• Availability & Price
  • Search SKU
Filter by attributes
  • Configuration
  • Flow Rate
  • Maximum Inlet Pressure Rating
  • Override Functionality
  • Seal Material
More Filters...
Filter by manufacturer
Manufacturers

Directional Control Proportional Valves

Picture for category Directional Control Proportional Valves

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker’s selection of 3-position, 4-way proportional directional control valves provide predictable and precise controls for applications that require bidirectional flow and controllability. These valves are capable of handling flows up to 32 lpm (8.5 gpm) and pressures as high as 350 bar (5000 psi). These valves can be used in conjunction with an external compensator finer control is required, however these valves are ideal for variable flow actuator or motor applications that need exact control with to ability to stop completely and an acceptable rate of leakage due to the inherent characteristic spool design. Parker’s 3-position, 4-way proportional directional control valves can pair with any Current Controlled Pulse Width Modulation (PWM) valve driver and can be used on a variety of mobile and industrial applications within the agriculture, construction, and manufacturing markets.

Markets:
• Agriculture
• Construction
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• One piece cartridge housing
• Regulates flow proportionally to input solenoid current
• All external parts zinc plated

Applications:
• Applications requiring precise controls
• Variable flow applications
• Actuator control
• Motor speed control

Additional Technical Insight:
Recommended to be used with a Current Controlled Pulse Width Modulation (PWM) valve driver.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMActuation TypeSeal MaterialBody MaterialDivisionMaximum Kinematic ViscosityMinimum Operating TemperatureWeightOverride FunctionalityMaximum Operating PressureMaximum Inlet Pressure RatingOperation TypeInstallation TorqueCoil Nut Tightening TorqueCavity SizeMaximum Operating TemperatureFrequencyFor Fluid TypeValve MaterialOperating TemperatureFilter Efficiency RatingConfigurationCoil TypeResponse TimeMaximum Tank PressureFunctionLeak RateHysteresisFlow Rate AccuracyVariation of Opening PointPower ConsumptionCurrentFlow RateMaximum Flow RateSeal MaterialOverride FunctionalityMaximum Inlet Pressure RatingConfigurationFlow Rate
GP0253V
Quote Required
TBD
ElectricalFluorocarbonn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °F0.15 kgn/a350 bar350 barSolenoid Operated30 Nm3 lb-ftC08-4+204 °C100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-15 to +400 °FISO 4406 18/16/13, SAE Class 4Floating Center1/2" Super Coil50 ms3000 psiProportional Directional Control10 @ 3000 PSI (210 BAR) cm3/minLess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal14, 19 W1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A2.7, 4 Gal/min2.7, 4 Gal/minFluorocarbonN/A5000 PSI, 350 BARFloating Center2.7, 4 GAL/MIN, 10, 15 L/MIN
GP02541N
Quote Required
$178.88
EAElectrical, ManualNitrilen/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-30 °F0.15 kgNon-Detented5000 psi5000 psiSolenoid operated, Manually operated30 Nm4.1 NmC08-4+250 °F100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-30 to +250 °FISO 4406 18/16/13, SAE Class 4Floating Center1/2" Super Coil50 ms3000 psiProportional Directional Control10 @ 3000 PSI (210 BAR) cm3/minLess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal14, 19 W1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A4, 5 Gal/min4, 5 Gal/minNitrileNon-Detented5000 PSI, 350 BARFloating Center4, 5 GAL/MIN, 15, 19 L/MIN
GP02541V
Quote Required
TBD
Electrical, ManualFluorocarbonn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °F0.15 kgNon-Detented350 bar5000 psiSolenoid operated, Manually operated30 Nm3 lb-ftC08-4+204 °C100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-26 to +204 °CISO 4406 18/16/13, SAE Class 4Floating Center1/2" Super Coil50 ms3000 psiProportional Directional Control10 @ 3000 PSI (210 BAR) cm3/minLess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal14, 19 W1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A4, 5 Gal/min15, 19 L/minFluorocarbonNon-Detented5000 PSI, 350 BARFloating Center4, 5 GAL/MIN, 15, 19 L/MIN
GP02542N
Quote Required
TBD
Electrical, ManualNitrilen/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-300.34Detented50005000Solenoid operated, Manually operated223C08-4+250100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-30 to +250ISO 4406 18/16/13, SAE Class 4Floating Center1/2" Super Coil503000Proportional Directional Control10 @ 3000 PSI (210 BAR)Less than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal14, 191.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC4, 54, 5NitrileDetented5000 PSI, 350 BARFloating Center4, 5 GAL/MIN, 15, 19 L/MIN
GP02542V
Quote Required
TBD
Electrical, ManualFluorocarbonn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-150.34Detented50005000Solenoid operated, Manually operated223C08-4+400100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4Floating Center1/2" Super Coil503000Proportional Directional Control10 @ 3000 PSI (210 BAR)Less than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal14, 191.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC4, 54, 5FluorocarbonDetented5000 PSI, 350 BARFloating Center4, 5 GAL/MIN, 15, 19 L/MIN
GP0254N
Quote Required
TBD
ElectricalNitrilen/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-34 °C0.34 lbn/a5000 psi350 barSolenoid Operated30 Nm3 lb-ftC08-4+250 °F100-400 HzMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-34 to +121 °CISO 4406 18/16/13, SAE Class 4Floating Center1/2" Super Coil50 ms3000 psiProportional Directional Control10 @ 3000 PSI (210 BAR) cm3/minLess than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal14, 19 W1.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC A4, 5 Gal/min15, 19 L/minNitrileN/A5000 PSI, 350 BARFloating Center4, 5 GAL/MIN, 15, 19 L/MIN
GP0254V
Quote Required
TBD
ElectricalFluorocarbonn/aHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-150.34n/a50005000Solenoid Operated223C08-4+400100-400Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steel-15 to +400ISO 4406 18/16/13, SAE Class 4Floating Center1/2" Super Coil503000Proportional Directional Control10 @ 3000 PSI (210 BAR)Less than 6%+/- 15% @ 75% Nominal Current and Constant DeltaP Maintained with Pressure Compensator25% - 30% of Input Signal14, 191.15 @ 12 VDC, 1.58 @ 12 VDC, 0.58 @ 24 VDC, 0.79 @ 24 VDC4, 54, 5FluorocarbonN/A5000 PSI, 350 BARFloating Center4, 5 GAL/MIN, 15, 19 L/MIN