Parker’s selection of direct acting relief valves are fast acting and designed for continuous duty applications with pressures up to 420 bar (6000 psi) and flows up to 200 lpm (53 gpm) in a variety cavity sizes. The variety of pressure adjustment styles available makes these valves an economical solution for clipping pressure spikes and can handle up to full system flow if needed. Poppet style direct acting valves have low leak conditioned seats and are ideal port reliefs in cylinder control applications. Parker’s small, low flow, direct acting valves perform well when controlling pilot circuits or limiting load sense pressure.

Markets:
• Miscellaneous Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Hardened, precision ground parts for durability
• Compact size for reduced space requirements
• Low leakage design poppet design available
• Fast response
• All external parts zinc plated
• High pressure (6000 psi) product available in some models
• Adjustable, fixed, or tamper resistant adjustments available
• Multiple spring ranges are available
• All valves are 100 % tested

Applications:
• Port/cross-port relief
• System relief
• Pilot and/or load sense relief
• Braking

Additional Technical Insight:
Full flow direct acting relief valves can be used as a main system relief valves in low flow circuits.  Direct acting valves are fast acting, therefore, these devices and can be an economical solution for clipping pressure spikes. Poppet style direct acting valves have low leak conditioned seats and are often used as a port relief in a cylinder control applications. Small, low flow, direct acting valves are ideal for controlling pilot circuits or limiting load sense pressure.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBody MaterialMaximum Operating PressureDivisionMaximum Kinematic ViscosityMinimum Operating TemperatureWeightFunctionConfigurationActuation TypeOperation TypeAdjustment MechanismWire Mesh Screen IncludedCavity SizeMaximum Tank PressureSeal MaterialMaximum Inlet Pressure RatingFor Fluid TypeValve MaterialFilter Efficiency RatingMounting TypeOperating TemperatureMaximum Operating TemperatureInstallation TorqueFlow RateMaximum Flow RateMaximum Pressure SettingStandard Setting PressurePressure Control RangePressure Control SensitivityReseat PressureLeak RateAdjustment MechanismSeal MaterialMaximum Inlet Pressure RatingPressure Control RangeFlow Rate
RDH101T10
Quote Required
TBD
n/a5500 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-37 °C0.18 kgDirect ActingPressure ReliefPressure SensingAutomaticTamper Resistantn/aC10-2350 barD-Ring (Standard)380 barMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +200 °F+93 °C50-56 Nm0.5 Gal/min1.9 L/min69 bar34.5 bar100-1000 psi285 per turn psi90% of pressure setting5 @ 75% Crack Pressure drops/minTamper ResistantD-Ring (Standard)5500 PSI, 380 BAR100-1000 PSI, 6.9-69 BAR0.5 GAL/MIN, 1.9 L/MIN
RDH101T10N
Quote Required
TBD
n/a5500Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-300.4Direct ActingPressure ReliefPressure SensingAutomaticTamper Resistantn/aC10-25000Nitrile5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250+25037-410.50.51000500100-1000285 per turn90% of pressure setting5 @ 75% Crack PressureTamper ResistantNitrile5500 PSI, 380 BAR100-1000 PSI, 6.9-69 BAR0.5 GAL/MIN, 1.9 L/MIN
RDH101T10V
Quote Required
TBD
n/a380 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-26 °C0.18 kgDirect ActingPressure ReliefPressure SensingAutomaticTamper Resistantn/aC10-25000 psiFluorocarbon5500 psiMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400 °F+400 °F37-41 lb-ft0.5 Gal/min1.9 L/min1000 psi34.5 bar6.9-69 bar19.6 per turn bar90% of pressure setting5 @ 75% Crack Pressure drops/minTamper ResistantFluorocarbon5500 PSI, 380 BAR100-1000 PSI, 6.9-69 BAR0.5 GAL/MIN, 1.9 L/MIN
RDH101T20
Quote Required
TBD
