CDAS HL/LE 100-170 Large Flow Heatless Regeneration Compressed Air Treatment System
*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.
Parker CDAS Clean Dry Air Systems deliver clean, dry compressed air in accordance with all editions of ISO 8573-1, the international standard for compressed air quality. They are energy efficient and can provide pressure dewpoints of ≤-70°C, ≤-40°C or ≤-20°C at flow rates between 408 m³/hr and 2040 m³/hr @ 7 barg, 35°C for a single bank, higher flows available with multi-banking.
Using clean, dry compressed air improves productivity whilst reducing maintenance costs and downtime. Many products claim to provide this, however CDAS Clean Dry Air Systems provide high levels of compressed air purity with 3rd party validated performance in accordance with international standards.
Product Features
• Supplied with 4 Stages of purification, treating 7 of the 10 main compressed air contaminants (9 with optional liquid separator)
• Constant outlet dewpoint in accordance with ISO 8573-1 classes 1, 2 or 3 for water vapour
• Clean, dry purge air used for regeneration
• Dryer tested in accordance with ISO 7183
• Dewpoint performance 3rd party validated by LRQA
• HL models utilise standard Heatless PSA methodology for desiccant regeneration
• LE models utilise Low Energy vacuum assisted heatless methodology for desiccant regeneration (on average 64% more energy efficient than HL equivalent)
• No heat required for regeneration
• Inlet pressure, temperature and outlet dewpoint measurement as standard
• Colour HMI touch screen for dryer monitoring and outlet dewpoint display
• Two energy saving systems included as standard: Purge Economy (compressor synchronization) and DDS-EST dewpoint dependant switching
• Web Server for dryer monitoring via local area network (LAN)
• MODBUS TCP/IP & MODBUS RTU
To ensure quoted performance, a compressed air dryer must be sized using the correction factors found in the product information sheet.
To discuss your specific requirements please contact Parker or an authorised Parker distributor.
Read More...Using clean, dry compressed air improves productivity whilst reducing maintenance costs and downtime. Many products claim to provide this, however CDAS Clean Dry Air Systems provide high levels of compressed air purity with 3rd party validated performance in accordance with international standards.
Product Features
• Supplied with 4 Stages of purification, treating 7 of the 10 main compressed air contaminants (9 with optional liquid separator)
• Constant outlet dewpoint in accordance with ISO 8573-1 classes 1, 2 or 3 for water vapour
• Clean, dry purge air used for regeneration
• Dryer tested in accordance with ISO 7183
• Dewpoint performance 3rd party validated by LRQA
• HL models utilise standard Heatless PSA methodology for desiccant regeneration
• LE models utilise Low Energy vacuum assisted heatless methodology for desiccant regeneration (on average 64% more energy efficient than HL equivalent)
• No heat required for regeneration
• Inlet pressure, temperature and outlet dewpoint measurement as standard
• Colour HMI touch screen for dryer monitoring and outlet dewpoint display
• Two energy saving systems included as standard: Purge Economy (compressor synchronization) and DDS-EST dewpoint dependant switching
• Web Server for dryer monitoring via local area network (LAN)
• MODBUS TCP/IP & MODBUS RTU
To ensure quoted performance, a compressed air dryer must be sized using the correction factors found in the product information sheet.
To discuss your specific requirements please contact Parker or an authorised Parker distributor.
