Parker’s cavity plugs fit all industry standard 8, 10, 12, and 16 size cavities. These plugs function more than just a port plug and can be used in place of any valve that fits in those industry standard cavities. Parker’s cavity plugs can be configured to either block all ports completely or reroute flow to the appropriate ports via several internal spool design options. These valves are ideal for commonizing manifolds across several machine platforms where certain machines may or may not require specific valves and functionality. Cavity plugs can simply replace unused cavities were valves have been removed.

Markets:
• Miscellaneous Industrial
• Miscellaneous Mobile

Features/Benefits:
• High pressure rating
• 4 Sizes available
• Several flow options

Applications:
• Blocking a cavity
• Rerouting flow
Read More...
View as Grid List
Sort by
Display per page
ActionPart No.AvailabilityPartner AvailablePriceUOMMaximum Operating PressureValve MaterialCavity SizeFlow RateNumber of PositionsWeightMinimum Operating TemperatureConfigurationOperating TemperatureMaximum Operating TemperatureInstallation TorqueDivisionMaximum Flow RateBody MaterialDivisionActuation TypeSeal MaterialFor Fluid TypeNumber of PositionsSeal MaterialType/ConfigurationCavity Size
P12-2
Quote Required
TBD
5000 psiAll parts steel. All operating parts hardened steelC12n/a2 way0.29 kg-30 °FAll ports blocked-34 to +121 °C+250 °F131 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aNitrileMineral-based or synthetic hydraulic fluids2 wayNitrileAll ports blockedC12
P12-2V
Quote Required
TBD
5000 psiAll parts steel. All operating parts hardened steelC12n/a2 way0.65 lb-15 °FAll ports blocked-15 to +400 °F+204 °C96 lb-ftHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aFluorocarbonMineral-based or synthetic hydraulic fluids2 wayFluorocarbonAll ports blockedC12
P12-3
Quote Required
TBD
350 barAll parts steel. All operating parts hardened steelC12n/a3 way0.75 lb-34 °CAll ports blocked-30 to +250 °F+121 °C131 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aNitrileMineral-based or synthetic hydraulic fluids3 wayNitrileAll ports blockedC12
P12-3A
Quote Required
TBD
350 barAll parts steel. All operating parts hardened steelC12n/a3 way0.75 lb-34 °CPort 3 blocked-34 to +121 °C+121 °C96 lb-ftHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aNitrileMineral-based or synthetic hydraulic fluids3 wayNitrilePort 3 blockedC12
P12-3AV
Quote Required
TBD
5000 psiAll parts steel. All operating parts hardened steelC12n/a3 way0.34 kg-26 °CPort 3 blocked-26 to +204 °C+204 °C131 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aFluorocarbonMineral-based or synthetic hydraulic fluids3 wayFluorocarbonPort 3 blockedC12
P12-3B
Quote Required
TBD
5000 psiAll parts steel. All operating parts hardened steelC12n/a3 way0.34 kg-30 °FPort 2 blocked-30 to +250 °F+250 °F131 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aNitrileMineral-based or synthetic hydraulic fluids3 wayNitrilePort 2 blockedC12
P12-3BV
Quote Required
TBD
350All parts steel. All operating parts hardened steelC12n/a3 way0.75-15Port 2 blocked-15 to +400+40096Hydraulic Systems Divisionn/an/aHydraulic Valve Systems Divisionn/aFluorocarbonMineral-based or synthetic hydraulic fluids3 wayFluorocarbonPort 2 blockedC12
P12-3C
Quote Required
TBD
350 barAll parts steel. All operating parts hardened steelC12n/a3 way0.75 lb-34 °CPort 1 blocked-30 to +250 °F+250 °F131 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aNitrileMineral-based or synthetic hydraulic fluids3 wayNitrilePort 1 blockedC12
