• Availability & Price
  • Search SKU
Filter by attributes
  • Efficiency Rating %
  • Element Seal Material
  • Filter Housing Series
  • Filter Type
  • Inside Diameter (inch)
  • Length (inch)
  • Maximum Operating Temperature (F)
  • Micron Rating (µm)
  • Quantity per Box
More Filters...
Filter by manufacturer
Manufacturers

Finite ASME Replacement Elements

Picture for category Finite ASME Replacement Elements

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker Finite's ASME filter vessels replacement elements have been designed specifically to incorporate large flow capacities for maximum performance with low differential pressures. With flow capacities up to 37,000 scfm, port sizes to 16", and optional materials of construction, most compressor source filtration requirements can be met.
Parker Finite offers the filter media grades ensuring that we have the correct media choice for nearly any application requirement. Parker offers 8 media choices ranging from the Finite's standard UNI-CAST coalescer in Grades 6, 8, and 10, a high temperature coalescer in Grade 6, 8, and 10, two pleated coalescers, a bulk liquid removal, particulate removal, and an oil vapor (odor) removal elements.

Features/Benefits
• Floor-standing or Line mounted (T-type) configurations available
• Designed per ASME code / CRN (Canadian Registration)
• Max temperature 450°F , Max Pressure 185 PSIG, (higher pressures upon request)
• Each filter vessel has a 1/2" drain and vent ports
• Filter vessels allow for easy element change out
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceDivisionMaximum Operating TemperatureBrandApplicationQuantity per BoxFilter TypeMicron Rating (µm)Length (inch)Efficiency Rating %Element Seal MaterialFilter Housing SeriesInside Diameter (inch)Maximum Operating Temperature (F)
100WS51-280 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division177 °CFiniteCompressed Air and Gas1Water Separator1002899+FluorocarbonHT3-801, FT3-801, FT6-1603, HF3-801, FF3-801, FF6-1603, FF8-1804, FF10-2207, FF12-3011, FF16-36155.1350
100WS85-250 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division177 °CFiniteCompressed Air and Gas1Water Separator1002599+FluorocarbonFT4-1201, FF4-12018.5350
100WS85-360 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division177 °CFiniteCompressed Air and Gas1Water Separator1003699+FluorocarbonFT6-1201, FF6-12018.5350
10CU51-280 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division107 °CFiniteCompressed Air and Gas1Coalescer12895UrethaneHT3-801, FT3-801, FT6-1603, HF3-801, FF3-801, FF6-1603, FF8-1804, FF10-2207, FF12-3011, FF16-36155.1225
10CU85-250 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division107 °CFiniteCompressed Air and Gas1Coalescer12595UrethaneFT4-1201, FF4-12018.5225
10CU85-360 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division107 °CFiniteCompressed Air and Gas1Coalescer13695UrethaneFT6-1201, FF6-12018.5225
10CV51-280 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division177 °CFiniteCompressed Air and Gas1Coalescer12895FluorocarbonHT3-801, FT3-801, FT6-1603, HF3-801, FF3-801, FF6-1603, FF8-1804, FF10-2207, FF12-3011, FF16-36155.1350
10CV85-250 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division177 °CFiniteCompressed Air and Gas1Coalescer12595FluorocarbonFT4-1201, FF4-12018.5350
10CV85-360 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division177 °CFiniteCompressed Air and Gas1Coalescer13695FluorocarbonFT6-1201, FF6-12018.5350
10DS51-280 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division232 °CFiniteCompressed Air and Gas1High Temperature Coalescer12895SiliconeHT3-801, FT3-801, FT6-1603, HF3-801, FF3-801, FF6-1603, FF8-1804, FF10-2207, FF12-3011, FF16-36155.1450
10DS85-250 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division232 °CFiniteCompressed Air and Gas1High Temperature Coalescer12595SiliconeFT4-1201, FF4-12018.5450
10DS85-360 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division232 °CFiniteCompressed Air and Gas1High Temperature Coalescer13695SiliconeFT6-1201, FF6-12018.5450
10DV51-280 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division232 °CFiniteCompressed Air and Gas1High Temperature Coalescer12895FluorocarbonHT3-801, FT3-801, FT6-1603, HF3-801, FF3-801, FF6-1603, FF8-1804, FF10-2207, FF12-3011, FF16-36155.1450
10DV85-250 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division232 °CFiniteCompressed Air and Gas1High Temperature Coalescer12595FluorocarbonFT4-1201, FF4-12018.5450
10DV85-360 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division232 °CFiniteCompressed Air and Gas1High Temperature Coalescer13695FluorocarbonFT6-1201, FF6-12018.5450
10QS51-280 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division177 °CFiniteCompressed Air and Gas1Coalescer w/ built-in prefilter12895SiliconeHT3-801, FT3-801, FT6-1603, HF3-801, FF3-801, FF6-1603, FF8-1804, FF10-2207, FF12-3011, FF16-36155.1350
10QS85-250 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division177 °CFiniteCompressed Air and Gas1Coalescer w/ built-in prefilter12595SiliconeFT4-1201, FF4-12018.5350
10QS85-360 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division177 °CFiniteCompressed Air and Gas1Coalescer w/ built-in prefilter13695SiliconeFT6-1201, FF6-12018.5350
10QU51-280 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division107 °CFiniteCompressed Air and Gas1Coalescer w/ built-in prefilter12895UrethaneHT3-801, FT3-801, FT6-1603, HF3-801, FF3-801, FF6-1603, FF8-1804, FF10-2207, FF12-3011, FF16-36155.1225
10QU85-250 X 1
Quote Required
TBD
Industrial Gas Filtration and Generation Division107 °CFiniteCompressed Air and Gas1Coalescer w/ built-in prefilter12595UrethaneFT4-1201, FF4-12018.5225