| Action | Part No. | Availability | Partner Available | Price | Brand | Technology | Division | Division | Ingress Protection Rating | Operating Temperature | Noise Level | Ambient Temperature | Depth | Width | Height | Weight | Industry | Application | Product Type | Product Style | Product Series | Operating Pressure | Specifications Met | Filter Included | Power Supply Voltage | Connection Type | Port Size | ISO Grade | Flow Rate | Pressure Dew Point | Pump Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| CDASHL150-40G13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 41 to 122 °F | < 75 dBA | 55.0 °C Maximum | 550.0 mm | 53.6 inch | 1892.0 mm | 637 kg | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 73 to 190 psig | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX | 100 to 240 VAC (±10%) single phase, 50/60Hz | BSPP | 2½" | Class 2.2.2 or Class 2.3.2 | 1530 m³/h/hr @ 7 barg, 35°C (900 cfm @ 102 psig, 95°F) | -40°C (-40°F) or -20°C (-4°F) Option | N/A | ||
| CDASHL150-40N13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50°C<br/>(41 to 122°F) | <75 dB(A) | 55°C (131°F) Maximum | 550 mm<br/>(21.7 inch) | 1363 mm<br/>(53.6 inch) | 1892 mm<br/>(74.5 inch) | 637 Kg<br/>(1404 lbs) | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 5 to 13 barg<br/>(73 to 190 psig) | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX | 100-240V (+/-10%) 1ph 50/60Hz | NPT | 2½" | Class 2.2.2 or Class 2.3.2 | 1530 m³/hr @ 7 barg, 35°C (900 cfm @ 102 psig, 95°F) | -40°C (-40°F) or -20°C (-4°F) Option | N/A | ||
| CDASHL150-70G13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50 °C | < 75 dBA | 55.0 °C Maximum | 550.0 mm | 1363.0 mm | 74.5 inch | 1404 lb | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 5 to 13 barg | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX | 100 to 240 VAC (±10%) single phase, 50/60Hz | BSPP | 2½" | Class 2.1.2 | 1071 m³/h/hr @ 7 barg, 35°C (630 cfm @ 102 psig, 95°F) | -70°C (-100°F) | N/A | ||
| CDASHL150-70N13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50°C<br/>(41 to 122°F) | <75 dB(A) | 55°C (131°F) Maximum | 550 mm<br/>(21.7 inch) | 1363 mm<br/>(53.6 inch) | 1892 mm<br/>(74.5 inch) | 637 Kg<br/>(1404 lbs) | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 5 to 13 barg<br/>(73 to 190 psig) | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX050HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX050HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX050HGFX | 100-240V (+/-10%) 1ph 50/60Hz | NPT | 2½" | Class 2.1.2 | 1071 m³/hr @ 7 barg, 35°C (630 cfm @ 102 psig, 95°F) | -70°C (-100°F) | N/A | ||
| CDASHL160-40G13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50 °C | < 75 dBA | 55.0 °C Maximum | 21.7 inch | 1532.0 mm | 1892.0 mm | 731 kg | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 5 to 13 barg | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX | 100 to 240 VAC (±10%) single phase, 50/60Hz | BSPP | 3" | Class 2.2.2 or Class 2.3.2 | 1785 m³/h/hr @ 7 barg, 35°C (1050 cfm @ 102 psig, 95°F) | -40°C (-40°F) or -20°C (-4°F) Option | N/A | ||
| CDASHL160-40N13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50°C<br/>(41 to 122°F) | <75 dB(A) | 55°C (131°F) Maximum | 550 mm<br/>(21.7 inch) | 1532 mm<br/>(60.3 inch) | 1892 mm<br/>(74.5 inch) | 731 Kg<br/>(1611 lbs) | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 5 to 13 barg<br/>(73 to 190 psig) | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX | 100-240V (+/-10%) 1ph 50/60Hz | NPT | 3" | Class 2.2.2 or Class 2.3.2 | 1785 m³/hr @ 7 barg, 35°C (1050 cfm @ 102 psig, 95°F) | -40°C (-40°F) or -20°C (-4°F) Option | N/A | ||
| CDASHL160-70G13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50 °C | < 75 dBA | 131.0 °F Maximum | 21.7 inch | 60.3 inch | 1892.0 mm | 731 kg | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 73 to 190 psig | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX | 100 to 240 VAC (±10%) single phase, 50/60Hz | BSPP | 3" | Class 2.1.2 | 1250 m³/h/hr @ 7 barg, 35°C (735 cfm @ 102 psig, 95°F) | -70°C (-100°F) | N/A | ||
