G4 Series miniature direct-acting valves are available in conventional body 2-Way and 3-Way configurations as well as industrial-grade cartridge-mount versions - for manifold or direct-mount installations.

These compact 1/8" NPT valves are durable, exhibiting life cycles up to 20 million cycles in laboratory conditions. Excellent flow and pressure characteristics, fast response time, and premium materials deliver value in diverse applications.
NSF-certified versions are positioned to comply with safety requirements in food & beverage applications, while the standard 303 stainless steel bodies and FKM seals address diverse industrial and commercial applications.

Industry-leading pressure and flow performance, interchangeable AC and DC coils, and a modular construction facilitate flexible installation for equipment manufacturers and integrators alike.

G4 Series has enhanced the market on manifolds for motion control, instrumentation, dispensing applications, mobile equipment, and more. Unlike typical solenoid operators used with manifolds, the G4 Series cartridge approach simplifies manifold machining. There are less parts to handle, and assembly time greatly reduced. These benefits help equipment OEMs, integrators, and design firms optimized total cost of ownership and footprint. Yet unlike competitive cartridge valve products, G4 Series maintains the high performance specifiations and industrial robustness you’ve come to expect.
Please consult the factory for special options/ configurations.

2-way Miniature Direct Acting valves are available in Normally Closed and Normally Open flow patterns. These conventional and cartridge-mount Safety Shutoff valves are suitable for supply, shutoff, and dosing applications in diverse industries where performance and compact footprint are desired.
3-way Miniature Direct Acting valves are available in normally open, normally closed, or universal operation. These compact valves are suitable for low to medium pressure applications where fast-response, 0 psi operating pressure, and size envelope are key to success.

Markets:
• Commercial Equipment
• Food & Beverage
• Industrial Automation
• Oil & Gas
• Process Control
• Transportation

Features:
• NSF Cerfieid
• Modular Design
• Long Life; up to 20 million cycles in lab conditions
• Tight Shutoff
• Flexible: Cartridge or Conventional bodies with diverse electrical options

