Dual Mode Energy Saving Refrigerated Air Dryer - DRD Series
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
The importance of compressed air as a provider of energy for modern industrial processes is widely known. What is often overlooked is the need to provide quality treatment for this air. In fact, the air entering the system contains moisture which, when cooled, will turn into water, causing extensive damage not only to the compressed air network, but also to the finished product.
These costly contamination problems can be avoided by installing a dual mode refrigerated dryer (ranging from 200 - 3000 scfm), with dual mode energy saving function (cycling/non-cycling) on models DRD325-DRD3000.
Our 4-in-1 heat exchanger offers minimal pressure drops and class leading performance, and significantly increases the efficiency of the whole compressed air treatment process. The innovative dual mode function automatically and continuously adjusts dryer operation to the effective working conditions, minimizing operating costs and maximizing performances.
Compressed air purification equipment must deliver uncompromising performance and reliability while providing the right balance of air quality with the lowest cost of operation. Many manufacturers offer products for the filtration and purification of contaminated compressed air, which are often selected only upon their initial purchase cost, with little or no regard for the air quality they provide, the cost of operation throughout their life or their environmental impact. When purchasing purification equipment, delivered air quality, the overall cost of ownership and the equipment's environmental impact must always be considered.
Features/Benefits
• Optimum dewpoint levels for highest system performance
• Advanced patented design solutions
• Unique 4-in-1 heat exchanger
• High reliability, easy to use and maintain
• Environmental, lowest real operating costs
• Dual mode integrated energy saving no loss level drain with back up timer drain with alarm on models DRD325 - DRD3000
• Extremely low pressure drop design
• Crankcase heaters
• Dual mode energy saving function (cycling/non-cycling) on models DRD325 – DRD300
• Advanced scroll compressor (400 scfm and up)
• Oversized condenser to operate in ambient to 122˚F (50˚C) with pre-filter
• 3rd party performance verified by CAGI
• ETL listed & CRN registered complete unit
• Dryers manufactured in facility certified to ISO9001 and ISO14001
Minimal direct energy costs
The Parker DRD Series Dual Mode Energy Saving Refrigerated Air Dryers are the most energy efficient air dryer on the market, under all operating conditions. DRD Series compliant scroll compressors (DRD400 – DRD3000) lead the market with the lowest full-load power consumption due to its oversized heat exchanger, compliant scroll compressors, R407C environmentally friendly refrigerant and direct operation, avoiding the increased energy consumption of thermal mass-type dryers. It consumes less energy at full load and saves more energy at partial loads. Electrical consumption usually accounts for around 50% of the air dryer's total cost over a five-year period.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorized Parker distributor.
Read More...These costly contamination problems can be avoided by installing a dual mode refrigerated dryer (ranging from 200 - 3000 scfm), with dual mode energy saving function (cycling/non-cycling) on models DRD325-DRD3000.
Our 4-in-1 heat exchanger offers minimal pressure drops and class leading performance, and significantly increases the efficiency of the whole compressed air treatment process. The innovative dual mode function automatically and continuously adjusts dryer operation to the effective working conditions, minimizing operating costs and maximizing performances.
Compressed air purification equipment must deliver uncompromising performance and reliability while providing the right balance of air quality with the lowest cost of operation. Many manufacturers offer products for the filtration and purification of contaminated compressed air, which are often selected only upon their initial purchase cost, with little or no regard for the air quality they provide, the cost of operation throughout their life or their environmental impact. When purchasing purification equipment, delivered air quality, the overall cost of ownership and the equipment's environmental impact must always be considered.
Features/Benefits
• Optimum dewpoint levels for highest system performance
• Advanced patented design solutions
• Unique 4-in-1 heat exchanger
• High reliability, easy to use and maintain
• Environmental, lowest real operating costs
• Dual mode integrated energy saving no loss level drain with back up timer drain with alarm on models DRD325 - DRD3000
• Extremely low pressure drop design
• Crankcase heaters
• Dual mode energy saving function (cycling/non-cycling) on models DRD325 – DRD300
• Advanced scroll compressor (400 scfm and up)
• Oversized condenser to operate in ambient to 122˚F (50˚C) with pre-filter
• 3rd party performance verified by CAGI
• ETL listed & CRN registered complete unit
• Dryers manufactured in facility certified to ISO9001 and ISO14001
Minimal direct energy costs
The Parker DRD Series Dual Mode Energy Saving Refrigerated Air Dryers are the most energy efficient air dryer on the market, under all operating conditions. DRD Series compliant scroll compressors (DRD400 – DRD3000) lead the market with the lowest full-load power consumption due to its oversized heat exchanger, compliant scroll compressors, R407C environmentally friendly refrigerant and direct operation, avoiding the increased energy consumption of thermal mass-type dryers. It consumes less energy at full load and saves more energy at partial loads. Electrical consumption usually accounts for around 50% of the air dryer's total cost over a five-year period.
