EnOxy Oxygen Membrane Modules
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker hollow-fibre membrane modules produce oxygen enriched air from compressed air to offer a cost effective, reliable and safe alternative to traditional oxygen gas supplies.
Parker modules can be built into a custom-made oxygen generator or can be integrated with your process to provide an on-demand, continuous source of oxygen gas.
Oxygen enriched air is used in many health and wellness related applications such as nitrox diving, oxygen bars and oxygen training rooms.
Features and Benefits:
• Less membrane modules needed per nitrogen system
• Use of low pressure standard industrial compressor - No high pressure compressor needed to obtain required nitrogen flow
• Energy savings - Operation at a low pressure requires less energy
• Reduced CO2 emissions - No heater required to open polymer membrane structure, thus reducing the energy consumption
• Robust fibre - Most tolerant fibre to particle contamination
• Large membrane diameter - Lowest membrane module pressure drop
• Factory membrane ageing, pre-delivery - No performance decrease over time due to fibre ageing
• Quick start-up time - Required nitrogen purity is produced instantly, no time needed to heat-up
• Flexible mounting arrangements - Can be mounted horizontal or vertical
• Low noise operation - Radiated noise generated by membrane technology is extremely low
• No maintenance required - No user serviceable parts
• Small system footprint - Less modules needed to produce nitrogen requirements
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Parker modules can be built into a custom-made oxygen generator or can be integrated with your process to provide an on-demand, continuous source of oxygen gas.
Oxygen enriched air is used in many health and wellness related applications such as nitrox diving, oxygen bars and oxygen training rooms.
Features and Benefits:
• Less membrane modules needed per nitrogen system
• Use of low pressure standard industrial compressor - No high pressure compressor needed to obtain required nitrogen flow
• Energy savings - Operation at a low pressure requires less energy
• Reduced CO2 emissions - No heater required to open polymer membrane structure, thus reducing the energy consumption
• Robust fibre - Most tolerant fibre to particle contamination
• Large membrane diameter - Lowest membrane module pressure drop
• Factory membrane ageing, pre-delivery - No performance decrease over time due to fibre ageing
• Quick start-up time - Required nitrogen purity is produced instantly, no time needed to heat-up
• Flexible mounting arrangements - Can be mounted horizontal or vertical
• Low noise operation - Radiated noise generated by membrane technology is extremely low
• No maintenance required - No user serviceable parts
• Small system footprint - Less modules needed to produce nitrogen requirements
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Brand | Technology | Division | Division | Specifications Met | Industry | Application | Product Type | Model Number | Weight | Depth | Length | Diameter | Flow Rate | Port Type | Gas Purity | Inlet Port Size | Outlet Port Size | Gas Type Generated | Inlet Pressure Rating | Outlet Pressure Rating | Electrical Requirements | Maximum Air Inlet Temperature | Inlet Air Quality Specifications | Model Number | Flow Rate | Width |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 159.003477 | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | N/A | Healthcare & Life Sciences | Nitrox Diving | Membrane Gas Separation | EnOxy 608 | 5.3 kg | 4.5 inch | 29.0 inch | 114 mm | 267 | Female BSPP | up to 40 % | G 1 | G 1 | Oxygen Enriched Air | 188.5 | n/a | No | 50 °C | ISO 8573-1:2010 Class 1.4.1 | EnOxy 608 | 267 l/min @ 7 barg / 40% Purity | |||
| 159.003478 | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | N/A | Healthcare & Life Sciences | Nitrox Diving | Membrane Gas Separation | EnOxy 6010 | 18 lb | 139 mm | 736 mm | 139 mm | 525 | Female BSPP | up to 40 % | G 1 | G 1 | Oxygen Enriched Air | 13 | n/a | No | 122 °F | ISO 8573-1:2010 Class 1.4.1 | EnOxy 6010 | 525 l/min @ 7 barg / 40% Purity | |||
| 159.003655 | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | N/A | Healthcare & Life Sciences | Oxygen Training Rooms | Membrane Gas Separation | EnOxy 304 | 5 lb | 2.5 inch | 15.2 inch | 35.4 | Female BSPP | up to 40 % | G 3/8 | G 3/8 | Oxygen Enriched Air | 145 | n/a | No | 45 °C | ISO 8573-1:2010 Class 1.4.1 | EnOxy 304 | 35.4 l/min @ 7 barg / 40% Purity | 80 mm | |||
| 159.003656 | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | N/A | Healthcare & Life Sciences | Oxygen Bars | Membrane Gas Separation | EnOxy 604 | 7 lb | 2.5 inch | 757 mm | 74.8 | Female BSPP | up to 40 % | G 3/8 | G 3/8 | Oxygen Enriched Air | 188.5 | n/a | No | 122 °F | ISO 8573-1:2010 Class 1.4.1 | EnOxy 604 | 74.8 l/min @ 7 barg / 40% Purity | 80 mm | |||
| 159.003657 | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | N/A | Healthcare & Life Sciences | Oxygen Training Rooms | Membrane Gas Separation | EnOxy 606 | 14 lb | 3.3 inch | 29.6 inch | 145 | Female BSPP | up to 40 % | G 3/4 | G 1/2 | Oxygen Enriched Air | 188.5 | n/a | No | 122 °F | ISO 8573-1:2010 Class 1.4.1 | EnOxy 606 | 145 l/min @ 7 barg / 40% Purity | 4.3 inch |