Parker CDAS Clean Dry Air Systems deliver clean, dry compressed air in accordance with all editions of ISO 8573-1, the international standard for compressed air quality. They are energy efficient and can provide pressure dewpoints of ≤-70°C, ≤-40°C or ≤-20°C at flow rates between 408 m³/hr and 2040 m³/hr @ 7 barg, 35°C for a single bank, higher flows available with multi-banking.

Using clean, dry compressed air improves productivity whilst reducing maintenance costs and downtime. Many products claim to provide this, however CDAS Clean Dry Air Systems provide high levels of compressed air purity with 3rd party validated performance in accordance with international standards.

Product Features
• Supplied with 4 Stages of purification, treating 7 of the 10 main compressed air contaminants (9 with optional liquid separator)
• Constant outlet dewpoint in accordance with ISO 8573-1 classes 1, 2 or 3 for water vapour
• Clean, dry purge air used for regeneration
• Dryer tested in accordance with ISO 7183
• Dewpoint performance 3rd party validated by LRQA
• HL models utilise standard Heatless PSA methodology for desiccant regeneration
• LE models utilise Low Energy vacuum assisted heatless methodology for desiccant regeneration (on average 64% more energy efficient than HL equivalent)
• No heat required for regeneration
• Inlet pressure, temperature and outlet dewpoint measurement as standard
• Colour HMI touch screen for dryer monitoring and outlet dewpoint display
• Two energy saving systems included as standard: Purge Economy (compressor synchronization) and DDS-EST dewpoint dependant switching
• Web Server for dryer monitoring via local area network (LAN)
• MODBUS TCP/IP & MODBUS RTU

To ensure quoted performance, a compressed air dryer must be sized using the correction factors found in the product information sheet.