Applications:
• Analyzers and Diagnostic Equipment
• Beverage Dispensing & Vending machines
• Commercial Kitchen
• Commercial Laundry and Dryers
• Gas Analyzers/ Samplers
• Humidification and Misting Equipment
• HVAC damper control
• Instrumentation Equipment
• Irrigation Equipment
• Lubrication Equipment
• Medical and Dental Equipment
• Mobile Fuel Shut Off
• Oil Burners
• Pneumatic Fan Clutch
• Portable Welding Equipment
• Power Take Off (PTO) units
• Selection or diversion of process media
• Single acting spring return cylinder control
• Spraying Equipment
• Textile and Dry Cleaning Equipment
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePricePort SizePort TypeDivisionFunctionValve TypeInput VoltageActuation TypeMinimum Pressure DifferentialExhaust Orifice SizeMain Flow CoefficientMediaCoil TypeSeal MaterialMaximum Pressure DifferentialIngress Protection RatingBody MaterialMaximum Fluid TemperatureMaximum Ambient TemperatureInsulation ClassOrifice SizePower ConsumptionSpecifications MetConfigurationPreventive Maintenance KitExhaust Flow CoefficientInstallation
30CC02MV4C4E
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way24/60Direct Acting03/320.25General Purpose1/2" NPT Conduit w/ Leads (Incl. Ground Lead)FKM50IP65Stainless Steel 303240135F (155°C)7/6410CULus General PurposePressure In Body - Out Sleeve4R0020.20IOM 304
30CC02MV4C4F
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way120/60Direct Acting03/320.25General Purpose1/2" NPT Conduit w/ Leads (Incl. Ground Lead)FKM50IP65Stainless Steel 303240135F (155°C)7/6410CULus General PurposePressure In Body - Out Sleeve4R0020.20IOM 304
30CC02MV4D6A
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way12Direct Acting03/320.25General PurposeDIN 43650A / ISO 4400FKM50IP65Stainless Steel 303240125H (180°C)7/648CURus General PurposePressure In Body - Out Sleeve4R0020.20IOM 304
30CC02MV4D6B
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way24Direct Acting03/320.25General PurposeDIN 43650A / ISO 4400FKM50IP65Stainless Steel 303240125H (180°C)7/648CURus General PurposePressure In Body - Out Sleeve4R0020.20IOM 304
30CC02MV4D6E
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way24/60Direct Acting03/320.25General PurposeDIN 43650A / ISO 4400FKM50IP65Stainless Steel 303240135H (180°C)7/6410CURus General PurposePressure In Body - Out Sleeve4R0020.20IOM 304
30CC02MV4D6F
Quote Required
TBD
1/8 inchNPTFluid Control DivisionNormally Closed (NC)3-Way120/60 VACDirect Acting0 psi3/32 inch0.25 CvGeneral PurposeDIN 43650A / ISO 4400FKM50 psiIP65Stainless Steel 303240 °F135 °FH (180°C)7/64 inch10 WCURus General PurposePressure In Body - Out Sleeve4R0020.20 CvIOM 304
30CC02MV4L2A
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way12Direct Acting03/320.25General PurposeOpen Frame, 18" LeadsFKM50Stainless Steel 303240125F (155°C)7/648CURus General PurposePressure In Body - Out Sleeve4R0020.20IOM 304
30CC02MV4L2B
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way24Direct Acting03/320.25General PurposeOpen Frame, 18" LeadsFKM50Stainless Steel 303240125F (155°C)7/648CURus General PurposePressure In Body - Out Sleeve4R0020.20IOM 304
30CC02MV4L2E
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way24/60Direct Acting03/320.25General PurposeOpen Frame, 18" LeadsFKM50Stainless Steel 303240135F (155°C)7/6410CURus General PurposePressure In Body - Out Sleeve4R0020.20IOM 304
30CC02MV4L2F
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way120/60Direct Acting03/320.25General PurposeOpen Frame, 18" LeadsFKM50Stainless Steel 303240135F (155°C)7/6410CURus General PurposePressure In Body - Out Sleeve4R0020.20IOM 304
30CC02PE4
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-WayPressure Vessel Only (AC or DC Voltage)Direct Acting03/320.32General PurposeRequires G4 Series Coil KitEPDM NSF40 psi (AC or DC)Stainless Steel 303240135 °F (AC)1/810 W (AC)All Ports in Bodyn/a0.20IOM 304
30CC02PE4B2A
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way12Direct Acting03/320.32General PurposeGrommetEPDM NSF40Stainless Steel 303240125F (155°C)1/88NSF 169Pressure In Body - Out SleeveConsult Factory0.20IOM 304
30CC02PE4B2B
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way24Direct Acting03/320.32General PurposeGrommetEPDM NSF40Stainless Steel 303240125F (155°C)1/88NSF 169Pressure In Body - Out SleeveConsult Factory0.20IOM 304
30CC02PE4B2E
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way24/60Direct Acting03/320.32General PurposeGrommetEPDM NSF40Stainless Steel 303240135F (155°C)1/810NSF 169Pressure In Body - Out SleeveConsult Factory0.20IOM 304
30CC02PE4B2F
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way120/60Direct Acting03/320.32General PurposeGrommetEPDM NSF40Stainless Steel 303240135F (155°C)1/810NSF 169Pressure In Body - Out SleeveConsult Factory0.20IOM 304
30CC02PE4B4A
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way12Direct Acting03/320.32General PurposeLeads-only (Incl. Ground Lead)EPDM NSF40Stainless Steel 303240125F (155°C)1/88NSF 169Pressure In Body - Out SleeveConsult Factory0.20IOM 304
30CC02PE4B4B
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way24Direct Acting03/320.32General PurposeLeads-only (Incl. Ground Lead)EPDM NSF40Stainless Steel 303240125F (155°C)1/88NSF 169Pressure In Body - Out SleeveConsult Factory0.20IOM 304
30CC02PE4B4E
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way24/60Direct Acting03/320.32General PurposeLeads-only (Incl. Ground Lead)EPDM NSF40Stainless Steel 303240135F (155°C)1/810NSF 169Pressure In Body - Out SleeveConsult Factory0.20IOM 304
30CC02PE4B4F
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way120/60Direct Acting03/320.32General PurposeLeads-only (Incl. Ground Lead)EPDM NSF40Stainless Steel 303240135F (155°C)1/810NSF 169Pressure In Body - Out SleeveConsult Factory0.20IOM 304
30CC02PE4C4A
Quote Required
TBD
1/8NPTFluid Control DivisionNormally Closed (NC)3-Way12Direct Acting03/320.32General Purpose1/2" NPT Conduit w/ Leads (Incl. Ground Lead)EPDM NSF40IP65Stainless Steel 303240125F (155°C)1/88NSF 169Pressure In Body - Out SleeveConsult Factory0.20IOM 304