• Availability & Price
  • Search SKU
Filter by attributes
  • ATEX Specifications Met
  • Connection Type
  • Electrical Requirements
  • Flow Rate
  • ISO Grade
  • Port Size
  • Pressure Dew Point
More Filters...
Filter by manufacturer
Manufacturers

CDAS HL Medium Flow Heatless Compressed Air Dryer System

Picture for category CDAS HL Medium Flow Heatless Compressed Air Dryer System

*PRODUCT IMAGE IS REPRESENTATIVE PROVIDED BY THE MANUFACTURER. DO NOT MAKE BUYING DECISIONS SOLEY BASED ON THE IMAGE. PLEASE VERIFY SPECIFICATIONS MEET YOUR REQUIREMENTS.

Parker's CDAS HL Clean Dry Air Systems provide clean, dry compressed air in accordance with all editions of ISO8573-1, the international standard for compressed air quality. They are energy efficient and can provide pressure dewpoints of -70°C, -40°C or -20°C with flow rates up to 300 m³/hr (177 cfm) @ 7 barg (102 psi g).

Clean, dry air improves production efficiency and reduces maintenance costs and downtime. Many products claim to provide this, however only CDAS HL Clean Dry Air Systems provide the highest levels of dry compressed air with validated performance.

Features
• Energy saving dewpoint dependant switching included as standard*
• 4 Stages of purification
• Treatment of 7 contaminants (9 with optional WS)
• 3rd Party validated performance
• Pre/post filtration included
• ATEX option available, for use in potentially explosive atmospheres
• Corrosion protected
• Full bore internal flow paths

*Not available for ATEX models

Benefits
• High quality compressed air to ISO8573-1 classifications
• -40°C / -70°C PDP also controls microbiological growth
• Improves production efficiency and reduces maintenance costs and downtime
• Dry air means zero corrosion
• Easy and flexible installation

Sizing and Selection
To ensure quoted air purity performance is met, a compressed air dryer must be sized correctly for minimum operating pressure, maximum inlet temperature and maximum inlet flow rate using the correction factors found in the Product Information Sheet.

For more information or a detailed discussion about your specific requirements please contact Parker or an authorised Parker distributor.
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceBrandTechnologyDivisionDivisionWeightNoise LevelSpecifications MetApplicationProduct TypeAmbient TemperatureIngress Protection RatingDepthWidthHeightProduct SeriesIndustryProduct StyleOperating PressureOperating TemperatureConnection TypePort SizeFlow RateISO GradePressure Dew PointATEX Specifications MetElectrical Requirements
CDASHL055-70G16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA84< 75PED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0559.01313.0CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 165 to 50BSPP½ inch70 m³/h @ 7 barg (41 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)YesNone
CDASHL055-70N16AE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA185.0 lb< 75 dBAPED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer131.0IP55 Indoor Use Only19 inch22 inch52 inchCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless58 to 232 psig41 to 122 °FNPT½ inch70 m³/h @ 7 barg (41 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)No85 - 265V 1ph 50/60Hz
CDASHL055-70N16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA84< 75PED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0559.01313.0CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 165 to 50NPT½ inch70 m³/h @ 7 barg (41 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)No24V DC
CDASHL055-70N16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA84< 75PED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0559.01313.0CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 165 to 50NPT½ inch70 m³/h @ 7 barg (41 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)YesNone
CDASHL060-40G16AE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA205 lb< 75 dBAPED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0 mm559.0 mm1510.0 mmCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 16 barg41 to 122 °FBSPP½ inch90 m³/h @ 7 barg (53 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No85 - 265V 1ph 50/60Hz
CDASHL060-40G16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA93< 75PED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0559.01510.0CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 165 to 50BSPP½ inch90 m³/h @ 7 barg (53 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No24V DC
CDASHL060-40G16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA93 kg< 75 dBAPED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer131.0 °F MaximumIP55 Indoor Use Only19 inch559.0 mm1510.0 mmCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 16 barg41 to 122 °FBSPP½ inch90 m³/h @ 7 barg (53 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)YesNone
CDASHL060-40N16AE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA205 lb< 75 dBAPED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer131.0IP55 Indoor Use Only19 inch22 inch1510.0 mmCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless58 to 232 psig41 to 122 °FNPT½ inch90 m³/h @ 7 barg (53 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No85 - 265V 1ph 50/60Hz
CDASHL060-40N16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA93< 75PED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0559.01510.0CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 165 to 50NPT½ inch90 m³/h @ 7 barg (53 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No24V DC
CDASHL060-40N16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA93< 75PED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0559.01510.0CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 165 to 50NPT½ inch90 m³/h @ 7 barg (53 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)YesNone
CDASHL060-70G16AE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA93 kg< 75 dBAPED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer131.0 °F MaximumIP55 Indoor Use Only490.0 mm22 inch59 inchCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless58 to 232 psig41 to 122 °FBSPP½ inch90 m³/h @ 7 barg (53 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)No85 - 265V 1ph 50/60Hz
CDASHL060-70G16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA93< 75PED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0559.01510.0CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 165 to 50BSPP½ inch90 m³/h @ 7 barg (53 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)No24V DC
CDASHL060-70G16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA93< 75PED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0559.01510.0CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 165 to 50BSPP½ inch90 m³/h @ 7 barg (53 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)YesNone
CDASHL060-70N16AE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA93 kg< 75 dBAPED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0IP55 Indoor Use Only19 inch22 inch1510.0 mmCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless58 to 232 psig5 to 50 °CNPT½ inch90 m³/h @ 7 barg (53 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)No85 - 265V 1ph 50/60Hz
CDASHL060-70N16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA93< 75PED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0559.01510.0CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 165 to 50NPT½ inch90 m³/h @ 7 barg (53 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)No24V DC
CDASHL060-70N16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA93< 75PED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0559.01510.0CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 165 to 50NPT½ inch90 m³/h @ 7 barg (53 cfm @ 102 psig)Class 2.1.2-70°C (-100°F)YesNone
CDASHL065-40G16AE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA220 lb< 75 dBAPED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0 mm559.0 mm65 inchCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless58 to 232 psig41 to 122 °FBSPP½ inch110 m³/h @ 7 barg (65 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No85 - 265V 1ph 50/60Hz
CDASHL065-40G16DE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA100< 75PED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer55.0 °C MaximumIP55 Indoor Use Only490.0559.01660.0CDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 165 to 50BSPP½ inch110 m³/h @ 7 barg (65 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No24V DC
CDASHL065-40G16PP
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA220 lb< 75 dBAPED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer131.0 °F MaximumIP55 Indoor Use Only490.0 mm22 inch65 inchCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless4 to 16 barg5 to 50 °CBSPP½ inch110 m³/h @ 7 barg (65 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)YesNone
CDASHL065-40N16AE
Quote Required
TBD
ParkerFiltrationGas Separation and Filtration Division EMEAGas Separation and Filtration Division EMEA220 lb< 75 dBAPED 2014/68/EU Fluid Group IICompressed Air ApplicationsCompressed Air Dryer131.0IP55 Indoor Use Only490.0 mm22 inch65 inchCDASIndustrial Manufacturing Equipment<br/> Food & Beverage<br/>Automotive<br/> Electronics<br/> Pharmaceuticals<br/> Medical & DentalHeatless58 to 232 psig41 to 122 °FNPT½ inch110 m³/h @ 7 barg (65 cfm @ 102 psig)Class 2.2.2 or Class 2.3.2-40°C (-40°F) or -20°C (-4°F)No85 - 265V 1ph 50/60Hz