GH Series High Pressure Compressed Air Filter (for pressures up to 100 bar g)

Picture for category GH Series High Pressure Compressed Air Filter (for pressures up to 100 bar g)

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker GH series high pressure filters are designed to be ideal for high pressure applications up to 100 bar g. The innovative construction features of the filter housing provide a reliable assembly, as well as simple and safe handling for replacing the filter element. One essential construction feature is the double O-ring seal which protects the housing thread against pollution and humidity and therefore prevents the thread from corrosion. Additionally the second O-ring prevents the filter housing parts from over winding.

By fastening the filter element via its base thread screwed on the tie-rod, this provides the greatest operating safety, even under the pressure pulsations in intermittent operation that are common for high pressure applications.

Highly effective pleated media in four different grades provide an element surface that is four times the size, compared to the conventional wrapped design. The result is a reduced flow speed and efficient separation simultaneously with low pressure drop, thus providing cost reduction during operation with reliable separation performance.

Features
• Optimised flow rates and compact filter housing.

• Improved housing design with double O-ring sealing.

• Threaded rod element fixing.

• Pleated elements.

• Complete filter including filter element and manual drain.

• As an option filters are also available without a drain.

• All filter sizes offer connectors for the installation of calibrated differential pressure gauges.

Sizing and Selection
To ensure quoted air purity specification is met, more than one filtration grade may be required.