| CDASHL160-70N13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50°C<br/>(41 to 122°F) | <75 dB(A) | 55°C (131°F) Maximum | 550 mm<br/>(21.7 inch) | 1532 mm<br/>(60.3 inch) | 1892 mm<br/>(74.5 inch) | 731 Kg<br/>(1611 lbs) | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 5 to 13 barg<br/>(73 to 190 psig) | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX | 100-240V (+/-10%) 1ph 50/60Hz | NPT | 3" | Class 2.1.2 | 1250 m³/hr @ 7 barg, 35°C (735 cfm @ 102 psig, 95°F) | -70°C (-100°F) | N/A | ||
| CDASHL170-40G13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 41 to 122 °F | < 75 dBA | 131.0 °F Maximum | 550.0 mm | 67 inch | 1892.0 mm | 825 kg | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 73 to 190 psig | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX | 100 to 240 VAC (±10%) single phase, 50/60Hz | BSPP | 3" | Class 2.2.2 or Class 2.3.2 | 2040 m³/h/hr @ 7 barg, 35°C (1200 cfm @ 102 psig, 95°F) | -40°C (-40°F) or -20°C (-4°F) Option | N/A | ||
| CDASHL170-40N13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50°C<br/>(41 to 122°F) | <75 dB(A) | 55°C (131°F) Maximum | 550 mm<br/>(21.7 inch) | 1701 mm<br/>(67.0inch) | 1892 mm<br/>(74.5 inch) | 825 Kg<br/>(1818 lbs) | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 5 to 13 barg<br/>(73 to 190 psig) | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX | 100-240V (+/-10%) 1ph 50/60Hz | NPT | 3" | Class 2.2.2 or Class 2.3.2 | 2040 m³/hr @ 7 barg, 35°C (1200 cfm @ 102 psig, 95°F) | -40°C (-40°F) or -20°C (-4°F) Option | N/A | ||
| CDASHL170-70G13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50 °C | < 75 dBA | 55.0 °C Maximum | 550.0 mm | 67 inch | 74.5 inch | 825 kg | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 5 to 13 barg | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX | 100 to 240 VAC (±10%) single phase, 50/60Hz | BSPP | 3" | Class 2.1.2 | 1428 m³/h/hr @ 7 barg, 35°C (840 cfm @ 102 psig, 95°F) | -70°C (-100°F) | N/A | ||
| CDASHL170-70N13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50°C<br/>(41 to 122°F) | <75 dB(A) | 55°C (131°F) Maximum | 550 mm<br/>(21.7 inch) | 1701 mm<br/>(67.0inch) | 1892 mm<br/>(74.5 inch) | 825 Kg<br/>(1818 lbs) | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 5 to 13 barg<br/>(73 to 190 psig) | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX055HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX055HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX055HGFX | 100-240V (+/-10%) 1ph 50/60Hz | NPT | 3" | Class 2.1.2 | 1428 m³/hr @ 7 barg, 35°C (840 cfm @ 102 psig, 95°F) | -70°C (-100°F) | N/A | ||
| CDASLE100-40G13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 41 to 122 °F | < 75 dBA | 131.0 °F Maximum | 550.0 mm | 687.0 mm | 64.8 inch | 518 lb | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Vacuum Assisted Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 5 to 13 barg | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX | 460.0 VAC (±10%) three-phase, 60Hz (Option) | BSPP | 2" | Class 2.2.2 or Class 2.3.2 | 408 m³/h/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F) | -40°C (-40°F) or -20°C (-4°F) Option | Vacuum: HLVAP-OL-02-100 (Order Separately) | ||
| CDASLE100-40N13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50°C<br/>(41 to 122°F) | <75 dB(A) | 55°C (131°F) Maximum | 550 mm<br/>(21.7 inch) | 687 mm<br/>(27.0 inch) | 1647 mm<br/>(64.8 inch) | 235 Kg<br/>(518 lbs) | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Vacuum Assisted Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow Heatless (Models CDAS HL 100-170) | 5 to 13 barg<br/>(73 to 190 psig) | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX | 400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option) | NPT | 2" | Class 2.2.2 or Class 2.3.2 | 408 m³/hr @ 7 barg, 35°C (240 cfm @ 102 psig, 95°F) | -40°C (-40°F) or -20°C (-4°F) Option | Vacuum: HLVAP-OL-02-100 (Order Separately) | ||
