Parker’s family of direct acting sequence valves are fast acting and designed for sequenced applications with pressures up to 420 bar (6000 psi) and flows up to 56 lpm (15 gpm) in a variety of sizes. The selection of pressure adjustment styles and piloted or vented controls makes these valves an ideal solution for controlling multiple circuit sections that operate at different pressure settings. Normally-open and normally-closed valves are available in either 2 position 2-way or 2 position 3-way configurations. These direct acting sequence valves can be used within clamping circuits or high/low system applications within several industrial and mobile markets.



Markets:

• Agriculture

• Construction

• Material Handling

• Miscellaneous Industrial

• Miscellaneous Manufacturing

• Miscellaneous Mobile



Features & Benefits:

• Fast response

• Internal mechanical stops limiting spool travel

• Hardened, precision ground parts for durability

• All external parts zinc plated

• Adjustable, fixed, or tamper resistant adjustments available



Applications:

• Dump circuits

• High/low systems

• Sequencing applications



Additional Technical Insight:

Direct acting sequence valves are spool-type devices that allow multiple functions to operate in sequence without the need for solenoid valves, limit switches, or complex control systems.  Parker’s B02, B04, and SV10 sequence valves provide design options for 2-position 2-way or 2-position 3-way sequencing with pilot signals and drains provided internally or externally.  Externally drained versions are not sensitive to downstream pressure if they are drained to the tank. One or more sequence valves can be used in a circuit to allow multiple functions to operate in a specific order based on pressure.  Normally closed and normally open versions are available to allow for design flexibility.



Parker’s B04H4, B04J4, and SV104 series of direct acting sequence valves are Externally Piloted and Externally Drained.  The Normally Closed B04H4 is a 2-position 2-way valve that blocks flow in both directions until an external pilot supply pressure overcomes the sequencing setting.  B04J4 and SV104 are Normally Open 2-position 2-way valves that allow bi-directional flow until the external pilot supply reaches the sequence setting.  All three valves are insensitive to back pressure when their drain line is connected to tank.



Parker’s B04F3, B04G3, B04K4, and SV105 series of direct acting sequence valves are Externally Piloted and Internally Drained.  The Normally Closed B04F3 and SV105 are 2-postion 2-way valves that prevent flow from passing from port 3 to 2 until an external pilot supply pressure overcomes the sequencing setting.  Once the sequence pressure is reached the valve will open allowing flow from port 3 to 2.  B04G3 is a 2-position 2-way Normally Open valve that allows flow from port 2 to 3 until the external pilot pressure reaches the sequence pressure blocking flow from 2 to 3.  B04K4 is a 2-position 3-way normally open valve that allows bi-directional flow between ports 2 and 3 until the sequence pressure is met.  Once the pilot pressure exceeds the set pressure, port 2 is blocked and flow is allowed from port 3 to port 4.  The internal drain causes downstream pressure to be additive to the valves pressure setting, therefore it is most common for the downstream port to be connected to tank.



Parker’s B02E3F and B04E3 direct acting 2-position 3-way sequence valves are Internally Piloted and Internally Drained.  Flow from port 2 to 1 is normally open until the pressure at port 1 exceeds the valves setting which closes port 3 and allows flow from port 1 to port 2.



Parker’s SV103 direct acting 2-position 3-way sequence valve is Internally Piloted and Externally Drained.  Flow from port 1 to 2 is Normally Closed until the pressure at port 1 exceeds the sequence setting which allows flow from port 1 to 2.  Port 3 is a dedicated spring chamber vent which makes the valve insensitive to downstream pressure at port 2.



Please contact us if you have a sequencing application that requires higher flow rates.  Pilot Operated Sequence Valves are capable of flows up to 42 GPM.  Higher flows up to 130 GPM can be achieved with the use of logic elements and small pilot valves.

Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceSeal MaterialBody MaterialMinimum Operating TemperatureFor Fluid TypePilot LocationValve MaterialFilter Efficiency RatingMaximum Kinematic ViscosityMaximum Operating TemperatureFlow RateMaximum Operating PressureMounting TypeActuation TypeDivisionOperation TypeAdjustment MechanismMaximum Tank PressureOperating TemperatureMaximum Inlet Pressure RatingWeightMaximum Flow RateFunctionLeak RateCavity SizeDrain OptionConfigurationInstallation TorqueSealed Pilot IncludedPressure Control RangeMaximum Pressure SettingStandard Setting PressurePressure Control SensitivitySeal MaterialAdjustment MechanismMaximum Inlet Pressure RatingFlow RateSealed Pilot IncludedPressure Control Range
B04E3JWN
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)250136000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-30 to 25060000.613Direct Acting Sequence25 cm3/min @ 870 Psi (60 bar)C10-3InternalSelector50No580 to 350035001750406 psi Per TurnNitrileKnob6000 PSI, 420 BAR13 GAL/MIN, 50 L/MINNo580-3500 PSI, 40-240 BAR
B04E3JWV
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)400136000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-15 to 40060000.613Direct Acting Sequence25 cm3/min @ 870 Psi (60 bar)C10-3InternalSelector50No580 to 350035001750406 psi Per TurnFluorocarbonKnob6000 PSI, 420 BAR13 GAL/MIN, 50 L/MINNo580-3500 PSI, 40-240 BAR
B04E3JZN
Quote Required
TBD
Nitrilen/a-30 °FMineral-based Hydraulic FluidsInternalSteel (all parts)ISO 4406 18/16/1345-2000 SSU (6 to 420 cSt)250 °F50 L/min420 barScrew-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticScrew420 bar-34 to 121 °C420 bar0.6 lb50 L/minDirect Acting Sequence25 cm3/min @ 870 Psi (60 bar)C10-3InternalSelector50 NmNo580 to 3500 psi3500 psi120 bar406 psi Per TurnNitrileScrew6000 PSI, 420 BAR13 GAL/MIN, 50 L/MINNo580-3500 PSI, 40-240 BAR
B04E3JZV
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsInternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)400136000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticScrew6000-15 to 40060000.613Direct Acting Sequence25 cm3/min @ 870 Psi (60 bar)C10-3InternalSelector50No580 to 350035001750406 psi Per TurnFluorocarbonScrew6000 PSI, 420 BAR13 GAL/MIN, 50 L/MINNo580-3500 PSI, 40-240 BAR
B04F3ETN
Quote Required
TBD
Nitrilen/a-34 °CSynthetic Hydraulic FluidsExternalHardened Steel (all operating parts)SAE Class 445-2000 SSU (6 to 420 cSt)121 °C34 L/min420 barScrew-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant420 bar-34 to 121 °C420 bar0.66 lb9 Gal/minDirect Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)37 lb-ftNo30 to 1160 psi1160 psi40 bar8.7 bar Per TurnNitrileTamper Resistant6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINNo30-1160 PSI, 2-80 BAR
B04F3ETNS
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)25096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-30 to 25060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50Yes30 to 11601160580125 psi Per TurnNitrileTamper Resistant6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINYes30-1160 PSI, 2-80 BAR
B04F3ETV
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-15 to 40060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50No30 to 11601160580125 psi Per TurnFluorocarbonTamper Resistant6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINNo30-1160 PSI, 2-80 BAR
B04F3ETVS
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-15 to 40060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50Yes30 to 11601160580125 psi Per TurnFluorocarbonTamper Resistant6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINYes30-1160 PSI, 2-80 BAR
B04F3EWN
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)25096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-30 to 25060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50No30 to 11601160580125 psi Per TurnNitrileKnob6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINNo30-1160 PSI, 2-80 BAR
B04F3EWNS
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)25096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-30 to 25060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50Yes30 to 11601160580125 psi Per TurnNitrileKnob6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINYes30-1160 PSI, 2-80 BAR
B04F3EWV
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-15 to 40060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50No30 to 11601160580125 psi Per TurnFluorocarbonKnob6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINNo30-1160 PSI, 2-80 BAR
B04F3EWVS
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticKnob6000-15 to 40060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50Yes30 to 11601160580125 psi Per TurnFluorocarbonKnob6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINYes30-1160 PSI, 2-80 BAR
B04F3EZN
Quote Required
TBD
Nitrilen/a-30 °FMineral-based Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)121 °C34 L/min6000 psiScrew-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticScrew6000 psi-30 to 250 °F6000 psi0.3 kg9 Gal/minDirect Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)37 lb-ftNo30 to 1160 psi80 bar580 psi125 psi Per TurnNitrileScrew6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINNo30-1160 PSI, 2-80 BAR
B04F3EZNS
Quote Required
TBD
Nitrilen/a-30 °FSynthetic Hydraulic FluidsExternalHardened Steel (all operating parts)SAE Class 445-2000 SSU (6 to 420 cSt)121 °C34 L/min420 barScrew-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticScrew420 bar-30 to 250 °F420 bar0.3 kg9 Gal/minDirect Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50 NmYes2 to 80 bar80 bar40 bar125 psi Per TurnNitrileScrew6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINYes30-1160 PSI, 2-80 BAR
B04F3EZV
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticScrew6000-15 to 40060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50No30 to 11601160580125 psi Per TurnFluorocarbonScrew6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINNo30-1160 PSI, 2-80 BAR
B04F3EZVS
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticScrew6000-15 to 40060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50Yes30 to 11601160580125 psi Per TurnFluorocarbonScrew6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINYes30-1160 PSI, 2-80 BAR
B04F3GTN
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)25096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-30 to 25060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50No30 to 240024001160248 psi Per TurnNitrileTamper Resistant6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINNo30-2400 PSI, 2-166 BAR
B04F3GTNS
Quote Required
TBD
Nitrilen/a-30Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)25096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-30 to 25060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50Yes30 to 240024001160248 psi Per TurnNitrileTamper Resistant6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINYes30-2400 PSI, 2-166 BAR
B04F3GTV
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-15 to 40060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50No30 to 240024001160248 psi Per TurnFluorocarbonTamper Resistant6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINNo30-2400 PSI, 2-166 BAR
B04F3GTVS
Quote Required
TBD
Fluorocarbonn/a-15Synthetic Hydraulic FluidsExternalSteel (all parts)SAE Class 445-2000 SSU (6 to 420 cSt)40096000Screw-in CartridgePressure SensingMobile Hydraulic Systems Division EuropeAutomaticTamper Resistant6000-15 to 40060000.669Direct Acting Sequence25 cm3/min @ 1450 Psi (100 bar)C10-3InternalNormally Closed (NC)50Yes30 to 240024001160248 psi Per TurnFluorocarbonTamper Resistant6000 PSI, 420 BAR9 GAL/MIN, 34 L/MINYes30-2400 PSI, 2-166 BAR