• Availability & Price
  • Search SKU
Filter by attributes
  • Electrical Requirements
  • Maximum Flow Rate (cfm)
  • Pressure Dew Point (F)
More Filters...
Filter by manufacturer
Manufacturers

Dual Mode Energy Saving Refrigerated Air Dryer - DRD Series

Picture for category Dual Mode Energy Saving Refrigerated Air Dryer - DRD Series

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

The importance of compressed air as a provider of energy for modern industrial processes is widely known. What is often overlooked is the need to provide quality treatment for this air. In fact, the air entering the system contains moisture which, when cooled, will turn into water, causing extensive damage not only to the compressed air network, but also to the finished product.
These costly contamination problems can be avoided by installing a dual mode refrigerated dryer (ranging from 200 - 3000 scfm), with dual mode energy saving function (cycling/non-cycling) on models DRD325-DRD3000.
Our 4-in-1 heat exchanger offers minimal pressure drops and class leading performance, and significantly increases the efficiency of the whole compressed air treatment process. The innovative dual mode function automatically and continuously adjusts dryer operation to the effective working conditions, minimizing operating costs and maximizing performances.
Compressed air purification equipment must deliver uncompromising performance and reliability while providing the right balance of air quality with the lowest cost of operation. Many manufacturers offer products for the filtration and purification of contaminated compressed air, which are often selected only upon their initial purchase cost, with little or no regard for the air quality they provide, the cost of operation throughout their life or their environmental impact. When purchasing purification equipment, delivered air quality, the overall cost of ownership and the equipment's environmental impact must always be considered.
Features/Benefits
• Optimum dewpoint levels for highest system performance
• Advanced patented design solutions
• Unique 4-in-1 heat exchanger
• High reliability, easy to use and maintain
• Environmental, lowest real operating costs
• Dual mode integrated energy saving no loss level drain with back up timer drain with alarm on models DRD325 - DRD3000
• Extremely low pressure drop design
• Crankcase heaters
• Dual mode energy saving function (cycling/non-cycling) on models DRD325 – DRD300
• Advanced scroll compressor (400 scfm and up)
• Oversized condenser to operate in ambient to 122˚F (50˚C) with pre-filter
• 3rd party performance verified by CAGI
• ETL listed & CRN registered complete unit
• Dryers manufactured in facility certified to ISO9001 and ISO14001
Minimal direct energy costs
The Parker DRD Series Dual Mode Energy Saving Refrigerated Air Dryers are the most energy efficient air dryer on the market, under all operating conditions. DRD Series compliant scroll compressors (DRD400 – DRD3000) lead the market with the lowest full-load power consumption due to its oversized heat exchanger, compliant scroll compressors, R407C environmentally friendly refrigerant and direct operation, avoiding the increased energy consumption of thermal mass-type dryers. It consumes less energy at full load and saves more energy at partial loads. Electrical consumption usually accounts for around 50% of the air dryer's total cost over a five-year period.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorized Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceMaximum Inlet Pressure RatingCompatible PrefilterRefrigerant TypeMaximum Operating TemperatureWeightHeightOptional AccessoriesCompatible Prefilter ElementMaximum Flow RateCompatible After Filter ElementMinimum Operating PressureConnection TypeMinimum Operating TemperatureMaximum Operating PressureWidthCompatible After FilterProduct TypeDivisionBrandMaximum Ambient TemperatureInstalled Condensate Drain TypeMinimum Ambient TemperatureDepthElectrical RequirementsMaximum Flow Rate (cfm)Pressure Dew Point (F)
DRD1000-460360-PA
Quote Required
TBD
100Consult FactoryR407c14955152Pre and After FiltrationConsult Factory1699Consult Factory603" NPT-M6520331.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4145.9460V/3Ph/60Hz1000< 44
DRD1000-575360-PA
Quote Required
TBD
