Parker's selection of differential area relief valves provide excellent pressure control in applications where a fast acting, low leakage relief valves are needed with operating pressures up to 380 bar (5500 psi) and flows up to 151 lpm (40 gpm) through a wide selectin of cartridge sizes. Unlike the direct acting family of relief valves, Parker's differential area relief valves are designed to have the pressure controlled at port 2 of the cavity.  This ensures low leakage across the valve, essential in some holding applications.  Designed using industry common cavities, Parker’s line of differential area reliefs can easily be used in various mobile and industrial system applications.

Markets:
• Agriculture
• Aerial
• Construction Equipment
• Industrial
• Miscellaneous Manufacturing
• Miscellaneous Mobile

Features/Benefits:
• Fast acting differential area reliefs for high flow capacity
• Low leak spherical poppets
• High flow capacity
• Mechanical stops eliminate spring solidification
• All external parts zinc plated

Applications:
• Port relief
• Swing relief
• Motor braking
• Cross port relief applications
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBody MaterialSeal MaterialDivisionMaximum Kinematic ViscosityMinimum Operating TemperatureWeightCavity SizeMaximum Operating PressureFunctionActuation TypeOperation TypeMaximum Tank PressurePressure Control SensitivityMaximum Flow RateFlow RateCracking PressureAdjustment MechanismMaximum Inlet Pressure RatingMounting TypeFor Fluid TypeValve MaterialFilter Efficiency RatingOperating TemperatureMaximum Operating TemperatureInstallation TorqueStandard Setting PressurePort Thread SizeMaximum Pressure SettingLeak RateReseat PressureConfigurationPressure Control RangeMinimum Operating PressureSeal MaterialAdjustment MechanismFlow RateCracking PressureMaximum Inlet Pressure RatingMounting TypePressure Control RangeStandard Setting Pressure
RDCH103F20P20V-8T
Quote Required
TBD
SteelFluorocarbonHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-152.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161620Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400N/A1000SAE-820005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-2000380FluorocarbonFixed16 GAL/MIN, 60 L/MIN20 PSI, 1.4 BAR5500 PSI, 380 BARLine Mounted500-2000 PSI, 34.5-138 BAR1000 PSI, 69 BAR
RDCH103F20P50-8T
Quote Required
TBD
SteelD-Ring (Standard)Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-352.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161650Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+200N/A1000SAE-820005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-2000380D-Ring (Standard)Fixed16 GAL/MIN, 60 L/MIN50 PSI, 3.5 BAR5500 PSI, 380 BARLine Mounted500-2000 PSI, 34.5-138 BAR1000 PSI, 69 BAR
RDCH103F20P50N-8T
Quote Required
TBD
SteelNitrileHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-302.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161650Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250N/A1000SAE-820005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-2000380NitrileFixed16 GAL/MIN, 60 L/MIN50 PSI, 3.5 BAR5500 PSI, 380 BARLine Mounted500-2000 PSI, 34.5-138 BAR1000 PSI, 69 BAR
RDCH103F20P50V-8T
Quote Required
TBD
SteelFluorocarbonHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-152.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161650Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400N/A1000SAE-820005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-2000380FluorocarbonFixed16 GAL/MIN, 60 L/MIN50 PSI, 3.5 BAR5500 PSI, 380 BARLine Mounted500-2000 PSI, 34.5-138 BAR1000 PSI, 69 BAR
RDCH103F20P65-8T
Quote Required
TBD
SteelD-Ring (Standard)Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-352.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161665Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+200N/A1000SAE-820005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-2000380D-Ring (Standard)Fixed16 GAL/MIN, 60 L/MIN65 PSI, 4.5 BAR5500 PSI, 380 BARLine Mounted500-2000 PSI, 34.5-138 BAR1000 PSI, 69 BAR
RDCH103F20P65N-8T
Quote Required
TBD
SteelNitrileHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-302.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161665Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250N/A1000SAE-820005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-2000380NitrileFixed16 GAL/MIN, 60 L/MIN65 PSI, 4.5 BAR5500 PSI, 380 BARLine Mounted500-2000 PSI, 34.5-138 BAR1000 PSI, 69 BAR
RDCH103F20P65V-8T
Quote Required
TBD
SteelFluorocarbonHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-152.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161665Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400N/A1000SAE-820005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-2000380FluorocarbonFixed16 GAL/MIN, 60 L/MIN65 PSI, 4.5 BAR5500 PSI, 380 BARLine Mounted500-2000 PSI, 34.5-138 BAR1000 PSI, 69 BAR
RDCH103F20V-8T
Quote Required
TBD
SteelFluorocarbonHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-152.7n/a5500Direct ActingPressure SensingAutomatic5000n/a16165Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400N/A1000SAE-820005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-2000380FluorocarbonFixed16 GAL/MIN, 60 L/MIN5 PSI, 0.3 BAR5500 PSI, 380 BARLine Mounted500-2000 PSI, 34.5-138 BAR1000 PSI, 69 BAR
RDCH103F30-8T
