Parker’s DIGI Plus oil test kits provide a condition monitoring tool enabling operators to make informed operational and maintenance decisions about critical plant and equipment. The ability to test on-site at the point of use enables engineers and facilities managers to conduct oil analysis quickly and easily. Detecting out-of-spec fuels and lubricants can identify potential problems before they become critical.
Central to these kits is the DIGI Cell from Parker, which has become the favoured test method for on-site and on-board oil condition monitoring since its introduction in 1993. This was further enhanced with non-hazardous for shipping reagents. Based on extensive experience and feedback from working with marine experts worldwide, Parker created the improved DIGI Plus.
The DIGI Plus added features to make testing easier and more accurate, especially when used in challenging conditions:
• Lightweight
• Backlit display and enhanced keypad
• On-screen step-by-step instructions
• Test result storage and PC download
• Rechargeable battery
Fully portable for use on-board or in the field, test kits are extremely robust, durable and easy to use. The DIGI+ kit contains a test cell together with all necessary reagents and equipment for an easy to use, economical test. Choose from a range of equipment and parameters to use either individually or combined as a single test kit.
Water-in-Oil using DIGI+
• Prevent corrosion, cavitation, or failure of machinery by detecting water in oil, before any damage occurs
• Minimize instability of additive packages and damaging microbe growth by monitoring oil
Saltwater contamination
• Eliminate rapid corrosion in lube oil, fuel or hydraulic systems by checking for the presence of salt
• Provides rapid indication of the presence of salt, even if all the water has been evaporated
Base Number using DIGI+
• Avoid fouling within the engine and corrosion of engine components by monitoring the Base Number (BN) of lubricating oils
Acid Number (AN)
• Measure both the weak organic and strong inorganic acids present within an oil to indicate oil oxidation from 0 to 6 AN due to time or operating temperature
• Simple-to-use drop test. The result is shown by a colour change, providing easily interpretable results
Viscosity
• Widely regarded as an oil’s most important characteristic; showing the oil’s resistance to flow and the strength of the oil film between surfaces
• The Viscostick gives a simple go/no go result. Typically, it will detect 5-10% distillate fuel dilution of an SAE 30 to 40 engine oil as well as increases in viscosity due to oil contamination.
• Measuring oil viscosity provides early detection of contamination, fuel ingress and shear thinning
• Simple, cost-effective equipment requiring no consumables
Insoluble Contamination
• The major contributor is from combustion products, fuel ash, carbon and partially oxidised fuel plus a small contribution of oil oxidation products and spent lubricant additive
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Related Products
Parker’s range of sampling and storage products are designed to get a representative sample for testing in the DIGI+ range of test kits. Also view other products such as the Oil Test Centre for complete testing of fuels and lubricants. Parker also offer sensors in the condition monitoring range – such as FCS, MWDS and offline FWM+ or pqL, to develop a much deeper understanding of health and operating parameters of the machine. See the recommended product section for more details.
Read More...Central to these kits is the DIGI Cell from Parker, which has become the favoured test method for on-site and on-board oil condition monitoring since its introduction in 1993. This was further enhanced with non-hazardous for shipping reagents. Based on extensive experience and feedback from working with marine experts worldwide, Parker created the improved DIGI Plus.
The DIGI Plus added features to make testing easier and more accurate, especially when used in challenging conditions:
• Lightweight
• Backlit display and enhanced keypad
• On-screen step-by-step instructions
• Test result storage and PC download
• Rechargeable battery
Fully portable for use on-board or in the field, test kits are extremely robust, durable and easy to use. The DIGI+ kit contains a test cell together with all necessary reagents and equipment for an easy to use, economical test. Choose from a range of equipment and parameters to use either individually or combined as a single test kit.
Water-in-Oil using DIGI+
• Prevent corrosion, cavitation, or failure of machinery by detecting water in oil, before any damage occurs
• Minimize instability of additive packages and damaging microbe growth by monitoring oil
Saltwater contamination
• Eliminate rapid corrosion in lube oil, fuel or hydraulic systems by checking for the presence of salt
• Provides rapid indication of the presence of salt, even if all the water has been evaporated
Base Number using DIGI+
• Avoid fouling within the engine and corrosion of engine components by monitoring the Base Number (BN) of lubricating oils
Acid Number (AN)
• Measure both the weak organic and strong inorganic acids present within an oil to indicate oil oxidation from 0 to 6 AN due to time or operating temperature
• Simple-to-use drop test. The result is shown by a colour change, providing easily interpretable results
Viscosity
• Widely regarded as an oil’s most important characteristic; showing the oil’s resistance to flow and the strength of the oil film between surfaces
• The Viscostick gives a simple go/no go result. Typically, it will detect 5-10% distillate fuel dilution of an SAE 30 to 40 engine oil as well as increases in viscosity due to oil contamination.