| CDASLE100-70G13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 41 to 122 °F | < 75 dBA | 131.0 °F Maximum | 21.7 inch | 27 inch | 64.8 inch | 518 lb | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Vacuum Assisted Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170) | 73 to 190 psig | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX | 400.0 VAC (±10%) three-phase, 50Hz (Standard) | BSPP | 2" | Class 2.1.2 | 286 m³/h/hr @ 7 barg, 35°C (168 cfm @ 102 psig, 95°F) | -70°C (-100°F) | Vacuum: HLVAP-OL-02-100 (Order Separately) | ||
| CDASLE100-70N13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50°C<br/>(41 to 122°F) | <75 dB(A) | 55°C (131°F) Maximum | 550 mm<br/>(21.7 inch) | 687 mm<br/>(27.0 inch) | 1647 mm<br/>(64.8 inch) | 235 Kg<br/>(518 lbs) | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Vacuum Assisted Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170) | 5 to 13 barg<br/>(73 to 190 psig) | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX | 400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option) | NPT | 2" | Class 2.1.2 | 286 m³/hr @ 7 barg, 35°C (168 cfm @ 102 psig, 95°F) | -70°C (-100°F) | Vacuum: HLVAP-OL-02-110 (Order Separately) | ||
| CDASLE110-40G13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 41 to 122 °F | < 75 dBA | 131.0 °F Maximum | 21.7 inch | 856.0 mm | 1892.0 mm | 696 lb | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Vacuum Assisted Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170) | 5 to 13 barg | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX | 400.0 VAC (±10%) three-phase, 50Hz (Standard) | BSPP | 2" | Class 2.2.2 or Class 2.3.2 | 612 m³/h/hr @ 7 barg, 35°C (360 cfm @ 102 psig, 95°F) | -40°C (-40°F) or -20°C (-4°F) Option | Vacuum: HLVAP-OL-02-110 (Order Separately) | ||
| CDASLE110-40N13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50°C<br/>(41 to 122°F) | <75 dB(A) | 55°C (131°F) Maximum | 550 mm<br/>(21.7 inch) | 856 mm<br/>(33.7 inch) | 1892 mm<br/>(74.5 inch) | 316 Kg<br/>(696 lbs) | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Vacuum Assisted Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170) | 5 to 13 barg<br/>(73 to 190 psig) | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX | 400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option) | NPT | 2" | Class 2.2.2 or Class 2.3.2 | 612 m³/hr @ 7 barg, 35°C (360 cfm @ 102 psig, 95°F) | -40°C (-40°F) or -20°C (-4°F) Option | Vacuum: HLVAP-OL-02-120 (Order Separately) | ||
| CDASLE110-70G13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50 °C | < 75 dBA | 55.0 °C Maximum | 550.0 mm | 856.0 mm | 1892.0 mm | 316 kg | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Vacuum Assisted Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170) | 73 to 190 psig | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX | 400.0 VAC (±10%) three-phase, 50Hz (Standard) | BSPP | 2" | Class 2.1.2 | 428 m³/h/hr @ 7 barg, 35°C (252 cfm @ 102 psig, 95°F) | -70°C (-100°F) | Vacuum: HLVAP-OL-02-110 (Order Separately) | ||
| CDASLE110-70N13BC | Quote Required | TBD | Parker | Filtration | Gas Separation and Filtration Division EMEA | Gas Separation and Filtration Division EMEA | IP44 | 5 to 50°C<br/>(41 to 122°F) | <75 dB(A) | 55°C (131°F) Maximum | 550 mm<br/>(21.7 inch) | 856 mm<br/>(33.7 inch) | 1892 mm<br/>(74.5 inch) | 316 Kg<br/>(696 lbs) | • General Industrial Manufacturing<br/>• Automotive<br/>• Electronics & Semiconductor Manufacturing | Compressed Air Treatment - Clean Dry Air (CDA) | Compressed Air Dryer with Filtration | Vacuum Assisted Heatless Regeneration | CDAS - Clean Dry Air System - Large Flow, Low Energy Heatless (Models CDAS LE 100-170) | 5 to 13 barg<br/>(73 to 190 psig) | PED 2014/68/EU | <b>Dryer Inlet</b><br/>General Purpose Coalescing Filter<br/>AOPX040HGFX<br/>and<br/>High Efficiency Coalescing Filter<br/>AAPX040HGFX<br/><br/><b>Dryer Outlet</b><br/>General Purpose Dry Particulate Filter<br/>AOPX040HGFX | 400V +/-10% 3PH 50Hz (Standard)<br/>460V +/-10% 3PH 60Hz (Option) | NPT | 2" | Class 2.1.2 | 428 m³/hr @ 7 barg, 35°C (252 cfm @ 102 psig, 95°F) | -70°C (-100°F) | Vacuum: HLVAP-OL-02-130 (Order Separately) |