100Consult FactoryR407c14955152Pre and After FiltrationConsult Factory1699Consult Factory603" NPT-M6520331.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4145.9575V/3Ph/60Hz1000< 44
DRD1200-460360-PA
Quote Required
TBD
100Consult FactoryR407c14981666.5Pre and After FiltrationConsult Factory2038.8Consult Factory603" NPT-M6520339.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4143.2460V/3Ph/60Hz1200< 44
DRD1200-575360-PA
Quote Required
TBD
100Consult FactoryR407c14981666.5Pre and After FiltrationConsult Factory2038.8Consult Factory603" NPT-M6520339.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4143.2575V/3Ph/60Hz1200< 44
DRD1600-460360-PA
Quote Required
TBD
100Consult FactoryR407c149127967.8Pre and After FiltrationConsult Factory2718.4Consult Factory604" Flg6520339.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4171.2460V/3Ph/60Hz1600< 44
DRD1600-575360-PA
Quote Required
TBD
100Consult FactoryR407c149127967.8Pre and After FiltrationConsult Factory2718.4Consult Factory604" Flg6520339.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4171.2575V/3Ph/60Hz1600< 44
DRD2000-460360-**
Quote Required
TBD
100Consult FactoryR407c149147767.8Pre and After FiltrationConsult Factory3398Consult Factory606" Flg6520339.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4171.2460V/3Ph/60Hz2000< 44
DRD2000-575360-**
Quote Required
TBD
100Consult FactoryR407c149147767.8Pre and After FiltrationConsult Factory3398Consult Factory606" Flg6520339.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4171.2575V/3Ph/60Hz2000< 44
DRD200-230160-PA
Quote Required
TBD
100Consult FactoryR407c14918338.3Pre and After FiltrationConsult Factory339.8Consult Factory601 1/2" NPT-F6520327.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Timed or Electronic4122.1230V/1Ph/60Hz200< 44
DRD2400-460360-**
Quote Required
TBD
100Consult FactoryR407c149152167.8Pre and After FiltrationConsult Factory4077.6Consult Factory606" Flg6520339.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4171.2460V/3Ph/60Hz2400< 44
DRD2400-575360-**
Quote Required
TBD
100Consult FactoryR407c149152167.8Pre and After FiltrationConsult Factory4077.6Consult Factory606" Flg6520339.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4171.2575V/3Ph/60Hz2400< 44
DRD250-230360-PA
Quote Required
TBD
100Consult FactoryR407c14928741.9Pre and After FiltrationConsult Factory424.7Consult Factory601 1/2" NPT-F6520327.8Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Timed or Electronic4141.2230V/3Ph/60Hz250< 44
DRD250-460360-PA
Quote Required
TBD
100Consult FactoryR407c14928741.9Pre and After FiltrationConsult Factory424.7Consult Factory601 1/2" NPT-F6520327.8Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Timed or Electronic4141.2460V/3Ph/60Hz250< 44
DRD250-575360-PA
Quote Required
TBD
100Consult FactoryR407c14928741.9Pre and After FiltrationConsult Factory424.7Consult Factory601 1/2" NPT-F6520327.8Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Timed or Electronic4141.2575V/3Ph/60Hz250< 44
DRD3000-460360-**
Quote Required
TBD
100Consult FactoryR407c149160981Pre and After FiltrationConsult Factory5097Consult Factory606" Flg6520339.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4171.2460V/3Ph/60Hz3000< 44
DRD3000-575360-**
Quote Required
TBD
100Consult FactoryR407c149160981Pre and After FiltrationConsult Factory5097Consult Factory606" Flg6520339.7Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4171.2575V/3Ph/60Hz3000< 44
DRD325-230360-PA
Quote Required
TBD
100Consult FactoryR407c14932041.9Pre and After FiltrationConsult Factory509.7Consult Factory602" NPT-F6520327.8Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4141.2230V/3Ph/60Hz325< 44
DRD325-460360-PA
Quote Required
TBD
100Consult FactoryR407c14932041.9Pre and After FiltrationConsult Factory509.7Consult Factory602" NPT-F6520327.8Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4141.2460V/3Ph/60Hz325< 44
DRD325-575360-PA
Quote Required
TBD
100Consult FactoryR407c14932041.9Pre and After FiltrationConsult Factory509.7Consult Factory602" NPT-F6520327.8Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4141.2575V/3Ph/60Hz325< 44
DRD400-230360-PA
Quote Required
TBD
100Consult FactoryR407c14932041.9Pre and After FiltrationConsult Factory679.6Consult Factory602" NPT-F6520327.8Consult FactoryCompressed Air - RefrigeratedIndustrial Gas Filtration and Generation DivisionParker122Integrated or Electronic4141.2230V/3Ph/60Hz400< 44