• Measuring oil viscosity provides early detection of contamination, fuel ingress and shear thinning
• Simple, cost-effective equipment requiring no consumables
Insoluble Contamination
• The major contributor is from combustion products, fuel ash, carbon and partially oxidised fuel plus a small contribution of oil oxidation products and spent lubricant additive
For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Related Products
Parker’s range of sampling and storage products are designed to get a representative sample for testing in the DIGI+ range of test kits. Also view other products such as the Oil Test Centre for complete testing of fuels and lubricants. Parker also offer sensors in the condition monitoring range – such as FCS, MWDS and offline FWM+ or pqL, to develop a much deeper understanding of health and operating parameters of the machine. See the recommended product section for more details.
| Action | Part No. | Availability | Partner Available | Price | UOM | Accuracy | Weight | Ingress Protection Rating | Technology | For Fluid Type | Electrical Requirements | Cycle Time | Division | Size | Product Type | Communication Interface | Connection Type | Division | Operating Temperature | Brand | Wetted Material | Industry | Sensing Method | Flow Rate | Sensor Connection | Features | Accessories Included | Sensing Range | Operating Pressure | Signal Output | Function | Options | Materials of Construction | Specifications Met | Diameter | Port Type | Port Size | Minimum Fluid Temperature | Body Material | Seal Material | Maximum Fluid Temperature | Base number | Height | Cycles per Lifetime | Length | Width | For Fluid Type | Product Style | Package Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| ACCK06002 | Quote Required | TBD | |||||||||||||||||||||||||||||||||||||||||||||||
| FG-K1-006-KW | Quote Required | TBD | |||||||||||||||||||||||||||||||||||||||||||||||
| FG-K16822-KW | Quote Required | TBD | |||||||||||||||||||||||||||||||||||||||||||||||
| FG-K2-002-KW | Quote Required | TBD | Water-in-oil: 0.1% up to 1%, then ± 1% above 1%<br/>Base number: ± 5 BN or 10 % (whichever is greater) | 0.2 | IP44 | Filtration | Mineral and synthetic fluids compatible: Lubricant oils, hydraulic oils, distillate fuels, and Bio-based fuels. | Internal USB rechargeable battery (micro-USB: 5 V 100 mA minimum) | Water-in-oil: 180 seconds<br/>Base number: 120 seconds | Hydraulic & Industrial Process Filtration Division EMEA | 76 x 112 mm (Diameter x Height) | Condition Monitoring | Display with backlight and keypad. Computer interface application. | n/a. Manually fed samples | Hydraulic & Industrial Process Filtration Division EMEA | 10 to 45 °C Ambient | Parker | FKM and glass reinforced plastic | Transportation | Electrical sense element | n/a. Manually fed samples | Micro-USB | Fast and effective onsite/Onboard test to measure water-in-oil and/or BN (base number) | Carry case, syringes, reagents, goggles, instructions, 50 tests. | Water-in-oil: 0.02% to 1%, 0.1% to 10%, 0.1% to 20%, 200 ppm to 10000 ppm, 100 ppm to 300 ppm<br/>Base number: 1 to 150 BN | n/a. Manually fed samples | Display computer measurement memory download and setup interface | Reagent pack | BN Reagent Pack 50 tests | ||||||||||||||||||||
| FG-K2-003-KW | Quote Required | TBD | |||||||||||||||||||||||||||||||||||||||||||||||
| FG-K2-101-KW | Quote Required | $739.49 | EA | ||||||||||||||||||||||||||||||||||||||||||||||