P12-3CV
Quote Required
TBD
350 barAll parts steel. All operating parts hardened steelC12n/a3 way0.34 kg-15 °FPort 1 blocked-15 to +400 °F+204 °C131 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aFluorocarbonMineral-based or synthetic hydraulic fluids3 wayFluorocarbonPort 1 blockedC12
P12-3V
Quote Required
TBD
5000 psiAll parts steel. All operating parts hardened steelC12n/a3 way0.34 kg-15 °FAll ports blocked-15 to +400 °F+204 °C131 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aFluorocarbonMineral-based or synthetic hydraulic fluids3 wayFluorocarbonAll ports blockedC12
P16-2
Quote Required
$155.25
EA5000 psiAll parts steel. All operating parts hardened steelC16n/a2 way0.34 kg-30 °FAll ports blocked-34 to +121 °C+250 °F235 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aNitrileMineral-based or synthetic hydraulic fluids2 wayNitrileAll ports blockedC16
P16-2V
Quote Required
TBD
350 barAll parts steel. All operating parts hardened steelC16n/a2 way0.75 lb-15 °FAll ports blocked-26 to +204 °C+400 °F235 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aFluorocarbonMineral-based or synthetic hydraulic fluids2 wayFluorocarbonAll ports blockedC16
P16-3
Quote Required
TBD
350 barAll parts steel. All operating parts hardened steelC16n/a3 way0.34 kg-30 °FAll ports blocked-34 to +121 °C+121 °C235 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aNitrileMineral-based or synthetic hydraulic fluids3 wayNitrileAll ports blockedC16
P16-3A
Quote Required
TBD
5000 psiAll parts steel. All operating parts hardened steelC16n/a3 way0.75 lb-30 °FPort 3 blocked-30 to +250 °F+121 °C235 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aNitrileMineral-based or synthetic hydraulic fluids3 wayNitrilePort 3 blockedC16
P16-3AV
Quote Required
TBD
5000All parts steel. All operating parts hardened steelC16n/a3 way0.75-15Port 3 blocked-15 to +400+400173Hydraulic Systems Divisionn/an/aHydraulic Valve Systems Divisionn/aFluorocarbonMineral-based or synthetic hydraulic fluids3 wayFluorocarbonPort 3 blockedC16
P16-3B
Quote Required
TBD
5000 psiAll parts steel. All operating parts hardened steelC16n/a3 way0.34 kg-34 °CPort 2 blocked-34 to +121 °C+121 °C235 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aNitrileMineral-based or synthetic hydraulic fluids3 wayNitrilePort 2 blockedC16
P16-3BV
Quote Required
TBD
5000All parts steel. All operating parts hardened steelC16n/a3 way0.75-15Port 2 blocked-26 to +204+400235Hydraulic Systems Divisionn/an/aHydraulic Valve Systems Divisionn/aFluorocarbonMineral-based or synthetic hydraulic fluids3 wayFluorocarbonPort 2 blockedC16
P16-3C
Quote Required
TBD
350 barAll parts steel. All operating parts hardened steelC16n/a3 way0.34 kg-30 °FPort 1 blocked-34 to +121 °C+250 °F235 NmHydraulic Systems Divisionn/an/aHydraulic Cartridge Systems Divisionn/aNitrileMineral-based or synthetic hydraulic fluids3 wayNitrilePort 1 blockedC16
P16-3CV
Quote Required
TBD
350All parts steel. All operating parts hardened steelC16n/a3 way0.75-15Port 1 blocked-26 to +204+400173Hydraulic Systems Divisionn/an/aHydraulic Valve Systems Divisionn/aFluorocarbonMineral-based or synthetic hydraulic fluids3 wayFluorocarbonPort 1 blockedC16
P16-3V
Quote Required
TBD
5000All parts steel. All operating parts hardened steelC16n/a3 way0.75-15All ports blocked-26 to +204+400173Hydraulic Systems Divisionn/an/aHydraulic Valve Systems Divisionn/aFluorocarbonMineral-based or synthetic hydraulic fluids3 wayFluorocarbonAll ports blockedC16