n/a380 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °F0.4 lbDirect ActingPressure ReliefPressure SensingAutomaticTamper Resistantn/aC10-2350 barD-Ring (Standard)380 barMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +200 °F+93 °C50-56 Nm1.9 L/min1.9 L/min2000 psi69 bar100-2000 psi570 per turn psi90% of pressure setting0.33 @ 75% Crack Pressure cm3/minTamper ResistantD-Ring (Standard)5500 PSI, 380 BAR100-2000 PSI, 6.9-138 BAR0.5 GAL/MIN, 1.9 L/MIN
RDH101T20N
Quote Required
TBD
n/a5500Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-300.4Direct ActingPressure ReliefPressure SensingAutomaticTamper Resistantn/aC10-25000Nitrile5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250+25037-410.50.520001000100-2000570 per turn90% of pressure setting5 @ 75% Crack PressureTamper ResistantNitrile5500 PSI, 380 BAR100-2000 PSI, 6.9-138 BAR0.5 GAL/MIN, 1.9 L/MIN
RDH101T20V
Quote Required
TBD
n/a5500Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-150.4Direct ActingPressure ReliefPressure SensingAutomaticTamper Resistantn/aC10-25000Fluorocarbon5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400+40037-410.50.520001000100-2000570 per turn90% of pressure setting5 @ 75% Crack PressureTamper ResistantFluorocarbon5500 PSI, 380 BAR100-2000 PSI, 6.9-138 BAR0.5 GAL/MIN, 1.9 L/MIN
RDH101T30
Quote Required
TBD
n/a5500 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-35 °F0.18 kgDirect ActingPressure ReliefPressure SensingAutomaticTamper Resistantn/aC10-25000 psiD-Ring (Standard)5500 psiMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +200 °F+200 °F50-56 Nm0.5 Gal/min1.9 L/min3000 psi1500 psi200-3000 psi58.9 per turn bar90% of pressure setting0.33 @ 75% Crack Pressure cm3/minTamper ResistantD-Ring (Standard)5500 PSI, 380 BAR200-3000 PSI, 13.8-210 BAR0.5 GAL/MIN, 1.9 L/MIN
RDH101T30N
Quote Required
TBD
n/a5500Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-300.4Direct ActingPressure ReliefPressure SensingAutomaticTamper Resistantn/aC10-25000Nitrile5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250+25037-410.50.530001500200-3000859 per turn90% of pressure setting5 @ 75% Crack PressureTamper ResistantNitrile5500 PSI, 380 BAR200-3000 PSI, 13.8-210 BAR0.5 GAL/MIN, 1.9 L/MIN
RDH101T30V
Quote Required
TBD
n/a5500 psiHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-26 °C0.4 lbDirect ActingPressure ReliefPressure SensingAutomaticTamper Resistantn/aC10-25000 psiFluorocarbon5500 psiMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400 °F+400 °F50-56 Nm1.9 L/min1.9 L/min3000 psi103.4 bar200-3000 psi58.9 per turn bar90% of pressure setting5 @ 75% Crack Pressure drops/minTamper ResistantFluorocarbon5500 PSI, 380 BAR200-3000 PSI, 13.8-210 BAR0.5 GAL/MIN, 1.9 L/MIN
RDH101T50
Quote Required
TBD
n/a5500Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-350.4Direct ActingPressure ReliefPressure SensingAutomaticTamper Resistantn/aC10-25000D-Ring (Standard)5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-35 to +200+20037-410.50.550002500200-50001910 per turn90% of pressure setting5 @ 75% Crack PressureTamper ResistantD-Ring (Standard)5500 PSI, 380 BAR200-5000 PSI, 13.8-350 BAR0.5 GAL/MIN, 1.9 L/MIN
RDH101T50N
Quote Required
TBD
n/a5500Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-300.4Direct ActingPressure ReliefPressure SensingAutomaticTamper Resistantn/aC10-25000Nitrile5500Mineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-30 to +250+25037-410.50.550002500200-50001910 per turn90% of pressure setting5 @ 75% Crack PressureTamper ResistantNitrile5500 PSI, 380 BAR200-5000 PSI, 13.8-350 BAR0.5 GAL/MIN, 1.9 L/MIN
RDH101T50V
Quote Required
TBD
n/a380 barHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-15 °F0.4 lbDirect ActingPressure ReliefPressure SensingAutomaticTamper Resistantn/aC10-25000 psiFluorocarbon5500 psiMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4Screw in cartridge valve-15 to +400 °F+204 °C37-41 lb-ft1.9 L/min0.5 Gal/min5000 psi172.4 bar13.8-350 bar131.7 per turn bar90% of pressure setting0.33 @ 75% Crack Pressure cm3/minTamper ResistantFluorocarbon5500 PSI, 380 BAR200-5000 PSI, 13.8-350 BAR0.5 GAL/MIN, 1.9 L/MIN