Quote Required
TBD
SteelD-Ring (Standard)Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-352.7n/a5500Direct ActingPressure SensingAutomatic5000n/a16165Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+200N/A1500SAE-830005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-3000380D-Ring (Standard)Fixed16 GAL/MIN, 60 L/MIN5 PSI, 0.3 BAR5500 PSI, 380 BARLine Mounted500-3000 PSI, 34.5-210 BAR1500 PSI, 103.5 BAR
RDCH103F30N-8T
Quote Required
TBD
SteelNitrileHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-302.7n/a5500Direct ActingPressure SensingAutomatic5000n/a16165Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250N/A1500SAE-830005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-3000380NitrileFixed16 GAL/MIN, 60 L/MIN5 PSI, 0.3 BAR5500 PSI, 380 BARLine Mounted500-3000 PSI, 34.5-210 BAR1500 PSI, 103.5 BAR
RDCH103F30P100-8T
Quote Required
TBD
SteelD-Ring (Standard)Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-352.7n/a5500Direct ActingPressure SensingAutomatic5000n/a1616100Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+200N/A1500SAE-830005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-3000380D-Ring (Standard)Fixed16 GAL/MIN, 60 L/MIN100 PSI, 6.9 BAR5500 PSI, 380 BARLine Mounted500-3000 PSI, 34.5-210 BAR1500 PSI, 103.5 BAR
RDCH103F30P100N-8T
Quote Required
TBD
SteelNitrileHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-302.7n/a5500Direct ActingPressure SensingAutomatic5000n/a1616100Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250N/A1500SAE-830005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-3000380NitrileFixed16 GAL/MIN, 60 L/MIN100 PSI, 6.9 BAR5500 PSI, 380 BARLine Mounted500-3000 PSI, 34.5-210 BAR1500 PSI, 103.5 BAR
RDCH103F30P100V-8T
Quote Required
TBD
SteelFluorocarbonHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-152.7n/a5500Direct ActingPressure SensingAutomatic5000n/a1616100Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400N/A1500SAE-830005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-3000380FluorocarbonFixed16 GAL/MIN, 60 L/MIN100 PSI, 6.9 BAR5500 PSI, 380 BARLine Mounted500-3000 PSI, 34.5-210 BAR1500 PSI, 103.5 BAR
RDCH103F30P20-8T
Quote Required
TBD
SteelD-Ring (Standard)Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-352.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161620Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+200N/A1500SAE-830005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-3000380D-Ring (Standard)Fixed16 GAL/MIN, 60 L/MIN20 PSI, 1.4 BAR5500 PSI, 380 BARLine Mounted500-3000 PSI, 34.5-210 BAR1500 PSI, 103.5 BAR
RDCH103F30P20N-8T
Quote Required
TBD
SteelNitrileHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-302.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161620Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250N/A1500SAE-830005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-3000380NitrileFixed16 GAL/MIN, 60 L/MIN20 PSI, 1.4 BAR5500 PSI, 380 BARLine Mounted500-3000 PSI, 34.5-210 BAR1500 PSI, 103.5 BAR
RDCH103F30P20V-8T
Quote Required
TBD
SteelFluorocarbonHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-152.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161620Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400N/A1500SAE-830005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-3000380FluorocarbonFixed16 GAL/MIN, 60 L/MIN20 PSI, 1.4 BAR5500 PSI, 380 BARLine Mounted500-3000 PSI, 34.5-210 BAR1500 PSI, 103.5 BAR
RDCH103F30P50-8T
Quote Required
TBD
SteelD-Ring (Standard)Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-352.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161650Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+200N/A1500SAE-830005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-3000380D-Ring (Standard)Fixed16 GAL/MIN, 60 L/MIN50 PSI, 3.5 BAR5500 PSI, 380 BARLine Mounted500-3000 PSI, 34.5-210 BAR1500 PSI, 103.5 BAR
RDCH103F30P50N-8T
Quote Required
TBD
SteelNitrileHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-302.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161650Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-30 to +250+250N/A1500SAE-830005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-3000380NitrileFixed16 GAL/MIN, 60 L/MIN50 PSI, 3.5 BAR5500 PSI, 380 BARLine Mounted500-3000 PSI, 34.5-210 BAR1500 PSI, 103.5 BAR
RDCH103F30P50V-8T
Quote Required
TBD
SteelFluorocarbonHydraulic Systems Division45-2000 SSU (6 to 420 cSt)-152.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161650Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-15 to +400+400N/A1500SAE-830005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-3000380FluorocarbonFixed16 GAL/MIN, 60 L/MIN50 PSI, 3.5 BAR5500 PSI, 380 BARLine Mounted500-3000 PSI, 34.5-210 BAR1500 PSI, 103.5 BAR
RDCH103F30P65-8T
Quote Required
TBD
SteelD-Ring (Standard)Hydraulic Systems Division45-2000 SSU (6 to 420 cSt)-352.7n/a5500Direct ActingPressure SensingAutomatic5000n/a161665Fixed5500Line MountedMineral-based or synthetic hydraulic fluidsAll parts steel. All operating parts hardened steelISO 4406 18/16/13, SAE Class 4-35 to +200+200N/A1500SAE-830005 @ 75% Crack Pressure85% of pressure settingDifferential Area Relief, Differential Relief w/Reverse Flow Check500-3000380D-Ring (Standard)Fixed16 GAL/MIN, 60 L/MIN65 PSI, 4.5 BAR5500 PSI, 380 BARLine Mounted500-3000 PSI, 34.5-210 BAR1500 PSI, 103.5 BAR