G4 Series Miniature Solenoid Valves

Picture for category G4 Series Miniature Solenoid Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

G4 Series miniature direct-acting valves are available in conventional body 2-Way and 3-Way configurations as well as industrial-grade cartridge-mount versions - for manifold or direct-mount installations.

These compact 1/8" NPT valves are durable, exhibiting life cycles up to 20 million cycles in laboratory conditions. Excellent flow and pressure characteristics, fast response time, and premium materials deliver value in diverse applications.
NSF-certified versions are positioned to comply with safety requirements in food & beverage applications, while the standard 303 stainless steel bodies and FKM seals address diverse industrial and commercial applications.

Industry-leading pressure and flow performance, interchangeable AC and DC coils, and a modular construction facilitate flexible installation for equipment manufacturers and integrators alike.

G4 Series has enhanced the market on manifolds for motion control, instrumentation, dispensing applications, mobile equipment, and more. Unlike typical solenoid operators used with manifolds, the G4 Series cartridge approach simplifies manifold machining. There are less parts to handle, and assembly time greatly reduced. These benefits help equipment OEMs, integrators, and design firms optimized total cost of ownership and footprint. Yet unlike competitive cartridge valve products, G4 Series maintains the high performance specifiations and industrial robustness you’ve come to expect.
Please consult the factory for special options/ configurations.

2-way Miniature Direct Acting valves are available in Normally Closed and Normally Open flow patterns. These conventional and cartridge-mount Safety Shutoff valves are suitable for supply, shutoff, and dosing applications in diverse industries where performance and compact footprint are desired.
3-way Miniature Direct Acting valves are available in normally open, normally closed, or universal operation. These compact valves are suitable for low to medium pressure applications where fast-response, 0 psi operating pressure, and size envelope are key to success.

Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation

Features:
• NSF Cerfieid
• Modular Design
• Long Life; up to 20 million cycles in lab conditions
• Tight Shutoff
• Flexible: Cartridge or Conventional bodies with diverse electrical options

Applications:
• Analyzers and Diagnostic Equipment
• Beverage Dispensing & Vending machines
• Commercial Kitchen
• Commercial Laundry and Dryers
• Gas Analyzers/ Samplers
• Humidification and Misting Equipment
• HVAC damper control
• Instrumentation Equipment
• Irrigation Equipment
• Lubrication Equipment
• Medical and Dental Equipment
• Mobile Fuel Shut Off
• Oil Burners
• Pneumatic Fan Clutch
• Portable Welding Equipment
• Power Take Off (PTO) units
• Selection or diversion of process media
• Single acting spring return cylinder control
• Spraying Equipment
• Textile and Dry Cleaning Equipment
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceDivisionFunctionValve TypeActuation TypeMinimum Pressure DifferentialMediaCoil TypeSeal MaterialInput VoltageIngress Protection RatingBody MaterialPort SizeConfigurationPort TypeInstallationOrifice SizePower ConsumptionMain Flow CoefficientMaximum Fluid TemperaturePreventive Maintenance KitMaximum Ambient TemperatureInsulation ClassSpecifications MetMaximum Pressure Differential
209CL5LV4D6B
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General PurposeDIN 43650A / ISO 4400FKM24IP65Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV43/3280.22240n/a125H (180°C)CURus Safety Shutoff130
209CL5LV4D6E
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General PurposeDIN 43650A / ISO 4400FKM24/60IP65Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV43/328.50.22240n/a135H (180°C)CURus Safety Shutoff320
209CL5LV4D6F
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General PurposeDIN 43650A / ISO 4400FKM120/60IP65Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV43/328.50.22240n/a135H (180°C)CURus Safety Shutoff320
209CL5LV4L2A
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General PurposeOpen Frame, 18" LeadsFKM12Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV43/3280.22240n/a125F (155°C)CURus Safety Shutoff130
209CL5LV4L2B
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0 psiGeneral PurposeOpen Frame, 18" LeadsFKM24 VDCStainless Steel 3033/4-24 UNS-2A inchAll Ports in BodyCartridgeIOM CV43/32 inch8 W0.22 Cv240 °Fn/a125 °FF (155°C)CURus Safety Shutoff130 psi
209CL5LV4L2E
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General PurposeOpen Frame, 18" LeadsFKM24/60Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV43/328.50.22240n/a135F (155°C)CURus Safety Shutoff320
209CL5LV4L2F
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0 psiGeneral PurposeOpen Frame, 18" LeadsFKM110/50 VACStainless Steel 3033/4-24 UNS-2A inchAll Ports in BodyCartridgeIOM CV43/32 inch8.5 W0.22 Cv240 °Fn/a135 °FF (155°C)CURus Safety Shutoff320 psi
209CL5LV4T2A
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General Purpose1/4" Tab/ SpadeFKM12Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV43/3280.22240n/a125F (155°C)CURus Safety Shutoff130
209CL5LV4T2B
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General Purpose1/4" Tab/ SpadeFKM24Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV43/3280.22240n/a125F (155°C)CURus Safety Shutoff130
209CL5LV4T2E
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General Purpose1/4" Tab/ SpadeFKM24/60Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV43/328.50.22240n/a135F (155°C)CURus Safety Shutoff320
209CL5LV4T2F
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General Purpose1/4" Tab/ SpadeFKM120/60Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV43/328.50.22240n/a135F (155°C)CURus Safety Shutoff320
209CL5MV4
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0 psiGeneral PurposeRequires G4 Series Coil KitFKMPressure Vessel Only (AC or DC Voltage)Stainless Steel 3033/4-24 UNS-2A inchAll Ports in BodyCartridgeIOM CV47/64 inch8.5 W (AC)0.28 Cv240 °Fn/a125 °F (DC)100 psi (DC)
209CL5MV4B2A
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General PurposeGrommetFKM12Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV47/6480.28240n/a125F (155°C)CURus Safety Shutoff100
209CL5MV4B2B
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General PurposeGrommetFKM24Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV47/6480.28240n/a125F (155°C)CURus Safety Shutoff100
209CL5MV4B2E
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General PurposeGrommetFKM24/60Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV47/648.50.28240n/a135F (155°C)CURus Safety Shutoff245
209CL5MV4B2F
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General PurposeGrommetFKM120/60Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV47/648.50.28240n/a135F (155°C)CURus Safety Shutoff245
209CL5MV4B4A
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General PurposeLeads-only (Incl. Ground Lead)FKM12Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV47/6480.28240n/a125F (155°C)CURus Safety Shutoff100
209CL5MV4B4B
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0 psiGeneral PurposeLeads-only (Incl. Ground Lead)FKM24 VDCStainless Steel 3033/4-24 UNS-2A inchAll Ports in BodyCartridgeIOM CV47/64 inch8 W0.28 Cv240 °Fn/a125 °FF (155°C)CURus Safety Shutoff100 psi
209CL5MV4B4E
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General PurposeLeads-only (Incl. Ground Lead)FKM24/60Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV47/648.50.28240n/a135F (155°C)CURus Safety Shutoff245
209CL5MV4B4F
Quote Required
TBD
Fluid Control DivisionNormally Closed (NC)2-WayDirect Acting0General PurposeLeads-only (Incl. Ground Lead)FKM120/60Stainless Steel 3033/4-24 UNS-2AAll Ports in BodyCartridgeIOM CV47/648.50.28240n/a135F (155°C)CURus Safety Shutoff245