| FG-K3-020-KW | Quote Required | TBD | Water-in-oil: 0.1% up to 1%, then ± 1% above 1%<br/>Base number: ± 5 BN or 10 % (whichever is greater) | 0.2 | IP44 | Filtration | Mineral and synthetic fluids compatible: Lubricant oils, hydraulic oils, distillate fuels, and Bio-based fuels. | Internal USB rechargeable battery (micro-USB: 5 V 100 mA minimum) | Water-in-oil: 180 seconds<br/>Base number: 120 seconds | Hydraulic & Industrial Process Filtration Division EMEA | 76 x 112 mm (Diameter x Height) | Condition Monitoring | Display with backlight and keypad. Computer interface application. | n/a. Manually fed samples | Hydraulic & Industrial Process Filtration Division EMEA | 10 to 45 °C Ambient | Parker | FKM and glass reinforced plastic | Transportation | Electrical sense element | n/a. Manually fed samples | Micro-USB | Fast and effective onsite/Onboard test to measure water-in-oil and/or BN (base number) | Carry case, syringes, reagents, goggles, instructions, 50 tests. | Water-in-oil: 0.02% to 1%, 0.1% to 10%, 0.1% to 20%, 200 ppm to 10000 ppm, 100 ppm to 300 ppm<br/>Base number: 1 to 150 BN | n/a. Manually fed samples | Display computer measurement memory download and setup interface | Viscosity | Viscosity (Lube Oil) | ||||||||||||||||||||
| FG-K6-004-KW+ | Quote Required | TBD | ±10% of new oil BN | Packaged 13.5 lb | Filtration | Fuel Oil | Rechargeable Battery | < 3 min | Hydraulic & Industrial Process Filtration Division EMEA | Condition Monitor | USB connection | Hydraulic & Industrial Process Filtration Division EMEA | 10 to 30 °C | Kittiwake | Marine | Pressure Reaction | n/a | n/a | Visual Display | Case: Aluminum or ABS | CE Certification | 77 | N/A | n/a | n/a | Glass Reinforced Plastic | n/a | n/a | 5 to 150 | 112 mm | 500 charge cycles or 3 years | 112 | 77 | System and Cylinder Oils | Water / Total Base Number (TBN) Sensor | ||||||||||||||
| FG-K6-101-KW+ | Quote Required | TBD | ±10% of new oil BN | Packaged 5.7 kg | Filtration | Fuel Oil | Rechargeable Battery | 3 min | Hydraulic & Industrial Process Filtration Division EMEA | Condition Monitor | USB connection | Hydraulic & Industrial Process Filtration Division EMEA | 18 to 65 °C | Kittiwake | Marine | Pressure Reaction | n/a | n/a | Visual Display | Case: Aluminum or ABS | CE Certification | N/A | n/a | n/a | Glass Reinforced Plastic | n/a | n/a | 112 mm | 77 mm | System and Cylinder Oils | Water | Rugged Design Portable Case | |||||||||||||||||
| FG-K6-103-KW+ | Quote Required | TBD | |||||||||||||||||||||||||||||||||||||||||||||||
| FG-K6-108-KW+ | Quote Required | TBD | Packaged 13.5 lb | Filtration | Fuel Oil | Rechargeable Battery | 3 min | Hydraulic & Industrial Process Filtration Division EMEA | Condition Monitor | USB connection | Hydraulic & Industrial Process Filtration Division EMEA | 64 to 149 °F | Kittiwake | Marine | Viscosity: Comparator (Viscostick) | n/a | n/a | TBN/Oil in Water: LCD Display | Case: Aluminum or ABS | CE Certification | N/A | n/a | n/a | DIGI Cell: Glass Reinforced Plastic | n/a | n/a | 112 mm | 77 mm | System and Cylinder Oils | Total Base Number (TBN) Sensor | Rugged Design Portable Case | ||||||||||||||||||
| FG-K6-971-KW+ | Quote Required | TBD | Packaged 13.5 lb | Filtration | Fuel Oil | Rechargeable Battery | 3 min | Hydraulic & Industrial Process Filtration Division EMEA | Condition Monitor | USB connection | Hydraulic & Industrial Process Filtration Division EMEA | 18 to 65 °C | Kittiwake | Marine | TBN/Oil in Water: Electronic Transducer | n/a | n/a | TBN/Oil in Water: LCD Display | Case: Aluminum or ABS | CE Certification | N/A | n/a | n/a | DIGI Cell: Glass Reinforced Plastic | n/a | n/a | 112 mm | 77 mm | Fuel Oil | Total Acid Number (TAN) Sensor | Rugged Design Portable Case |