To discuss your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandTechnologyDivisionDivisionIngress Protection RatingWeightOperating TemperatureNoise LevelAmbient TemperatureDepthWidthHeightIndustryApplicationProduct TypeProduct StyleProduct SeriesOperating PressureSpecifications MetFilter IncludedPower Supply VoltagePort SizeConnection TypeISO GradeFlow RatePressure Dew PointPump Type
CDASHL100-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44235 kg41 to 122 °F< 75 dBA55.0 °C Maximum21.7 inch687.0 mm1647.0 mm• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment – Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100 to 240 VAC (±10%) single phase, 50/60Hz2"BSPPClass 2.2.2 or Class 2.3.2408 m³/h/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL100-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44235 Kg<br/>(518 lbs)5 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)687 mm<br/>(27.0 inch)1647 mm<br/>(64.8 inch)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment – Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100-240V (+/-10%) 1ph 50/60Hz2"NPTClass 2.2.2 or Class 2.3.2408 m³/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL100-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44235 kg5 to 50 °C< 75 dBA131.0 °F Maximum550.0 mm27 inch1647.0 mm• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100 to 240 VAC (±10%) single phase, 50/60Hz2"BSPPClass 2.1.2286 m³/h/hr @ 7 barg, 35°C (168 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL100-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44235 Kg<br/>(518 lbs)5 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)687 mm<br/>(27.0 inch)1647 mm<br/>(64.8 inch)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100-240V (+/-10%) 1ph 50/60Hz2"NPTClass 2.1.2286 m³/hr @ 7 barg, 35°C (168 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL110-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44696 lb41 to 122 °F< 75 dBA131.0 °F Maximum550.0 mm33.7 inch74.5 inch• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment – Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100 to 240 VAC (±10%) single phase, 50/60Hz2"BSPPClass 2.2.2 or Class 2.3.2612 m³/h/hr @ 7 barg, 35°C (360 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL110-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44316 Kg<br/>(696 lbs)5 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1892 mm<br/>(74.5 inch)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment – Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100-240V (+/-10%) 1ph 50/60Hz2"NPTClass 2.2.2 or Class 2.3.2612 m³/hr @ 7 barg, 35°C (360 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL110-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44696 lb41 to 122 °F< 75 dBA131.0 °F Maximum550.0 mm33.7 inch74.5 inch• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100 to 240 VAC (±10%) single phase, 50/60Hz2"BSPPClass 2.1.2428 m³/h/hr @ 7 barg, 35°C (252 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL110-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44316 Kg<br/>(696 lbs)5 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1892 mm<br/>(74.5 inch)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX100-240V (+/-10%) 1ph 50/60Hz2"NPTClass 2.1.2428 m³/hr @ 7 barg, 35°C (252 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL120-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44355 kg5 to 50 °C< 75 dBA55.0 °C Maximum21.7 inch33.7 inch1647.0 mm• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100 to 240 VAC (±10%) single phase, 50/60Hz2½"BSPPClass 2.2.2 or Class 2.3.2765 m³/h/hr @ 7 barg, 35°C (450 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL120-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44355 Kg<br/>(782 lbs)5 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1647 mm<br/>(64.8 inch)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100-240V (+/-10%) 1ph 50/60Hz2½"NPTClass 2.2.2 or Class 2.3.2765 m³/hr @ 7 barg, 35°C (450 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL120-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44782 lb5 to 50 °C< 75 dBA55.0 °C Maximum550.0 mm33.7 inch1647.0 mm• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100 to 240 VAC (±10%) single phase, 50/60Hz2½"BSPPClass 2.1.2536 m³/h/hr @ 7 barg, 35°C (315 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL120-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44355 Kg<br/>(782 lbs)5 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)856 mm<br/>(33.7 inch)1647 mm<br/>(64.8 inch)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100-240V (+/-10%) 1ph 50/60Hz2½"NPTClass 2.1.2536 m³/hr @ 7 barg, 35°C (315 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL130-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44450 kg41 to 122 °F< 75 dBA55.0 °C Maximum21.7 inch1025.0 mm74.5 inch• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 bargPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100 to 240 VAC (±10%) single phase, 50/60Hz2½"BSPPClass 2.2.2 or Class 2.3.21020 m³/h/hr @ 7 barg, 35°C (600 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL130-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44450 Kg<br/>(992 lbs)5 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1025 mm<br/>(40.3 inch)1892 mm<br/>(74.5 inch)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100-240V (+/-10%) 1ph 50/60Hz2½"NPTClass 2.2.2 or Class 2.3.21020 m³/hr @ 7 barg, 35°C (600 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL130-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44992 lb41 to 122 °F< 75 dBA55.0 °C Maximum21.7 inch1025.0 mm1892.0 mm• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100 to 240 VAC (±10%) single phase, 50/60Hz2½"BSPPClass 2.1.2714 m³/h/hr @ 7 barg, 35°C (420 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL130-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44450 Kg<br/>(992 lbs)5 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1025 mm<br/>(40.3 inch)1892 mm<br/>(74.5 inch)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX045HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX045HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX045HGFX100-240V (+/-10%) 1ph 50/60Hz2½"NPTClass 2.1.2714 m³/hr @ 7 barg, 35°C (420 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL140-40G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44543 kg41 to 122 °F< 75 dBA55.0 °C Maximum21.7 inch1194.0 mm1892.0 mm• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX100 to 240 VAC (±10%) single phase, 50/60Hz2½"BSPPClass 2.2.2 or Class 2.3.21275 m³/h/hr @ 7 barg, 35°C (750 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL140-40N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44543 Kg<br/>(1197 lbs)5 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1194 mm<br/>(47.0 inch)1892 mm<br/>(74.5 inch)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX100-240V (+/-10%) 1ph 50/60Hz2½"NPTClass 2.2.2 or Class 2.3.21275 m³/hr @ 7 barg, 35°C (750 cfm @ 102 psig, 95°F)-40°C (-40°F) or -20°C (-4°F) OptionN/A
CDASHL140-70G13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44543 kg5 to 50 °C< 75 dBA131.0 °F Maximum21.7 inch47.0 inch74.5 inch• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)73 to 190 psigPED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX100 to 240 VAC (±10%) single phase, 50/60Hz2½"BSPPClass 2.1.2893 m³/h/hr @ 7 barg, 35°C (525 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A
CDASHL140-70N13BC
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEAIP44543 Kg<br/>(1197 lbs)5 to 50°C<br/>(41 to 122°F)<75 dB(A)55°C (131°F) Maximum550 mm<br/>(21.7 inch)1194 mm<br/>(47.0 inch)1892 mm<br/>(74.5 inch)• General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor ManufacturingCompressed Air Treatment - Clean Dry Air (CDA)Compressed Air Dryer with FiltrationHeatless RegenerationCDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170)5 to 13 barg<br/>(73 to 190 psig)PED 2014/68/EU<b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX100-240V (+/-10%) 1ph 50/60Hz2½"NPTClass 2.1.2893 m³/hr @ 7 barg, 35°C (525 cfm @ 102 psig, 95°F)-70°C (-100°F)N/A