For more information or a detailed discussion about your specific requirements please contact Parker or an authorized Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Maximum Inlet Pressure Rating | Compatible Prefilter | Refrigerant Type | Maximum Operating Temperature | Weight | Height | Optional Accessories | Compatible Prefilter Element | Maximum Flow Rate | Compatible After Filter Element | Minimum Operating Pressure | Connection Type | Minimum Operating Temperature | Maximum Operating Pressure | Width | Compatible After Filter | Product Type | Division | Brand | Maximum Ambient Temperature | Installed Condensate Drain Type | Minimum Ambient Temperature | Depth | Electrical Requirements | Maximum Flow Rate (cfm) | Pressure Dew Point (F) |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| DRD1000-460360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 551 | 52 | Pre and After Filtration | Consult Factory | 1699 | Consult Factory | 60 | 3" NPT-M | 65 | 203 | 31.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 45.9 | 460V/3Ph/60Hz | 1000 | < 44 | ||
| DRD1000-575360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 551 | 52 | Pre and After Filtration | Consult Factory | 1699 | Consult Factory | 60 | 3" NPT-M | 65 | 203 | 31.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 45.9 | 575V/3Ph/60Hz | 1000 | < 44 | ||
| DRD1200-460360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 816 | 66.5 | Pre and After Filtration | Consult Factory | 2038.8 | Consult Factory | 60 | 3" NPT-M | 65 | 203 | 39.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 43.2 | 460V/3Ph/60Hz | 1200 | < 44 | ||
| DRD1200-575360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 816 | 66.5 | Pre and After Filtration | Consult Factory | 2038.8 | Consult Factory | 60 | 3" NPT-M | 65 | 203 | 39.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 43.2 | 575V/3Ph/60Hz | 1200 | < 44 | ||
| DRD1600-460360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 1279 | 67.8 | Pre and After Filtration | Consult Factory | 2718.4 | Consult Factory | 60 | 4" Flg | 65 | 203 | 39.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 71.2 | 460V/3Ph/60Hz | 1600 | < 44 | ||
| DRD1600-575360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 1279 | 67.8 | Pre and After Filtration | Consult Factory | 2718.4 | Consult Factory | 60 | 4" Flg | 65 | 203 | 39.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 71.2 | 575V/3Ph/60Hz | 1600 | < 44 | ||
| DRD2000-460360-** | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 1477 | 67.8 | Pre and After Filtration | Consult Factory | 3398 | Consult Factory | 60 | 6" Flg | 65 | 203 | 39.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 71.2 | 460V/3Ph/60Hz | 2000 | < 44 | ||
| DRD2000-575360-** | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 1477 | 67.8 | Pre and After Filtration | Consult Factory | 3398 | Consult Factory | 60 | 6" Flg | 65 | 203 | 39.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 71.2 | 575V/3Ph/60Hz | 2000 | < 44 | ||
| DRD200-230160-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 183 | 38.3 | Pre and After Filtration | Consult Factory | 339.8 | Consult Factory | 60 | 1 1/2" NPT-F | 65 | 203 | 27.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Timed or Electronic | 41 | 22.1 | 230V/1Ph/60Hz | 200 | < 44 | ||
| DRD2400-460360-** | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 1521 | 67.8 | Pre and After Filtration | Consult Factory | 4077.6 | Consult Factory | 60 | 6" Flg | 65 | 203 | 39.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 71.2 | 460V/3Ph/60Hz | 2400 | < 44 | ||
| DRD2400-575360-** | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 1521 | 67.8 | Pre and After Filtration | Consult Factory | 4077.6 | Consult Factory | 60 | 6" Flg | 65 | 203 | 39.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 71.2 | 575V/3Ph/60Hz | 2400 | < 44 | ||
| DRD250-230360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 287 | 41.9 | Pre and After Filtration | Consult Factory | 424.7 | Consult Factory | 60 | 1 1/2" NPT-F | 65 | 203 | 27.8 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Timed or Electronic | 41 | 41.2 | 230V/3Ph/60Hz | 250 | < 44 | ||
| DRD250-460360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 287 | 41.9 | Pre and After Filtration | Consult Factory | 424.7 | Consult Factory | 60 | 1 1/2" NPT-F | 65 | 203 | 27.8 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Timed or Electronic | 41 | 41.2 | 460V/3Ph/60Hz | 250 | < 44 | ||
| DRD250-575360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 287 | 41.9 | Pre and After Filtration | Consult Factory | 424.7 | Consult Factory | 60 | 1 1/2" NPT-F | 65 | 203 | 27.8 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Timed or Electronic | 41 | 41.2 | 575V/3Ph/60Hz | 250 | < 44 | ||
| DRD3000-460360-** | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 1609 | 81 | Pre and After Filtration | Consult Factory | 5097 | Consult Factory | 60 | 6" Flg | 65 | 203 | 39.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 71.2 | 460V/3Ph/60Hz | 3000 | < 44 | ||
| DRD3000-575360-** | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 1609 | 81 | Pre and After Filtration | Consult Factory | 5097 | Consult Factory | 60 | 6" Flg | 65 | 203 | 39.7 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 71.2 | 575V/3Ph/60Hz | 3000 | < 44 | ||
| DRD325-230360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 320 | 41.9 | Pre and After Filtration | Consult Factory | 509.7 | Consult Factory | 60 | 2" NPT-F | 65 | 203 | 27.8 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 41.2 | 230V/3Ph/60Hz | 325 | < 44 | ||
| DRD325-460360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 320 | 41.9 | Pre and After Filtration | Consult Factory | 509.7 | Consult Factory | 60 | 2" NPT-F | 65 | 203 | 27.8 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 41.2 | 460V/3Ph/60Hz | 325 | < 44 | ||
| DRD325-575360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 320 | 41.9 | Pre and After Filtration | Consult Factory | 509.7 | Consult Factory | 60 | 2" NPT-F | 65 | 203 | 27.8 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 41.2 | 575V/3Ph/60Hz | 325 | < 44 | ||
| DRD400-230360-PA | Quote Required | TBD | 100 | Consult Factory | R407c | 149 | 320 | 41.9 | Pre and After Filtration | Consult Factory | 679.6 | Consult Factory | 60 | 2" NPT-F | 65 | 203 | 27.8 | Consult Factory | Compressed Air - Refrigerated | Industrial Gas Filtration and Generation Division | Parker | 122 | Integrated or Electronic | 41 | 41.2 | 230V/3Ph/60Hz | 400 | < 44 |