, 35°C | Multitronic with Dew Point Sensor | ||
| H40/25D0-G230M | Quote Required | TBD | G3/25XP-15G | 122 °F | 4 barg | 25 °C | 29.43 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1190 mm | 65 | 735 mm | BSP-P | -40 °C | 362.59 psig | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G3/25V-15G | 1 °C | 230V, 50-60Hz, others on request | 78 kg | 1/2" | 50m³/h @ 25 bar g, 35°C | Multitronic | ||
| H40/25D0-G230MT | Quote Required | TBD | G3/25XP-15G | 122 °F | 4 barg | 77 °F | 29.43 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1190 mm | 65 | 735 mm | BSP-P | -40 °C | 25 barg | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G3/25V-15G | 1 °C | 230V, 50-60Hz, others on request | 78 kg | 1/2" | 50m³/h @ 25 bar g, 35°C | Multitronic with Dew Point Sensor | ||
| H550/25D0-G230M | Quote Required | TBD | G12/25XP-25G | 122 °F | 58.02 psig | 77 °F | 353.15 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1576 mm | 65 | 945 mm | BSP-P | -40 °C | 25 barg | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G12/25V-25G | 1 °C | 230V, 50-60Hz, others on request | 390 kg | 3/4" | 600m³/h @ 25 bar g, 35°C | Multitronic | ||
| H550/25D0-G230MT | Quote Required | TBD | G12/25XP-25G | 50 °C | 4 barg | 77 °F | 353.15 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1576 mm | 65 | 945 mm | BSP-P | -40 °C | 25 barg | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G12/25V-25G | 1 °C | 230V, 50-60Hz, others on request | 390 kg | 3/4" | 600m³/h @ 25 bar g, 35°C | Multitronic with Dew Point Sensor | ||
| H80/25D0-G230M | Quote Required | TBD | G5/25XP-15G | 122 °F | 4 barg | 77 °F | 58.86 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1290 mm | 65 | 790 mm | BSP-P | -13 to -104 °F | 25 barg | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G5/25V-15G | 1 °C | 230V, 50-60Hz, others on request | 104 kg | 1/2" | 100m³/h @ 25 bar g, 35°C | Multitronic | ||
| H80/25D0-G230MT | Quote Required | TBD | G5/25XP-15G | 50 °C | 4 barg | 77 °F | 58.86 CFM at 362.59 psig, PDP to 104°F | Zander | 50 °C | 1290 mm | 65 | 790 mm | BSP-P | -13 to -104 °F | 362.59 psig | PED, others on request | 400 mm | High Pressure Adsorption | Gas Separation and Filtration Division EMEA | G5/25V-15G | 1 °C | 230V, 50-60Hz, others on request | 104 kg | 1/2" | 100m³/h @ 25 bar g, 35°C | Multitronic with Dew Point Sensor |