Important Note: For quoted air purity performance, compressed air filters must be sized correctly for minimum operating pressure and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandTechnologyDivisionIndustryApplicationDivisionWeightProduct TypeResidual Oil ContentElement Change IntervalFilter Efficiency RatingWidthHeightProduct SeriesOperating PressureSpecifications MetPressure DifferentialMaterials of ConstructionDrainFilter TypeConnection TypeFlow RateMicron RatingCompatible ElementOperating TemperatureOperating Temperature
GH3/100VOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA2.8Compressed Air FilterN/A12 months or 6000 hours> 9080.0355.0GH100100.0 barg MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRNoneDry Particulate½ inch BSPP188 m³/hr @ 100 barg (111 cfm @ 1450 psig)Down to 3μm1050V2 to 80°C (35 to 176°F)
GH3/100XP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA2.8 kgCompressed Air Filter0.1 mg/m³ - 0.01 ppm(w12 months or 6000 hours> 99.9999 %80.0 mm14 inchGH100100.0 barg MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRManualOil Removal Filter½ inch BSPP188 m³/hr @ 100 barg (111 cfm @ 1450 psig)Down to 0.01 μm1050XP2 to 80°C (35 to 176°F)
GH3/100ZP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA2.8 kgCompressed Air Filter0.5 mg/m³ - 0.5 ppm(w)12 months or 6000 hours> 99.925 %80.0 mm355.0 mmGH100100.0 barg MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRManualCoalescing & Dry Particulate½ inch BSPP188 m³/hr @ 100 barg (111 cfm @ 1450 psig)Down to 1 μm1050ZP2 to 80°C (35 to 176°F)
GH3/100ZPOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA2.8Compressed Air Filter0.5 mg/m³ - 0.5 ppm(w)12 months or 6000 hours> 99.92580.0355.0GH100100.0 barg MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRNoneCoalescing & Dry Particulate½ inch BSPP188 m³/hr @ 100 barg (111 cfm @ 1450 psig)Down to 1 μm1050ZP2 to 80°C (35 to 176°F)
GH5/100A
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA2.8 kgCompressed Air Filter0.003 mg/m³ - 0.003 ppm(w)When oil vapour is detectedn/a3.1 inch14 inchGH100100.0 barg MaximumPED Fluid Group II, TRSaturated: n/aHousing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRManualOil Vapour Reduction½ inch BSPP268 m³/hr @ 100 barg (158 cfm @ 1450 psig)n/a1070A2 to 50°C (35 to 122°F)
GH5/100V
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA2.8 kgCompressed Air FilterN/A12 months or 6000 hours> 90 %3.1 inch14 inchGH1001450.0 psig MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRManualDry Particulate½ inch BSPP268 m³/hr @ 100 barg (158 cfm @ 1450 psig)Down to 3μm1070V2 to 80°C (35 to 176°F)
GH5/100VOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA2.8Compressed Air FilterN/A12 months or 6000 hours> 9080.0355.0GH100100.0 barg MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRNoneDry Particulate½ inch BSPP268 m³/hr @ 100 barg (158 cfm @ 1450 psig)Down to 3μm1070V2 to 80°C (35 to 176°F)
GH5/100XP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA6 lbCompressed Air Filter0.1 mg/m³ - 0.01 ppm(w12 months or 6000 hours> 99.9999 %80.0 mm355.0 mmGH1001450.0 psig MaximumPED Fluid Group II, TRSaturated: < 400 mbar (< 5.8 psi)Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRManualOil Removal Filter½ inch BSPP268 m³/hr @ 100 barg (158 cfm @ 1450 psig)Down to 0.01 μm1070XP2 to 80°C (35 to 176°F)
GH5/100ZP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA6 lbCompressed Air Filter0.5 mg/m³ - 0.5 ppm(w)12 months or 6000 hours> 99.925 %3.1 inch14 inchGH1001450.0 psig MaximumPED Fluid Group II, TRSaturated: < 370 mbar (< 5.4 psi)Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRManualCoalescing & Dry Particulate½ inch BSPP268 m³/hr @ 100 barg (158 cfm @ 1450 psig)Down to 1 μm1070ZP2 to 80°C (35 to 176°F)
GH5/100ZPOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA2.8Compressed Air Filter0.5 mg/m³ - 0.5 ppm(w)12 months or 6000 hours> 99.92580.0355.0GH100100.0 barg MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRNoneCoalescing & Dry Particulate½ inch BSPP268 m³/hr @ 100 barg (158 cfm @ 1450 psig)Down to 1 μm1070ZP2 to 80°C (35 to 176°F)
GH7/100A
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA3.4 kgCompressed Air Filter0.003 mg/m³ - 0.003 ppm(w)When oil vapour is detectedn/a3.1 inch420.0 mmGH100100.0 barg MaximumPED Fluid Group II, TRSaturated: n/aHousing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRManualOil Vapour Reduction½ inch BSPP469 m³/hr @ 100 barg (276 cfm @ 1450 psig)n/a1140A2 to 50°C (35 to 122°F)
GH7/100V
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA7 lbCompressed Air FilterN/A12 months or 6000 hours> 90 %80.0 mm16.5 inchGH100100.0 barg MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRManualDry Particulate½ inch BSPP469 m³/hr @ 100 barg (276 cfm @ 1450 psig)Down to 3μm1140V2 to 80°C (35 to 176°F)
GH7/100VOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA3.4Compressed Air FilterN/A12 months or 6000 hours> 9080.0420.0GH100100.0 barg MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRNoneDry Particulate½ inch BSPP469 m³/hr @ 100 barg (276 cfm @ 1450 psig)Down to 3μm1140V2 to 80°C (35 to 176°F)
GH7/100XP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA3.4 kgCompressed Air Filter0.1 mg/m³ - 0.01 ppm(w12 months or 6000 hours> 99.9999 %3.1 inch420.0 mmGH100100.0 barg MaximumPED Fluid Group II, TRSaturated: < 400 mbar (< 5.8 psi)Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRManualOil Removal Filter½ inch BSPP469 m³/hr @ 100 barg (276 cfm @ 1450 psig)Down to 0.01 μm1140XP2 to 80°C (35 to 176°F)
GH7/100ZP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA7 lbCompressed Air Filter0.5 mg/m³ - 0.5 ppm(w)12 months or 6000 hours> 99.925 %80.0 mm16.5 inchGH1001450.0 psig MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRManualCoalescing & Dry Particulate½ inch BSPP469 m³/hr @ 100 barg (276 cfm @ 1450 psig)Down to 1 μm1140ZP2 to 80°C (35 to 176°F)
GH7/100ZPOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA3.4Compressed Air Filter0.5 mg/m³ - 0.5 ppm(w)12 months or 6000 hours> 99.92580.0420.0GH100100.0 barg MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Aluminum, anodized<br/><br/>Seal<br/>NBRNoneCoalescing & Dry Particulate½ inch BSPP469 m³/hr @ 100 barg (276 cfm @ 1450 psig)Down to 1 μm1140ZP2 to 80°C (35 to 176°F)
GH9/100A
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA40 lbCompressed Air Filter0.003 mg/m³ - 0.003 ppm(w)When oil vapour is detectedn/a4.6 inch455.0 mmGH1001450.0 psig MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRManualOil Vapour Reduction¾ inch BSPP681 m³/hr @ 100 barg (401 cfm @ 1450 psig)n/a2010A2 to 50°C (35 to 122°F)35 to 122 °F
GH9/100V
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA18.2 kgCompressed Air FilterN/A12 months or 6000 hours> 90 %4.6 inch17.9 inchGH100100.0 barg MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRManualDry Particulate¾ inch BSPP681 m³/hr @ 100 barg (401 cfm @ 1450 psig)Down to 3μm2010V2 to 80°C (35 to 176°F)35 to 176 °F
GH9/100VOA
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA18.2Compressed Air FilterN/A12 months or 6000 hours> 90116.0455.0GH100100.0 barg MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRNoneDry Particulate¾ inch BSPP681 m³/hr @ 100 barg (401 cfm @ 1450 psig)Down to 3μm2010V2 to 80°C (35 to 176°F)2 to 80
GH9/100XP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAIndustrial Manufacturing Equipment<br/> Food & Beverage<br/> Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalCompressed Air and Nitrogen Gas ApplicationsGas Separation and Filtration Division EMEA18.2 kgCompressed Air Filter0.1 mg/m³ - 0.01 ppm(w12 months or 6000 hours> 99.9999 %116.0 mm17.9 inchGH1001450.0 psig MaximumPED Fluid Group II, TRDry: < 300 mbar (< 4.35 psi)<br/>Housing<br/>Steel<br/><br/>Seal<br/>NBRManualOil Removal Filter¾ inch BSPP681 m³/hr @ 100 barg (401 cfm @ 1450 psig)Down to 0.01 μm2010XP2 to 80°C (35 to 176°F)35 to 176 °F